ABB - Installation Products R2T28J2-T1230-B2 - Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum Barrel for AL Condutor only with Copper Wire Lead #2-4/0, Conductor Code - 230 -Stranded or Compressed #1 Compact or Solid 1/0. Cable Mounting Bracket - B2 - Stainless Steel - Size 1.10 inch - 1.50 inch.

ABB Installation Products R2T28J2-T1230-B2 Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed…

UPC: 783786517381


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination, SKU R2T28J2-T1230-B2, is engineered for outdoor 28kV applications, meeting industry standards for medium-voltage cable terminations. This termination is specifically designed for Concentric Neutral and Jacketed Concentric Neutral cable types, ensuring compatibility with common distribution cable constructions. It accommodates an insulation range of 0.84 inches to 1.38 inches, providing flexibility for various cable diameters and insulation thicknesses. The connector features an aluminum barrel, exclusively for aluminum conductors, and includes a copper wire lead suitable for conductor sizes #2 to 4/0 AWG, enabling secure electrical connections. The conductor code 230 specifies compatibility with stranded or compressed #1 AWG compact or solid 1/0 AWG conductors, covering a range of common conductor configurations. The included B2 cable mounting bracket is constructed from stainless steel, designed for cable diameters between 1.10 inches and 1.50 inches, providing secure and corrosion-resistant mounting in outdoor environments. This termination system offers a reliable solution for connecting and insulating medium-voltage power cables, ensuring long-term performance and safety in utility and industrial applications. UNSPSC Code: 26121648.
  • Outdoor 28kV termination for Concentric Neutral/Jacketed Concentric Neutral cables
  • Insulation range: 0.84 inch - 1.38 inch
  • Aluminum barrel connector for AL conductors only
  • Copper wire lead for #2 - 4/0 AWG conductors
  • Stainless steel mounting bracket (B2) for 1.10 - 1.50 inch cable diameters

Specifications

Application
Cable Termination, Outdoor Application, 28kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
#1 STR AWG , #1 COMPR AWG , 1/0 SOL AWG , 1/0 COMPT AWG
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
28 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 230 -Stranded or Compressed #1 Compact or Solid 1/0.

R2T28J2-N0230

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 230 -Stranded or Compressed #1 Compact or Solid 1/0.
28 kv, Ranger2, Outdoor Cable Termination, Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .84-1.38 inch (21-35mm), Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code 220 - Stranded or Compressed #2, Compact or Solid #1. Stainless Steel Cable Mounting Bracket .80-1.25 inch (20-32mm).

R2T28J2H0220-B1

28 kv, Ranger2, Outdoor Cable Termination, Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .84-1.38 inch (21-35mm), Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code 220 - Stranded or Compressed #2, Compact or Solid #1. Stainless Steel Cable Mounting Bracket .80-1.25 inch (20-32mm).
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral/Jacketed Concentric Neutral Cable, Aluminum 2-Hole Spade #2-1250kcmil, Stranded or Compressed 1000 . - Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm). L

R2T28J4-N0410-B4L

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral/Jacketed Concentric Neutral Cable, Aluminum 2-Hole Spade #2-1250kcmil, Stranded or Compressed 1000 . - Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm). L
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

R2T28J4-N0330-B3

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #2 /Compact or Solid #1

R2T28J2-T0220

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #2 /Compact or Solid #1
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for 1250 kcmil

R2T28J2-N0300

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for 1250 kcmil
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed #2 /Compact or Solid #1, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

R2T28J2-N0300-B3

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed #2 /Compact or Solid #1, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 4/0 /Compact or Solid 250, Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch

R2T28J2-N0270-B2

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 4/0 /Compact or Solid 250, Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch

Frequently Asked Questions

Are there specific installation instructions for the R2T28 termination?

Yes, specific installation instructions are available: IS-1134 for R2T28J, IS-1135 for R2T28M, and IS-1136 for R2T28L.

What is the voltage rating of the R2T28 termination?

The R2T28 termination has a voltage rating of 25/28 kV.

