ABB - Installation Products K675LR-L-2380 - 900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

ABB Installation Products K675LR-L-2380 900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable…

UPC: 783786804467


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K675LR-L-2380 is a 900 Amp, 15/25kV 600 Series Elbow designed for medium-voltage cable terminations in industrial and utility applications. This deadbreak elbow connector includes an insulated plug, cap, stud, lug, and cable adapter, providing a complete termination solution for cable insulation diameters ranging from 1.180 inch to 1.465 inch. The copper compression lug is rated for compressed stranded 700/750 kcmil or compacted solid 900 kcmil conductors, ensuring reliable electrical contact and mechanical strength. Meets ANSI/IEEE Standard 386 for 15kV and 25kV voltage classes, with a continuous current rating of 900 Amps and a momentary rating of 25kA symmetrical for 10 cycles. The fully shielded, submersible molded rubber housing is constructed from 100% peroxide-cured EPDM materials, delivering long-term durability and environmental resistance. The elbow is designed for fully dead-front connections, enabling safe operation in confined spaces such as switchgear, transformers, and motor control centers. Compatible with a wide range of Elastimold® accessories, including the K675CP, K675BIP, K675RTP, K675RTW, and K675S1, the K675LR-L-2380 supports applications requiring visible external separation, bypass, isolation, dead-ending, grounding, and testing. Optional accessories also allow for the addition of taps, surge arrestors, and fault current indicators, enhancing system flexibility and functionality. The integrated components eliminate the need for separate accessories, reducing installation time and potential failure points while maintaining consistent performance in demanding environments.
  • 900 Amp continuous current rating for medium-voltage applications
  • Fully shielded, submersible molded rubber housing for environmental durability
  • Compatible with cable insulation diameters from 1.180 to 1.465 inch
  • Copper compression lug rated for 700/750 kcmil stranded or 900 kcmil solid conductors
  • Meets ANSI/IEEE Standard 386 for 15kV and 25kV voltage classes

Specifications

Amperage Rating
900 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
700 to 750 kcmil , 900 kcmil
Connection
Compression
Connection Type
Compression Lug
Current Rating
900 A
Environmental Conditions
All Weather Conditions, Fully Submersible
Insulation
True
Material
Copper, Insulated
Material
Housing - EPDM-Rubber
Series
600 Series
Size
1.180-1.465 inch (cable insulation diameter)
Size
Cable Insulation Diameter 1.180 inch to 1.465 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15 to 25 kV
Voltage Rating
15/25kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil.

656ETP-M0380-DRG

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil.
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70.

K675LR-J2250

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70.
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K675LR-M-2380

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K675LR-M2330

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp, 25kV, Deadbreak Elbow, Window Op Connector Kit with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. Cold-Shrinkable Jacket Seal Included. With Sheild Adapter.

K656ETP-H5260-S-TL

600 Amp, 25kV, Deadbreak Elbow, Window Op Connector Kit with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. Cold-Shrinkable Jacket Seal Included. With Sheild Adapter.
600 Amp, 15/25kV, 2-Way L-Kit, with Test Point. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K656L2-L0330

600 Amp, 15/25kV, 2-Way L-Kit, with Test Point. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp, 15/25kV, 4-Way L-Kit, with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.

K656L4-H5270-S

600 Amp, 15/25kV, 4-Way L-Kit, with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.
600 Amp, 25kV, Deadbreak Elbow, Window Op Connector Kit with Test Point. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K656ETP-M0380

600 Amp, 25kV, Deadbreak Elbow, Window Op Connector Kit with Test Point. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

Frequently Asked Questions

What is the maximum operating voltage for the K675LR?

The K675LR can be used through 28kV. For the 28kV class, the maximum phase-to-phase operating voltage is 28kV.

What is the continuous current rating for the K675LR?

The K675LR has a continuous current rating of 900 Amps for both 15kV and 28kV voltage classes.

What is the acceptable cable insulation diameter range?

The K675LR accommodates cable insulation diameters ranging from 0.640 inches to 1.935 inches.

What conductor sizes are compatible with K675LR?

The K675LR is compatible with conductor sizes from #2 AWG to 1250 kcmil for both aluminum and copper conductors.

What is the K675LR product used for?

The K675LR provides fully shielded, dead-front submersible cable connections to high-voltage apparatus. It is designed for use through 28kV.

What is the impulse withstand (BIL) rating?

The impulse withstand (BIL) rating is 95kV for the 15kV voltage class and 140kV for the 28kV voltage class.

What is the one-minute AC withstand voltage?

The one-minute AC withstand voltage is 34kV AC for the 15kV class and 45kV AC for the 28kV class.

What is the momentary current rating?

The momentary current rating is 25kA Symmetrical for 10 cycles for both 15kV and 28kV voltage classes.

What other Elastimold products are compatible with K675LR?

The K675LR can be mated with Elastimold products including K675CP, K675BIP, K675RTP, K675RTW, K675S1, K650J2, K650J3, and K650J4.

What items are included in a K675LR kit?

Each kit contains an elbow connector housing, a copper compression lug, a copper stud, an insulated plug with cap, lubricant tubes, a cable adapter, and installation instructions.

How to Install K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for installing 655/675LR and K655/K675LR deadbreak elbow connectors. These connectors create fully shielded, submersible deadfront cable connections for high voltage apparatus rated for 15kV and 25kV class systems.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Wire brush, Hotstick, Capacitive voltage sensing device, Torque wrench (for mating parts), Screwdriver

Supplies needed:

Lubricant (supplied with kit), No. 14 AWG Copper equivalent grounding wire, Suitable grounding connector, Silicone lubricant (for test point cap), Waterproofing material (for cable jacket)

  1. Ensure Safety and Inspect Components

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Verify that all components are complete, undamaged, and compatible with the cable and mating products. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.

  2. Prepare the Cable

    Position the cable with enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24 inches (610mm). Remove the outer jacket (if applicable) and prepare the cable insulation and semi-con shield to the dimensions specified in the documentation for your cable type.

  3. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare Conductor and Crimp Lug

    Remove any protruding cable insulation by cutting it even with the end of the cable adapter, taking care not to nick the adapter or conductor. The exposed conductor length must be between 4-1/4 inches and 4-9/16 inches (108mm-116mm). For aluminum conductors, wire brush the conductor immediately before insertion. Fully insert the conductor into the compression lug. Measure the 'Check Dimension' before crimping (must be less than 6-3/8 inches). Crimp the compression lug according to its supplied instructions. Wipe off any excess inhibitor and verify the post-crimp distance from the lug end to the cable adapter is 6-3/8 to 7-1/8 inches (162mm-181mm).

  5. Install the Elbow

    Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  6. Connect to Mating Products

    DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from the elbow and the mating part. If the mating part lacks a stud, hand tighten the threaded stud supplied with the elbow into it. Clean and lubricate both the elbow and the mating part with the supplied lubricant. Push the elbow onto the mating part, aligning the compression lug hole with the stud. If connecting a second mating part, clean, lubricate, insert, and torque it according to its instructions. If using an insulating plug, clean, lubricate, and push the voltage detection cap onto the elbow until it snaps into place.

  7. Ground the Cable Shield

    Insert one end of a No. 14 AWG Copper equivalent grounding wire through the grounding eye, twist to form a small loop, and connect it to ground using a suitable connector. Ensure the cable shield is grounded according to the instructions for your grounding device or an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  8. Perform Voltage Test

    Remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable capacitive sensing device, following its manufacturer's directions, to determine if the cable is energized. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means to prevent serious injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.