Overview
- 4-pole triplex block configuration (#4, #4, #4 conductors) with full neutral assembly
- 500-pound breakaway force for controlled fault isolation
- Includes two pin terminals, one neutral pin terminal, SSL link kit, and Flood-Seal insulating rockets
- Compatible with standard pin-type insulators for overhead distribution systems
- Designed for overhead line maintenance, fault detection, and temporary bypass operations
Specifications
Application | Mechanical breakaway link separates service at the pole to prevent damage to utility equi[ment and customer premises |
Insulation | Yes |
Special Features | Crew Safety - The correction is made well below the high-voltage bushings, making it safer for crews to work during a storm outage. Downed-Line Safety - separates at the pole not the weatherhead. The line always comes down de-energized. Quick restoration of power. Simply replace the mechanical breakaway link and reinsert the contacts |
Type | Storm-Safe Pin Kits |
Wire Size | #4 AWG |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.8900 L |
Package Weight (Metric) | 0.4040 kg |

SSS 4 K
Storm Safe Pin Kit, # 4 ASCR - CPT, Aluminum and Copper. Contains Pin Terminal, Female Connector, Insulating Rocket, Insulating Cap and Silicone Grease.
RA48V
Polycarbonate Insulated Female Disconnect Terminal, Wire Range 0.5-1.5 millimeters squared, Tab Size 4.8mm x 0.5mm
RB48
Polycarbonate Insulated Female Disconnect Non-Brazed with Support Sleeve Wire Range 1.5-2.5 millimeters squared Tab Size 4.8 x .5 mm
ABC 500-22
Aluminum Set-Screw Bar Pedestal Connectors - Double-Row Bar, cable range 6-500, length 2-1/16 inch, width 2-3/4 inch, boot no. FB 33, outlets 4
ABCK 6600 CK W/7191
Aluminum Lay-In Pedestal Connector Kit, #2-600 kcmil, Aluminum-Copper, (4) Six Conductor Connectors, (24) Keepers and (24) Tin-Plated Aluminum Set Screws, (3) Black PVC Boots and (1) Single Outlet Lug, Contains Oxide Inhibiting Compound and is Stretch Wrapped for shipping. 8.915 inch x 1.25 inch x 1.608 inch.
ABC 4350 BB 10YW
Aluminum Set Screw Bar Pedestal Connector, Dual Rated, ABC Series, In-Line Bar, Conductor Range #12-350, 4 Outlets, BB 10 Yellow Boot
ABCK 61000 MH
Aluminum Lay In Pedestal Connector, 6 Positions, 2-Holes per Conductor, Cable Size 1/0-1000 MCM, Dual Rated for Aluminum and Copper. 11.546 inch longFrequently Asked Questions
What conductor sizes does SSP 4 FN 500 K support?
The SSP 4 FN 500 K pin kit supports #4, #4, #4 ACSR for the triple block and features a full neutral assembly.
What is the breakaway force for SSP 4 FN 500 K?
The SSP 4 FN 500 K pin kit has a breakaway force of 500 lbs.
What conductor sizes does SSP 4 FN 500 K support?
The SSP 4 FN 500 K pin kit supports #4, #4, #4 ACSR for the triple block and features a full neutral assembly.
What is the breakaway force for SSP 4 FN 500 K?
The SSP 4 FN 500 K pin kit has a breakaway force of 500 lbs.
What is the breakaway force for SSP 4 FN 500 K?
The SSP 4 FN 500 K pin kit has a breakaway force of 500 lbs.
What conductor sizes does SSP 4 FN 500 K support?
The SSP 4 FN 500 K pin kit supports #4, #4, #4 ACSR for the triple block and features a full neutral assembly.
What is the breakaway force for SSP 4 FN 500 K?
The SSP 4 FN 500 K pin kit has a breakaway force of 500 lbs.
What conductor sizes does SSP 4 FN 500 K support?
The SSP 4 FN 500 K pin kit supports #4, #4, #4 ACSR for the triple block and features a full neutral assembly.
How many SSP pin kits are needed for multi-service base kits?
