Authorized ABB Distributor (Installation Products)
ABB - Installation Products R2T28J2H0220-B1 - 28 kv, Ranger2, Outdoor Cable Termination, Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .84-1.38 inch (21-35mm), Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code 220 - Stranded or Compressed #2, Compact or Solid #1. Stainless Steel Cable Mounting Bracket .80-1.25 inch (20-32mm).

ABB Installation Products R2T28J2H0220-B1 28 kv, Ranger2, Outdoor Cable Termination, Concentric Neutral/Jacketed Concentric…

UPC: 075114287579


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Outdoor Cable Termination (SKU: R2T28J2H0220-B1) is engineered for reliable outdoor power distribution at 28 kV. This termination is specifically designed for concentric neutral and jacketed concentric neutral cable types, ensuring robust performance in demanding environments. It accommodates an insulation range of 0.84 to 1.38 inches (21-35mm), providing flexibility for various cable sizes. The integrated connector is an aluminum 1-hole spade, compatible with conductors ranging from #2 to 500 kcmil. This termination is suitable for stranded or compressed #2 AWG conductors, as well as compact or solid #1 AWG conductors, identified by conductor code 220. A durable stainless steel cable mounting bracket is included, designed to fit cable diameters from 0.80 to 1.25 inches (20-32mm), facilitating secure and stable installation. Manufactured by ABB - Installation Products, this termination is a critical component for overhead and underground power systems requiring dependable cable management and protection. Its construction prioritizes electrical integrity and mechanical strength, essential for long-term operational life in outdoor electrical infrastructure.
  • 28 kV rated outdoor cable termination
  • Suitable for Concentric Neutral/Jacketed Concentric Neutral cables
  • Accommodates insulation range of 0.84-1.38 inches (21-35mm)
  • Aluminum 1-hole spade connector for #2-500 kcmil conductors
  • Includes stainless steel mounting bracket for 0.80-1.25 inch cables

Specifications

Application
Cable Termination, Outdoor Application, 28kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
#2 STR AWG , #2 COMPR AWG , #1 SOL AWG , #1 COMPT AWG
Connection Type
Aluminum 1-Hole Spade connector
Current Rating
#2-500 kcmil
Earthing
Products Includes Their Own Grounding System
Material
Aluminum, Stainless Steel
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Stainless Steel Cable Mounting Bracket (0.80 - 1.25 inch)
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
0.84 - 1.38 inch (21-35mm, cable insulation diameter)
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
28 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 1-Hole Spade #2-500 kcmil, Conductor #2 Stranded/Compressed or #1 Compact/Solid

R2T35M2H0220

Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 1-Hole Spade #2-500 kcmil, Conductor #2 Stranded/Compressed or #1 Compact/Solid
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral/Jacketed Concentric Neutral Cable, Aluminum 2-Hole Spade #2-1250kcmil, Stranded or Compressed 1000 . - Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm). L

R2T28J4-N0410-B4L

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral/Jacketed Concentric Neutral Cable, Aluminum 2-Hole Spade #2-1250kcmil, Stranded or Compressed 1000 . - Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm). L
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

R2T28J4-N0330-B3

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #2 /Compact or Solid #1

R2T28J2-T0220

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #2 /Compact or Solid #1
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for 1250 kcmil

R2T28J2-N0300

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for 1250 kcmil
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed #2 /Compact or Solid #1, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

R2T28J2-N0300-B3

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed #2 /Compact or Solid #1, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 4/0 /Compact or Solid 250, Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch

R2T28J2-N0270-B2

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 4/0 /Compact or Solid 250, Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 280 -Stranded or Compressed 250 Compact or Solid 300.

R2T28J2-N0280

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 280 -Stranded or Compressed 250 Compact or Solid 300.

Frequently Asked Questions

What is the maximum operating voltage for this cable termination?

The ABB Ranger2 outdoor cable termination is rated for 28 kV.

What types of cables can this termination be used with?

This termination is designed for concentric neutral and jacketed concentric neutral cable types.

What is the insulation diameter range for this termination?

The insulation range accommodated by this termination is 0.84 to 1.38 inches (21-35mm).

What conductor sizes does the aluminum spade connector support?

The aluminum 1-hole spade connector supports conductor sizes from #2 to 500 kcmil.

What is the size range for the included cable mounting bracket?

The stainless steel cable mounting bracket is designed for cable diameters of 0.80 to 1.25 inches (20-32mm).

How to Install the R2T28J2 Ranger 2 Cable Termination

This guide provides detailed instructions for the safe and proper installation of the R2T28J2 Ranger 2 Cable Termination for 28kV indoor/outdoor applications, covering cable preparation, lug installation, cleaning, and termination sealing for concentric and jacketed concentric neutral cables.

Estimated time: 1h 30m

Tools needed:

Crimping tool, Wire strippers, Measuring tape, Gloves, Approved solvent, Aluminum oxide abrasive (optional, grit 120 or finer)

Supplies needed:

R2T28J2 Ranger 2 Cable Termination kit (includes silicone rubber termination, lubricant, silicone rubber tape, sealing mastic, gloves), Terminal lug or connector, Cable (concentric or jacketed concentric neutral), Vinyl tape, Binding wire (optional)

  1. Prepare the Cable

    DANGER: Ensure all apparatus is de-energized during installation. This product should only be installed by competent personnel trained in high voltage electrical equipment safety. Failure to follow instructions will result in damage to the product and serious or fatal injury. First, check that the cable size fits within the kit's specified range. Train the cable into position and cut it to the required length, allowing sufficient neutral wire length for grounding connections. Prepare the cable jacket, mastic, and semi-con insulation shield to the specified dimensions, allowing for the depth of the terminal lug. For concentric neutral cables, bend the neutral wires back and secure them as instructed. Apply one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end, using 50% stretch; cut flush without overlapping. Bend the neutral wires back over and press them into the mastic, securing them to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the previously applied mastic, again using 50% stretch and cutting flush. Finally, wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4 inch (6mm) dimension.

  2. Install the Terminal Lug or Connector

    If using a terminal lug or connector that will not fit through the termination core, clean the cable insulation and slide the termination body onto the cable before installing the lug; do not remove the core at this time. Position the connector or lug and crimp it according to the manufacturer's directions, ensuring not to crimp the last 1/4 inch to 3/8 inch of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.

  3. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, taking care not to allow the solvent to touch the semi-con insulation shield. If an abrasive must be used, apply it only to the insulation (not the semi-con insulation shield) and use only aluminum oxide abrasive, grit 120 or finer. Be careful not to reduce the cable insulation diameter below that allowed by the kit.

  4. Install the Termination Body

    Create a track-resistant moisture seal between the termination insulator and the lug/connector using the gray silicone rubber tape provided in the kit. Wrap a band of silicone tape around the base of the terminal lug; if the barrel diameter is equal to or greater than the cable primary insulation, the tape band should not exceed two layers. If the barrel diameter is smaller than the cable primary insulation, use the tape strip to form a tape band equal to the insulation diameter. Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease to fill the step at the semi-con cut-off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Slide the termination body onto the cable, aligning the terminator with the forward edge of the mastic seal. Carefully begin to remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted up to the leading edge of the mastic seal. Do not push or pull on the termination assembly while removing the core material.

  5. Complete Sealing and Grounding

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. With the termination installed, complete the lug area moisture seal using the remaining gray silicone rubber tape. Overlap the termination insulator by approximately 1 inch and extend the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and connect them to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.