Authorized ABB Distributor (Installation Products)
ABB - Installation Products K675LR-J2250 - 900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70.

ABB Installation Products K675LR-J2250 900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable…

UPC: 783786583638


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K675LR-J2250 is a 900 Amp, 15/25kV 600 Series Elbow Kit engineered for reliable, fully shielded, dead-front submersible cable connections in high-voltage electrical infrastructure. This comprehensive kit includes an elbow connector housing, insulated plug with cap, copper compression lug, copper stud, and cable adapter, providing all necessary components for secure medium-voltage terminations. Designed to meet ANSI/IEEE Standard 386, the K675LR-J2250 supports conductor sizes from 2/0 AWG to 1250 kcmil (aluminum/copper) with insulation diameters ranging from 0.640" to 1.935". The fully molded rubber housing is 100% peroxide-cured EPDM, ensuring durability and resistance to environmental stress. With a continuous current rating of 900 Amps and momentary withstand of 25kA for 10 cycles, this elbow connector is rated for 15kV (8.3kV phase-to-ground, 14.4kV phase-to-phase) and 25kV (16.2kV phase-to-ground, 28kV phase-to-phase) applications. The deadbreak design allows safe connection/disconnection in de-energized states using standard hand tools. Optional accessories enable visible separation, bypass, isolation, grounding, testing, and integration of taps, surge arrestors, or fault current indicators. Compatible with Elastimold® products including K675CP, K675BIP, K675RTP, K675RTW, K675S1, and K650J2-J4 series. Ideal for submersible cable connections to transformers, switchgear, and other high-voltage apparatus in utility, industrial, and commercial power distribution systems.
  • 900 Amp continuous current rating with 25kA momentary withstand (10 cycles)
  • Supports 15kV/25kV voltage classes; meets ANSI/IEEE Standard 386
  • Fully shielded, dead-front, submersible molded rubber housing (EPDM)
  • Accommodates conductor sizes: 2/0 AWG to 1250 kcmil (stranded/compressed) and 70 mm² compacted
  • Includes copper compression lug, insulated plug with cap, stud, and cable adapter

Specifications

Amperage Rating
900 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Connection
Compression
Connection Type
Compression Lug, Crimp Connector
Connection Type
Compression
Current Rating
900 A
Environmental Conditions
All Weather Conditions, Fully Submersible
Insulation
True
Material
Copper, Poly
Material
Housing - EPDM-Rubber
Material
Copper
Series
600 Series
Size
Cable Insulation Diameter 0.980 inch to 1.180 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug. 2/0 Stranded or Compressed, 3/0 Solid or Compact Wire Size. Includes Straight Receptacle Housing, Receptacle Pin Connector, Lubricant, Installation instructions and Crimp Chart

K151SR-A2250

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug. 2/0 Stranded or Compressed, 3/0 Solid or Compact Wire Size. Includes Straight Receptacle Housing, Receptacle Pin Connector, Lubricant, Installation instructions and Crimp Chart
Copper-coated conductor 1,90m 63A x2

173G0412

Copper-coated conductor 1,90m 63A x2
Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC

V-25TB

Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K675LR-M-2380

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K675LR-M2330

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp, 25kV, Deadbreak Elbow, Window Op Connector Kit with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. Cold-Shrinkable Jacket Seal Included. With Sheild Adapter.

K656ETP-H5260-S-TL

600 Amp, 25kV, Deadbreak Elbow, Window Op Connector Kit with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. Cold-Shrinkable Jacket Seal Included. With Sheild Adapter.
600 Amp, 15/25kV, 2-Way L-Kit, with Test Point. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K656L2-L0330

600 Amp, 15/25kV, 2-Way L-Kit, with Test Point. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp, 15/25kV, 4-Way L-Kit, with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.

K656L4-H5270-S

600 Amp, 15/25kV, 4-Way L-Kit, with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.

Frequently Asked Questions

What is included in a K675LR kit?