A two-service base kit (SS 2 K) requires two SSP pin kits, and a three-service base kit (SS 3 K) requires three SSP pin kits.
What is the primary benefit of the Storm-Safe system?
The system ensures lines come down de-energized at the pole during an event, preventing safety hazards and damage to customer premises or utility equipment.
How to Install the SSP Series Service Entrance Disconnect System
This guide provides step-by-step instructions for the safe installation and wiring of the SSP Series Multiple Service Kit, including connecting service and load-side cables to the contact block. Ensure all safety precautions are followed, as installation must be performed by trained installers in accordance with all applicable electrical codes, standards, and safety rules.
Estimated time: 1h 30m
Tools needed:
Insulated gloves rated to the appropriate voltage, Safety cutting device, Crimping tool, Appropriate crimping dies, 5/8 inch crimping die, Torque wrench (for 480 in-lb), Wrench (for U-bolt nuts)
Supplies needed:
Breakaway link, Neutral wedge clamp, Pole hardware, U-Bolt, Service cables, CS 2011 Flood-Seal insulating rockets, Silicone grease, Compression lugs, Contact block, Neutral lug, Load-side triplex service cable, CS 2277 Flood-Seal insulating rockets, Pin Connectors
- Disconnect Power and Secure Service Drop
Disconnect the power cables from the transformer or feed. Secure the service drop to prevent accidental re-energization. Always follow standard safety practices when working on energized circuits.
- Install Breakaway Link
Open the neutral wedge clamp. Install the breakaway link between the wedge clamp and the pole hardware. Tighten the service drop as required.
- Mount the Contact Block
Install the contact block to the eyebolt using the included U-Bolt. Tighten the nuts from the pole side of the contact block to secure it firmly.
- Prepare Service Cables
Cut the service cables from the transformer or feed. If the cables are not large enough for multiple loads, replace them with the proper size. Ensure the feed cables have some slack when their ends are held alongside the pads to allow the contact block to swing.
- Prepare Hot Legs with Insulating Rockets and Lugs
Cut two CS 2011 Flood-Seal Insulating rockets at the appropriate ring using an approved safety cutting device. Install these rockets on the two hot legs, applying silicone grease to the cables to ease installation. Crimp appropriately sized compression lugs onto the three cables using an appropriate crimping tool and listed dies.
- Terminate Neutral and Hot Legs on Contact Block
First, terminate the neutral lug onto the center pad of the contact block, ensuring the barrel is over the pad as shown in the diagram. Torque the connection to 480 in-lb. Next, install one of the hot (energized) legs as per the neutral leg termination. Slide a Flood-Seal insulating rocket over this connection. Repeat for the other hot leg. Note: A rocket is not required for the Neutral leg.
- Position Load-Side Triplex Service Cable
Position the load-side triplex service cable alongside the Storm-Safe contact block. Ensure the neutral conductor is 6 to 12 inches longer than the phase conductor to ensure the neutral pulls out last in a storm event.
- Prepare Load-Side Hot Conductors with Insulating Rockets
Cut two CS 2277 Flood-Seal insulating rockets at the appropriate ring using an approved safety cutting device. Install these rockets on the two load-side hot conductors.
- Prepare Load-Side Cables and Crimp Pin Connectors
Position the load-side cables alongside the pin connectors and mark them at 1/8 inch beyond the knurl mark. Mark and strip the cable. In a reduced neutral, determine which is the neutral socket. Crimp the Pin Connectors onto the conductors using a 5/8 inch or equivalent die as shown on the crimp body. Fill the crimp body between the knurl marks with crimps spaced 1/8 inch apart (five crimps with a 5/8 inch die).
- Insert Neutral Pin
Insert the Neutral Pin into the contact block. The neutral is the center row and is identified with a white marker. The neutral body is oversized and cannot be inserted into a hot leg tower.
- Insert Hot Leg Pins and Insulating Rockets
Insert one of the hot leg pins into one of the outer contact block towers. Slide the Flood-Seal insulating rockets over the towers. Do not use silicone grease for these rockets. Repeat this process for the other services.
- Reconnect Power
Reconnect the transformer or feed to restore power to the system. Ensure the connection is not under load.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.