What cable insulation diameters does the R2T28 cover?

The R2T28 termination covers cable insulation diameters from 0.84 in (21.3 mm) to 2.10 in (53 mm).

What cable sizes are compatible with the R2T28 termination?

The R2T28 termination accommodates cable sizes from #2 AWG through 1250 kcmil.

What is the IEEE classification for this outdoor termination?

The R2T28 outdoor termination has an IEEE Classification of Class 1A.

How many sheds does the 25/28kV outdoor model have?

The 25/28kV outdoor model of the R2T28 termination features six sheds.

What is the maximum operating altitude for the R2T28 termination?

The R2T28 termination has a maximum operating altitude range of 3300 feet (1005 m).

What is the ambient temperature range for the R2T28 termination?

The R2T28 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the power system frequency range for this termination?

The R2T28 termination is designed for a power system frequency range of 48 to 62 Hz.

Are there specific installation instructions for the R2T28 termination?

Yes, specific installation instructions are available: IS-1134 for R2T28J, IS-1135 for R2T28M, and IS-1136 for R2T28L.

How to Install the R2T28J2 Cable Termination

This guide provides step-by-step instructions for the safe and proper installation of the R2T28J2 Ranger 2 Cable Termination for 28kV indoor/outdoor applications on concentric and jacketed concentric neutral cables. Ensure all safety precautions are followed.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Approved solvent, Aluminum oxide abrasive (grit 120 or finer, optional)

Supplies needed:

Silicone Rubber Termination (kit contents), Silicone Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Gloves, Connector (optional, but typically required), Cable Support Bracket (optional), Vinyl tape or binding wire, Silicone grease

  1. Prepare the Cable for Termination

    DANGER: Ensure all apparatus is de-energized during installation. Verify the cable size is compatible with the R2T28J2 kit. Train the cable into position and cut it to the required length, allowing sufficient neutral wire length for grounding. Prepare the cable according to the specified dimensions: 10.5 inches (270mm) for Dimension A (insulation shield cutback), 2 inches (50mm) for the cable jacket, and account for terminal lug depth plus additional exposed conductor distance for aluminum lugs (e.g., 2-1/4 inches or 57mm for barrel depth plus 'X' for growth). Using 50% stretch, wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end, cutting it flush without overlap. This mastic also serves as a marker. Bend the neutral wires back over the mastic and press them in. Secure the neutral wires to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the previously applied mastic, using 50% stretch and cutting flush. Wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4 inch (6mm) dimension.

  2. Install the Lug or Connector

    If using a lug that does not fit through the termination core, clean the cable insulation and slide the termination body onto the cable before installing the lug. Do not remove the core at this stage. Position the connector or lug onto the prepared conductor and crimp it according to the manufacturer's directions. IMPORTANT: Do not crimp the last 1/4 to 3/8 inch of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.

  3. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent. CAUTION: Do not allow the solvent to touch the semi-con insulation shield. If abrasive cleaning is necessary, use it only on the insulation, not on the semi-con insulation shield. Use only aluminum oxide abrasive, grit 120 or finer, and be careful not to reduce the cable insulation diameter below the kit's allowed range.

  4. Install the Termination Body

    IMPORTANT: Create a track-resistant moisture seal by wrapping a band of gray silicone rubber tape (from the kit) around the base of the terminal lug. If the barrel diameter is equal to or greater than the cable primary insulation, use no more than two layers. If the barrel diameter is smaller, build up the tape band to equal the insulation diameter. Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step at the semi-con cut-off. For terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom of the termination. Slide the termination body onto the cable, aligning the terminator with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted up to the leading edge of the mastic seal. CAUTION: Do not push or pull on the termination assembly while removing the core material. Apply a thin film of silicone lubricant to the skirt and mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape. Overlap the termination insulator by approximately 1 inch and extend the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration.

  5. Ground and Final Check

    Twist the concentric neutral wires together and connect them securely to the system ground. Confirm that the High-K step (the overlap of the termination insulator over the cable semi-con) does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.