ABB Installation Products R2T15J1-T0270 Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12…
UPC: 783786672974
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15 kV Voltage Rating for outdoor medium-voltage applications
- Accommodates 0.64" to 1.12" cable insulation diameter
- Universal aluminum barrel for #2 AWG to 4/0 AWG AL/CU conductors
- Non-tracking silicone housing with four sheds for enhanced creepage
- Shrink-fit technology with pull-down jacket seal for easy installation
Specifications
Application | Cable Termination, Outdoor Application, 15kV |
Cable Type | Concentric Neutral Wire |
Color | Gray |
Conductor Size | 4/0 AWG , 250 kcmil |
Connection Type | Universal Aluminum Barrel with copper wire lead |
Current Rating | 2/0 to 4/0 AWG |
Earthing | Products Includes Their Own Grounding System |
Material | Aluminum, Copper |
Mounting | Product Need to have Cable Holder (not included) |
Number Of Terminals | (1) Single Phase |
Series | Ranger2 |
Size | Cable insulation diameter 0.64 - 1.12 inches |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Outdoor - Ranger2 |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

PCT10270-4
15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - 4/0 Stranded/Compressed, Use for Insulation Diameter Range from .640 to 1.070 inches.
R2T15J1-N0330
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 500 /Compact or Solid 600.
R2T35J2-N0250
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 2/0 /Compact or Solid 3/0
R2T15J1-N0270
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 4/0 Stranded or 250 kcmil Solid
R2T15J1-N0250
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.
R2T35J2-T0270-B3
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead, Stranded or Compressed 4/0 /Compact or Solid 250, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch
R2T35J2-N0230
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed #1 /Compact or Solid 1/0
R2T28M2-N0300
Outdoor Ranger2 Cable Termination. 25/28kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 350 Stranded/Compressed or 400 Compact/SolidFrequently Asked Questions
What is the operating temperature range?
The R2T15 operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What cable sizes does the R2T15 cover?
The R2T15 termination covers cable insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm), accommodating #2 AWG through 1250 kcmil cables.
What cable types are compatible with R2T15?
The R2T15 units accommodate popular XLP and EPR cable types and various shield constructions.
What sizes are available for the R2T15?
The R2T15 termination is available in sizes 1, 2, and 4.
What is the voltage rating of R2T15?
The R2T15 cable termination has a voltage rating of 15 kV.
What is the maximum design voltage to ground?
The maximum design voltage to ground for the R2T15 is 9.5 kV.
What is the coronal extinction voltage?
The coronal extinction voltage for the R2T15 is 13 kV (at 3pC partial discharge).
What is the lightning impulse withstand voltage?
The lightning impulse (BIL Dry 110 Withstand) voltage for the R2T15 is 110 kV Crest.
How many sheds does the R2T15 have?
The R2T15 outdoor model has four sheds.
What is the IEEE classification for R2T15?
The R2T15 outdoor termination has an IEEE Classification of Class 1A.
How to Install 15kV & 28kV Ranger 2 Cable Terminations
This guide provides step-by-step instructions for the safe and proper installation of 15kV and 28kV Ranger 2 Cable Terminations for indoor/outdoor applications on concentric and jacketed concentric neutral cables. Ensure all apparatus is de-energized before starting.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Crimping tool, Approved solvent, Aluminum oxide abrasive (grit 120 or finer, if needed), Measuring tape or ruler
Supplies needed:
Silicone Rubber Termination kit, Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Gloves, Elastimold copper or aluminum lug (or compatible connector), Vinyl tape or binding wire, Silicone grease
- Prepare Cable and Verify Compatibility
DANGER: Ensure all apparatus is de-energized during installation. Verify that the cable size fits within the kit's range as shown in the Termination Selection Chart. Train the cable into position and cut it to the length required for installation, allowing sufficient neutral wire length for grounding connection.
- Prepare Cable Dimensions and Apply Mastic
Prepare the cable using the dimensions shown in the instructions, allowing for the depth of the terminal lug and additional exposed conductor distance for aluminum lugs. Using 50% stretch, carefully wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end. Position the mastic carefully as it serves as a marker for the terminator. Cut the mastic flush, do not overlap.
- Secure Neutral Wires and Apply Second Mastic Seal
Bend the neutral wires back over and press them into the sealing mastic. Secure the neutral wires to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Using 50% stretch, apply a second mastic band over the neutral wires and the previously applied mastic. Cut flush, do not overlap. Wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4 inch (6mm) dimension.
- Install Lug or Connector
If using a lug that will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core at this time). Position the connector/lug and crimp it according to its specific directions. Do not crimp the last 1/4 inch to 3/8 inch of the connector. Remove excess oxide inhibitor and sharp crimp flashings after crimping.
- Clean Cable Insulation and Lug Barrel
Wipe the cable insulation with an approved solvent, ensuring not to allow the solvent to touch the semi-con insulation shield. If an abrasive must be used, apply it only on the insulation (not the semi-con shield), using aluminum oxide abrasive, grit 120 or finer. Be careful not to reduce the cable insulation diameter below that allowed by the kit.
- Apply Silicone Tape and Grease
Wrap a band of gray silicone rubber tape around the base of the terminal lug to create a track-resistant moisture seal between the termination insulator and the lug/connector. If the barrel diameter is smaller than the cable primary insulation, use tape to build up the band to equal the insulation diameter. Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease to fill the step at the semi-con cut-off.
- Install Termination Body and Remove Core
For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully begin to remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted up to the leading edge of the mastic seal. Do not push or pull on the termination assembly while removing the core material.
- Lubricate Skirt, Fold Down, and Complete Seal
Apply a thin film of silicone lubricant to the skirt and mastic seal area (do not lubricate skirt tabs). Carefully fold down the skirt over the mastic seal. With the termination installed, complete the lug area moisture seal using the remaining gray silicone rubber tape. Overlap the termination insulator by approximately 1 inch and extend the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration.
- Connect Neutral Wires and Confirm High-K Step
Twist the concentric neutral wires together and connect them to the system ground. Confirm that the High-K step does not exceed 1.5 inches.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.