ABB - Installation Products SS1 1/0 FN 750K - Storm-Safe Breakaway Service Entrance Kits, triplex block - 1/0,1/0,1/0 ACSR, neutral assembly - full neutral, breakaway force - 750 Pound Break Force

ABB Installation Products SS1 1/0 FN 750K Storm-Safe Breakaway Service Entrance Kits, triplex block - 1/0,1/0,1/0 ACSR, neutral…

UPC: 783786753451


Documents & Media
BrochureInstallation InstructionsManufacturer Product Website

Contact for Pricing

Minimum Qty: 12

Multiplier: 12

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Storm-Safe Breakaway Service Entrance Kit, SKU SS1 1/0 FN 750K, is engineered for reliable service entrance connections. This kit features a triplex block designed for 1/0, 1/0, 1/0 ACSR conductors, ensuring robust electrical connectivity. The full neutral assembly provides a complete and secure connection point. A critical safety feature is the breakaway mechanism, rated for a 750-pound break force. This breakaway capability is designed to mitigate damage to the service entrance conductors and associated equipment during severe weather events or accidental impacts, such as a vehicle striking a service drop. By intentionally disconnecting at a predetermined force, the kit helps prevent catastrophic failures and reduces the potential for widespread power outages. The ABB Installation Products brand signifies a commitment to quality and functionality in electrical distribution and utility applications. This kit is suitable for utility service entrance installations where conductor protection and system integrity are paramount. The UNSPSC code for this product is 39121447, categorizing it under electrical connectors and fittings. Key Specifications: - Conductor Size: 1/0, 1/0, 1/0 ACSR - Neutral Assembly: Full Neutral - Breakaway Force: 750 Pound Break Force - Manufacturer: ABB - Installation Products - SKU: SS1 1/0 FN 750K
  • Triplex block for 1/0, 1/0, 1/0 ACSR conductors
  • Full neutral assembly for complete connection
  • 750 Pound Break Force breakaway mechanism for safety
  • Mitigates damage during severe weather or impacts
  • ABB Installation Products quality and reliability

Specifications

Application
Mechanical breakaway link separates service at the pole to prevent damage to utility equi[ment and customer premises
Insulation
Yes
Special Features
Crew Safety - The correction is made well below the high-voltage bushings, making it safer for crews to work during a storm outage. Downed-Line Safety - separates at the pole not the weatherhead. The line always comes down de-energized. Quick restoration of power. Simply replace the mechanical breakaway link and reinsert the contacts
Type
Storm-Safe Service Entrance Disconnect Pin Kits
Wire Size
1/0 ACSR AWG
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.4600 L
Package Weight (Metric)
0.6620 kg
Storm-Safe Pin Kits, triplex block - 1/0,1/0,1/0 ACSR, neutral assembly - full neutral, breakaway force - 750 pounds break force

SSP 1/0 FN 750K

Storm-Safe Pin Kits, triplex block - 1/0,1/0,1/0 ACSR, neutral assembly - full neutral, breakaway force - 750 pounds break force
Storm-Safe Breakaway Service Entrance Kits, triplex block - 1/0,1/0,1/0 ACSR, neutral assembly - full neutral, breakaway force - 500 Pound Break Force

SS1 1/0 FN 500K

Storm-Safe Breakaway Service Entrance Kits, triplex block - 1/0,1/0,1/0 ACSR, neutral assembly - full neutral, breakaway force - 500 Pound Break Force
Storm-Safe Breakaway Service Entrance Kits, triplex block - 2,2,2, neutral assembly - full neutral, breakaway force - 500 Pound Break Force

SS1 2 FN 500K

Storm-Safe Breakaway Service Entrance Kits, triplex block - 2,2,2, neutral assembly - full neutral, breakaway force - 500 Pound Break Force
Storm-Safe Breakaway Service Entrance Kits, triplex block - 2,2,2, neutral assembly - full neutral, breakaway force - 750 Pound Break Force

SS1 2 FN 750K

Storm-Safe Breakaway Service Entrance Kits, triplex block - 2,2,2, neutral assembly - full neutral, breakaway force - 750 Pound Break Force
Storm-Safe Breakaway Service Entrance Kits, triplex block - 1/0,1/0,2, neutral assembly - reduced neutral, breakaway force - 500 Pound Break Force

SS1 1/0 RN 500K

Storm-Safe Breakaway Service Entrance Kits, triplex block - 1/0,1/0,2, neutral assembly - reduced neutral, breakaway force - 500 Pound Break Force
Storm-Safe Breakaway Service Entrance Kits, triplex block - 2,2,4, neutral assembly - reduced neutral, breakaway force - 500 Pound Break Force

SS1 2 RN 500K

Storm-Safe Breakaway Service Entrance Kits, triplex block - 2,2,4, neutral assembly - reduced neutral, breakaway force - 500 Pound Break Force
Storm-Safe Breakaway Service Entrance Kits, triplex block - 4,4,4, neutral assembly - full neutral, breakaway force - 500 Pound Break Force

SS1 4 FN 500K

Storm-Safe Breakaway Service Entrance Kits, triplex block - 4,4,4, neutral assembly - full neutral, breakaway force - 500 Pound Break Force
Storm-Safe Breakaway Service Entrance Kits, triplex block - 4,4,4, neutral assembly - full neutral, breakaway force - 750 Pound Break Force

SS1 4 FN 750K

Storm-Safe Breakaway Service Entrance Kits, triplex block - 4,4,4, neutral assembly - full neutral, breakaway force - 750 Pound Break Force

Frequently Asked Questions

What is the main purpose of the Storm-Safe system?

