- 900 Ampere current rating for high-power applications
- Four connection points for versatile wiring configurations
- Constructed with copper conductors for efficient current transfer
- Features a rubber junction seal for environmental protection
- Includes stainless steel mounting plate, back plate, and adjustable bracket for secure and flexible installation
Specifications
Application | 900 Amps |
Current Rating | 900 A |
Material | Copper |
Mounting Type | Adjustable Mounting Bracket |
Poles | 4 |
Series | K675 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Junction 4-Point |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 29.0000 L |
Package Weight (Metric) | 13.1540 kg |

K655ALR-H0270
600 Amp, DeadBreak, 15/25KV, Access Elbow, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
K655ALR-HO270
600 Amp, DeadBreak, 15/25KV, Access Elbow, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
K655YBSRN
600 Amp, Straight Receptacle Housing Only, 15/25 KV, DeadBreak, Without the Bolt and Washers
K650ECP
600 Amp, Extended Connector Plug, DeadBreak, 15/25KV. Widest Diameter 3 inches. Center Body Length 5.5 inch.
K655VSL2-DP0592392
600 Amp, 2 Way Vault Stretcher Kit, 15/25KV, G0260 - Cable Insulation Diameter 0.760 inch to 0.950 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 3/0 or Compacted/Solid 4/0. J0270 - Cable Insulation Diameter 0.980 inch to 1.180 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 4/0 or Compacted/Solid 250. SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring. (K655VS-L2-G0260-J0270-SG3).
K655BLR-N0400
600 Series Elbow with out Test Point, With Stud, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 900 /Solid 1000 /mmSquared 500.Frequently Asked Questions
What are the applications for the K675J4 junction?
It is designed for subsurface, vault, or padmount applications. It can be used for sectionalizing, looping, tapping, and equipment bypass.
What is the K675J4 product?
The K675J4 is a 15/25kV, 900 Amp Deadbreak 4-Way Junction.
What products are compatible with the K675J4 junction?
It mates with Elastimold 900 A Series Elbow connectors, K675 Elbow Connector, K675BE Bushing Extender, and 675BEA3 Bushing Adapter.
What is the 15kV class operating voltage?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and maximum phase-to-phase is 14.4kV.
What is the 28kV class operating voltage?
For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV and maximum phase-to-phase is 28kV.
What is the continuous current rating?
The continuous current rating for both 15kV and 28kV voltage classes is 900 Amp.
What is the momentary current rating?
The momentary current rating for both 15kV and 28kV voltage classes is 25kA Sym for 10 Cycles.
What items are included in the K675J4 kit?
The kit contains one basic molded junction, mounting hardware, two tubes of lubricant, installation instructions, and four protective caps.
What standard does the K675J4 junction meet?
The K675J4 junction meets ANSI/IEEE Standard 386, Latest Revision.
What standard does the K675J4 junction meet?
The K675J4 junction meets ANSI/IEEE Standard 386, Latest Revision.
How to Install the K675-J4-U Deadbreak Junction (Universal Mount)
This guide provides step-by-step instructions for the universal mounting and initial setup of the K675-J4-U Two-, Three-, or Four-Point Deadbreak Junction. Ensure all apparatus are de-energized before beginning installation to prevent serious injury or death.
Estimated time: 1h
Tools needed:
Wrench set, Socket set, Wire strippers, Measuring tape, Marking tool
Supplies needed:
K675-J4-U Deadbreak Junction, Base Bracket, Base Plate, Universal Brackets (4), Mounting Hardware Prepack (includes various screws, washers, nuts), Suitable fasteners (user supplied, for mounting brackets to surface), Grounding wire (No. 2 solid to 1/0 stranded), ELASTIMOLD approved lubricant, Insulated caps (for unused bushings)
- De-energize and Prepare Work Area
DANGER: Before beginning, ensure all apparatus are completely de-energized. This product should only be installed by competent personnel trained in high-voltage electrical equipment safety practices. Determine the desired location for the junction assembly on a flat surface.
- Mark Mounting Locations
Using the base plate as a template, place it on the chosen surface and accurately mark all slot locations for mounting.
- Mount Initial Universal Brackets
Attach two (2) universal brackets to the marked flat surface using suitable fasteners (supplied by user). Tighten them securely to prevent any movement during operation.
- Attach Remaining Universal Brackets
Connect the remaining two (2) universal brackets to the previously mounted brackets at the desired angle using the supplied 3/8” hex head cap screws, external tooth lock washers, and 3/8” hex nuts. Tighten securely.
- Assemble Junction to Base
Assemble the deadbreak junction to the base bracket assembly and base plate. Use two (2) 1/2” hex head cap screws, two (2) 1/2” split lock washers, and two (2) 1/2” hex nuts, attaching them to the center mounting holes on the bracket assembly. Tighten all hardware securely.
- Mount Junction Assembly to Brackets
Attach the fully assembled deadbreak junction to the universal brackets using the supplied 1/2” hex head cap screws, 1/2” split lock washers, and 1/2” hex nuts. Ensure the parking stand is in an upright position and tighten all connections securely.
- Ground the Assembly
Connect a grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket. Ensure the base bracket assembly and the junction’s black conductive jacket are properly grounded to a suitable ground point.
- Prepare Operating Interfaces
Remove all protective shipping caps from the operating interfaces. Clean each interface thoroughly and lubricate it with an ELASTIMOLD approved lubricant. DO NOT SUBSTITUTE, as other lubricants may be harmful to this product or its mating product(s).
- Install Insulated Caps (if needed)
If any operating interfaces are not utilized, install appropriate insulated caps on the unused bushing(s) before energizing the circuit. Do NOT use the protective shipping caps for this purpose, as they are not insulated and are only for shipping protection.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.