- 15KV outdoor termination for cable insulation diameters 0.64–1.12 inches
- Compatible with tape shield, wire shield, and UniShield cable types
- Aluminum barrel for aluminum conductors with copper wire lead options (#2–4/0, 4/0 compact/solid 250)
- Plated mild steel mounting bracket (1.10–1.50 inch / 28–38mm diameter range)
- Part of ABB Ranger2 line for reliable medium-voltage cable termination
Specifications
Application | Cable Termination, Outdoor Application, 15kV |
Cable Type | Copper Tape Shielded Wire |
Color | Gray |
Conductor Size | 4/0 AWG , 250 kcmil |
Earthing | Products Includes Their Own Grounding System |
Mounting | Product Need to have Cable Holder (not included) |
Number Of Terminals | (1) Single Phase |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Outdoor - Ranger2 |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

PCT10270-3
15kV, Single Piece Terminator (Class 1), Two Hole Spade Lug. Power Cable Termination, Conductor Size - 4/0 Stranded/Compressed, Use for Insulation Diameter Range from .640 to 1.070 inches.
R2T15M1-T0230
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.64 - 1.12 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #1/ Compact or Solid 1/0.
R2T15M1-T0240
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.64 - 1.12 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 1/0/ Compact or Solid 2/0.
R2T15M1-N0240
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.64 - 1.12 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1/0/ Compact or Solid 2/0.
R2T15M1-N0330
Outdoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 500 Stranded/Compressed or 600 Compact/Solid
R2T15M1-T1230-B1
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.64 - 1.12 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. includes Aluminum Barrel For Aluminum Conductor only with copper wire lead #2-4/0, Stranded or Compressed #1 /Compact or Solid 1/0. Stainless Steel Mounting Bracket .80 inch - 1.25 inch (20-32mm)
R2T15M1-N0230
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 230 -Stranded or Compressed #1 Compact or Solid 1/0.
R2T15M1-N0270
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.64 - 1.12 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 4/0/ Compact or Solid 250.Frequently Asked Questions
What is the maximum design voltage to ground?
The maximum design voltage to ground for the R2T15 termination is 9.5 kV.
What are the installation instructions for the R2T15?
Installation instructions are IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.
What is the power system frequency range?
The R2T15 termination is designed for a power system frequency range of 48 to 62 Hz.
What is the creepage distance for the R2T15?
The creepage distance for the R2T15 termination is 15.0 inches (381 mm).
What is the minimum strike distance for the R2T15?
The minimum strike distance for the R2T15 termination is 11.4 inches (381 mm).
What is the maximum altitude for installation?
The maximum altitude for installing the R2T15 termination is 3300 feet (1005 m).
What is the maximum ambient temperature for operation?
The R2T15 termination can operate in an ambient temperature range from -22 °F to +149 °F (-30 °C to +65 °C).
What is the voltage rating of the R2T15 termination?
The R2T15 termination has a voltage rating of 15 kV.
What cable sizes does the R2T15 termination support?
The R2T15 termination supports insulation diameters from 0.64 inches to 2.10 inches, covering #2 AWG through 1250 kcmil cables.
What is the maximum design voltage to ground?
The maximum design voltage to ground for the R2T15 termination is 9.5 kV.
How to Install the Ranger 2 Shrink-Fit Silicone Rubber Termination on Tape Shielded Cables
This guide provides detailed instructions for installing the 15kV & 28kV Ranger 2 Shrink-Fit Silicone Rubber Termination on tape shielded cables, covering cable preparation, ground braid attachment, lug installation, and final termination sealing.
Estimated time: 1h 30m
Tools needed:
Crimping tool, Wire strippers, Measuring tape, Utility knife or scissors, Aluminum oxide abrasive (120 grit or finer, optional)
Supplies needed:
Ranger 2 Shrink-Fit Silicone Rubber Termination Kit (includes termination, lubricant, silicone rubber tape, constant force spring, ground braid, sealing mastic, copper foil tape, gloves), Terminal lug or connector, Approved solvent, Vinyl electrical tape
- Prepare for Installation and De-energize Apparatus
DANGER: Ensure all apparatus is de-energized before beginning installation. This product must be installed by competent personnel trained in high voltage safety practices. Inspect the termination kit contents for completeness and damage. Verify the cable size fits the termination's insulation range. Train the cable into its final position and cut it to the required length, allowing for terminal lug depth and aluminum lug growth allowance.
- Prepare Cable Dimensions and Install Ground Braid
Prepare the cable according to the dimensions specified in the 'Jacket Removal Length' table, allowing for terminal lug depth and any aluminum lug growth allowance. Secure the tape shield's edge with a single wrap of the supplied copper foil tape to prevent unrolling. Wrap one band of mastic 1/4 inch (6mm) from the jacket end, ensuring it's flush. Position the preformed ground braid with the short tail over the tape shield and the solder block centered over the mastic, then secure it to the cable jacket with vinyl tape. Apply a second mastic band over the solder block, then wrap two half-lapped layers of vinyl tape over the mastic seal. Wrap the ground braid around the cable tape shield once, trim excess, and secure it with the constant force spring, cinching it tightly and securing with two wraps of vinyl tape.
- Install Terminal Lug and Clean Cable Insulation
Check that the termination assembly fits over your selected lug. If not, slide the termination onto the cable before installing the lug. Position the connector or lug and crimp it according to the manufacturer's directions, leaving the last 3/8 to 1/2 inch uncrimped. Remove any excess oxide inhibitor and all sharp crimp flashings or edges. Wipe the cable insulation with an approved solvent, being careful not to touch the semi-conductive insulation shield. If necessary, use aluminum oxide abrasive (120 grit or finer) on the insulation only, ensuring not to reduce the cable insulation diameter.
- Install Termination Body and Complete Moisture Seal
Create a track-resistant moisture seal by wrapping a band of gray silicone rubber electrical tape around the base of the terminal lug. If the barrel diameter is smaller than the cable primary insulation, build up the tape band to equal the insulation diameter. Cover the edge of the semi-conductive insulation shield with a liberal coating of silicone lubricant (grease) to fill the step. Pull the loose end of the removable core through the top of the termination until it is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, ensuring the termination body remains butted against the mastic seal. Apply a thin film of silicone lubricant to the skirt and mastic seal area (avoiding skirt tabs), then carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal with the remaining gray silicone rubber electrical tape, overlapping the termination insulator by approximately 1 inch and extending over a non-crimped region of the lug/connector barrel with a half-lap configuration. Finally, connect the ground braid to the system ground and confirm that the High-K step does not exceed 1.5 inches.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.