Authorized ABB Distributor (Installation Products)
ABB - Installation Products K675LR-M-2380 - 900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

ABB Installation Products K675LR-M-2380 900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable…

UPC: 783786665860


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB K675LR-M-2380 is a 900 Amp, 15/25kV, 600 Series Elbow connector for medium-voltage cable systems. Includes insulated plug, cap, stud, lug, and cable adapter for 1.370"–1.630" cable insulation diameters. Copper compression lug rated for compressed stranded 700/750 kcmil or compacted solid 900 kcmil conductors. Part of ABB’s 600 Series, compatible with industry-standard switchgear and transformers. Integrated plug and cap design simplifies installation/removal. Cable adapter accommodates varying insulation diameters. Used in utility substations, industrial plants, and commercial facilities for medium-voltage distribution. Compression lug ensures low-resistance contact, reducing heat generation and improving efficiency. Installation requires standard tools and follows ABB’s documented procedures for 600 Series elbows. Order using SKU K675LR-M-2380. Verify conductor size and cable insulation diameter before installation.
  • 900 Amp, 15/25kV rating for medium-voltage systems
  • Includes insulated plug, cap, stud, lug, and cable adapter
  • Supports cable insulation diameter: 1.370 inch to 1.630 inch
  • Copper compression lug for 700/750 kcmil stranded or 900 kcmil solid conductors
  • Part of ABB’s 600 Series, compatible with standard switchgear and transformers

Specifications

Amperage Rating
900 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
700 to 750 kcmil , 900 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions, Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15 to 25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.0010 L
Package Weight (Metric)
0.0010 kg
900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included. Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

776LR-P2380-SG3

900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included. Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K675LR-M2330

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp, 25kV, Deadbreak Elbow, Window Op Connector Kit with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. Cold-Shrinkable Jacket Seal Included. With Sheild Adapter.

K656ETP-H5260-S-TL

600 Amp, 25kV, Deadbreak Elbow, Window Op Connector Kit with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. Cold-Shrinkable Jacket Seal Included. With Sheild Adapter.
600 Amp, 15/25kV, 2-Way L-Kit, with Test Point. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K656L2-L0330

600 Amp, 15/25kV, 2-Way L-Kit, with Test Point. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp, 15/25kV, 4-Way L-Kit, with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.

K656L4-H5270-S

600 Amp, 15/25kV, 4-Way L-Kit, with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.
600 Amp, 25kV, Deadbreak Elbow, Window Op Connector Kit with Test Point. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K656ETP-M0380

600 Amp, 25kV, Deadbreak Elbow, Window Op Connector Kit with Test Point. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
600 Amp, 35kV, 600 Series Deadbreak 3-Way L-Kit. 200ECS-G3 Jacket Seal and Grounding Kit Included.

755L3-K5270-SG3

600 Amp, 35kV, 600 Series Deadbreak 3-Way L-Kit. 200ECS-G3 Jacket Seal and Grounding Kit Included.
15/25kV 600 Series Deadbreak 2-Way L-Kit, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K655L2-L0330

15/25kV 600 Series Deadbreak 2-Way L-Kit, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

Frequently Asked Questions

What items are included in a K675LR kit?

Each kit includes the elbow connector housing, copper compression lug, copper stud, insulated plug with cap, lubricant, cable adapter, and installation instructions.

What is the primary application of the K675LR elbow connector?

The K675LR provides fully shielded, dead-front submersible cable connections to high-voltage apparatus.

What conductor and insulation diameter ranges does K675LR support?

It supports #2 AWG to 1250 kcmil aluminum/copper conductors, with insulation diameters from 0.640 in to 1.935 in.

What other Elastimold products are compatible with K675LR?

The K675LR can be mated with K675CP, K675BIP, K675RTP, K675RTW, K675S1, K650J2, K650J3, and K650J4.

What industry standard does the K675LR meet?

The K675LR meets ANSI/IEEE Standard 386, Latest Revision.

What are the 15kV class operating voltage ratings?

For 15kV class, max phase-to-ground operating voltage is 8.3kV and max phase-to-phase is 14.4kV.

What are the 28kV class operating voltage ratings?

For 28kV class, max phase-to-ground operating voltage is 16.2kV and max phase-to-phase is 28kV.

What is the continuous current rating for the K675LR?

The continuous current rating for both 15kV and 28kV voltage classes is 900 Amp.

How is the K675LR connected or disconnected?

It connects/disconnects using standard hand tools and equipment, but only when in a de-energized state.

What items are included in a K675LR kit?

Each kit includes the elbow connector housing, copper compression lug, copper stud, insulated plug with cap, lubricant, cable adapter, and installation instructions.

How to Install Elastimold 655/675LR and K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of Elastimold 655/675LR and K655/K675LR Deadbreak Elbow Connectors, including cable preparation, lug crimping, connection to mating apparatus, and optional voltage testing.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Wire brush, Hotstick, Capacitive voltage sensing device, Grounding connector tool

Supplies needed:

Elastimold Deadbreak Elbow Connector (655/675LR or K655/K675LR), Cable Adapter, Compression Lug, Lubricant (silicone), Threaded Stud (if mating part not equipped), No. 14 AWG Copper grounding wire (or equivalent), Suitable grounding connector, Insulating Plug (optional), HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. De-energize and Prepare Work Area

    DANGER: Ensure all apparatus in the work area are de-energized before beginning installation or removal of any parts. Do not touch or move energized products in the work area. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Verify the cable is in its final assembled position with sufficient slack to allow for elbow removal. For concentric neutral cable, unwind the concentric neutral wires.

  2. Prepare the Cable End

    Cut the cable 1-3/4 inches (45mm) from the center line of the mating product. Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent back concentric neutral wires. Remove the outer jacket (if applicable) and prepare the cable insulation and semi-con shield according to the specific cable type, ensuring the correct lengths (e.g., 9-3/4”, 10-3/4”, 12-3/4” as indicated in the documentation diagrams).

  3. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean the cable insulation, then lubricate it, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare Conductor and Crimp Lug

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Verify the exposed conductor length is between 4-1/4 inches and 4-9/16 inches (108mm-116mm). For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it. Measure the 'Check Dimension' before crimping to ensure it is less than 6-3/8 inches. Crimp the compression lug according to its supplied instructions. Wipe off all excess inhibitor from the lug and cable adapter surface. After crimping, confirm the distance from the end of the compression lug to the cable adapter is between 6-3/8 inches to 7-1/8 inches (162mm-181mm).

  5. Install the Elbow Connector

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter, pushing until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  6. Connect to Mating Apparatus

    DANGER: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove any protective caps from the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud (supplied with the elbow) into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant. Push the elbow onto the mating part, carefully aligning the hole in the compression lug with the stud on the mating part. For the opposite end of the elbow, clean and lubricate the mating part, then insert it into the elbow. Engage the threads and hand tighten, then torque the mating part according to its specific instructions. If using an insulating plug, clean and lubricate the inner surface of the voltage detection cap and push it onto the elbow until it snaps into place.

  7. Ground the Cable Shield

    Insert one end of a wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow instructions supplied with any grounding device or use an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  8. Perform Voltage Test (Optional)

    WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. If performing a voltage test, remove the test point cap from the elbow's integral capacitance test point using a hotstick, peeling it off at an angle. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized, following the meter manufacturer's directions. Contamination, moisture, dirt, etc., or using the wrong measuring equipment can provide a false 'no voltage' indication. To prevent serious or fatal injury, treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means. After the voltage detection is made, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.