The Storm-Safe system ensures power lines de-energize safely at the pole during an event, minimizing damage to premises and utility equipment.

What conductor sizes are compatible with SS1 1/0 FN 750K?

The SS1 1/0 FN 750K kit is designed for 1/0, 1/0, 1/0 ACSR conductors with a full neutral assembly.

Where are Blackburn Storm-Safe disconnects assembled?

Blackburn Storm-Safe service entrance disconnects are assembled and shipped from Ormond Beach, Florida.

What is the purpose of the Flood-Seal insulating rockets?

The external Flood-Seal insulating rockets are designed to seal the entire Storm-Safe system from the elements.

What is included in an SSL link kit?

An SSL link kit consists of a breakaway link and a bail.

What components are included in a single-service breakaway kit?

A single-service kit includes two sockets, one neutral socket, two pin terminals, one neutral pin terminal, an SSL link kit, two Flood-Seal splice covers, and one Flood-Seal insulating rocket.

What is the breakaway force for the SS1 1/0 FN 750K kit?

The SS1 1/0 FN 750K single-service kit has a breakaway force of 750 lbs.

What industry specifications does the Storm-Safe system meet?

The Blackburn Storm-Safe service entrance breakaway disconnect system meets ANSI C119.4-2004 specifications.

What conductor materials are compatible with Storm-Safe?

The Blackburn Storm-Safe system is dual rated for use with both aluminum and copper conductors.

What are the key features of the Storm-Safe system?

Key features include an internal O-ring for moisture prevention, external Flood-Seal insulating rockets, and dual rating for aluminum and copper conductors.

How to Install the SS1 Series Service Entrance Disconnect System

This guide provides step-by-step instructions for trained installers to safely install and connect the SS1 Series Single Service Kit, including cable preparation, connector crimping, and final power reconnection.

Estimated time: 2h

Tools needed:

Approved safety cutting device, Crimp die (5/8 or equivalent), Insulated gloves rated to appropriate voltage, Wire strippers, Standard electrical tools

Supplies needed:

Flood-Seal® caps, CS 2277 Flood-Seal® insulating rocket (short cover), CSN 2277 Flood-Seal® Insulating rockets (long covers), Silicone grease, Neutral wedge clamp, Breakaway link, Pin connectors, Socket connectors, Neutral Pin, Neutral Socket, Hot Load-Side Pin, Hot Feed-Side Socket, Flood Seal® Insulating Rocket

  1. Disconnect Service Power

    Disconnect the power cables from the transformer or feed and secure the service drop. Ensure all safety precautions are followed, including wearing appropriate insulated gloves. Danger of electric shock is present; installation must be performed by trained installers.

  2. Install Neutral Breakaway Link

    Open the neutral wedge clamp and install the breakaway link between the wedge clamp and pole hardware. Tighten the service drop as required.

  3. Trim Service Cables

    Cut the service cables from the transformer or feed. Trim the load-side cables so that the neutral is 6 to 12 inches longer than the hot (energized) cables. This ensures the neutral disconnects last in a storm event.

  4. Prepare Hot Feed-Side Cables

    Cut two CSN 2277 Flood-Seal® Insulating rockets (long covers) at the appropriate ring using an approved safety cutting device. Install them on the feed side of the hot cables. Apply silicone grease to the cables to ease installation.

  5. Prepare Load-Side and Neutral Cables

    Cut two Flood-Seal® caps at the appropriate ring with an approved safety cutting device and install them on the load-side of the hot cables. Apply silicone grease to the cables to ease installation. Cut one CS 2277 Flood-Seal® insulating rocket (short cover) and install it on the feed side of the neutral cable, applying silicone grease to ease installation.

  6. Crimp Feed-Side Socket Connectors

    Position the feed-side cables alongside the sockets and mark at 1/8 inch beyond the knurl mark (approximately 1 5/8 inches). Mark and strip the cable. In a reduced neutral, determine which is the neutral socket. Crimp the socket connectors onto the feed-side conductors using a 5/8 or equivalent die shown on the crimp body. Fill the crimp body between the knurl marks with crimps spaced 1/8 inch apart (five crimps with a 5/8 die).

  7. Crimp Load-Side Pin Connectors

    Position the load-side cables alongside the pins and mark at 1/8 inch beyond the knurl mark (approximately 1 5/8 inches). Mark and strip the cable. In a reduced neutral, determine which is the neutral socket. Crimp the pin connectors onto the load-side conductors with a 5/8 or equivalent die shown on the crimp body. Fill the crimp body between the knurl marks with crimps spaced 1/8 inch apart (five crimps with a 5/8 die).

  8. Connect Neutral Pin and Socket

    Insert the Neutral Pin into the Neutral Socket. Slide the Flood Seal® Insulating Rocket down over the mated connector.

  9. Connect First Hot Conductor

    Insert one Hot Load-Side Pin into a Hot Feed-Side Socket. Slide the cover and cap together.

  10. Connect Second Hot Conductor

    Repeat the connection process from Step 9 for the other hot feed-side.

  11. Reconnect Power

    Reconnect the transformer or feed. Ensure all connections are secure and verify proper operation according to local codes. Connection to the service may be made with the contact block energized, but it must not be under load.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.