Each kit contains an elbow connector housing, copper compression lug, copper stud, insulated plug with cap, lubricant, cable adapter, and installation instructions.

What accessories are compatible with the K675LR?

The K675LR can be mated with other Elastimold® Products including K675CP, K675BIP, K675RTP, K675RTW, K675S1, K650J2, K650J3, and K650J4.

Is the K675LR elbow submersible?

Yes, the K675LR features a fully shielded, fully submersible molded rubber housing.

What ANSI/IEEE standard does the K675LR meet?

The K675LR meets ANSI/IEEE Standard 386, Latest Revision.

What is the continuous current rating for the K675LR?

The K675LR has a continuous current rating of 900 Amps for both 15kV and 28kV voltage classes.

What insulation diameters does the K675LR support?

The K675LR supports insulation diameters from .640 inches to 1.935 inches.

What conductor sizes are compatible with the K675LR?

It is compatible with aluminum and copper conductors ranging from #2 AWG to 1250 kcmil.

What is the maximum voltage for the K675LR elbow?

The K675LR elbow connector can be used through 28kV.

What accessories are compatible with the K675LR?

The K675LR can be mated with other Elastimold® Products including K675CP, K675BIP, K675RTP, K675RTW, K675S1, K650J2, K650J3, and K650J4.

What conductor sizes are compatible with the K675LR?

It is compatible with aluminum and copper conductors ranging from #2 AWG to 1250 kcmil.

How to Install K655/K675LR and 655/675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of Elastimold 600-ampere and 900-ampere deadbreak elbow connectors on 15kV and 25kV class systems. It covers cable preparation, connector assembly, and grounding.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Utility knife, Crimping tool, Wire brush, Hotstick, Suitable sensing device (for capacitive test points), Torque wrench, Measuring tape

Supplies needed:

Lubricant (supplied with elbow), Threaded stud (supplied with elbow, if needed), No. 14 AWG Copper wire (or equivalent ampacity), Suitable connector (for grounding wire), Silicone lubricant, Tape marker

  1. Prepare for Installation and Ensure Safety

    DANGER: Ensure all apparatus are de-energized before starting installation or removal of any parts. Do not touch or move energized products. Inspect all package contents and components for completeness, damage, proper rating, and compatibility with mating parts. Have all required tools ready and maintain cleanliness throughout the procedure.

  2. Prepare the Cable

    Assemble the cable in its final position, ensuring enough slack for elbow removal. For concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24” (610mm) or up to the bent back concentric neutral wires. Remove the outer jacket (if applicable) and prepare the cable insulation, semi-con shield, and shield wires/tape to the specified dimensions (9-3/4”, 10-3/4”, 12-3/4” tape markers).

  3. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare the Conductor and Crimp Lug

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. Verify the length of the exposed conductor is between 4-1/4” and 4-9/16” (108mm-116mm). For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping (must be less than 6-3/8”). Crimp the compression lug according to the supplied instructions. Wipe all excess inhibitor from the lug and cable adapter. After crimping, verify the distance from the end of the lug to the cable adapter is between 6-3/8” to 7-1/8” (162mm-181mm).

  5. Install the Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  6. Connect to Mating Products

    WARNING: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from both the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud (supplied with the elbow) into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean. Push the elbow onto the mating part, aligning the hole in the compression lug with the stud on the mating part.

  7. Connect the Opposite End and Torque

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part. CAUTION: For 600amp L-Kits, ensure each component is tightened to its specified torque.

  8. Install Insulating Plug (If Applicable)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down hard until it snaps into place.

  9. Ground the Cable Shield

    Insert one end of a wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; follow instructions supplied with the grounding device or use an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  10. Perform Voltage Test (Optional)

    If performing a voltage test, remove the test point cap with a hotstick by peeling it off at an angle, rather than pulling directly. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points and follow its manufacturer’s directions. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means, as contamination or incorrect equipment can give false readings. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.