ABB - Installation Products K675BLR - 15/25kV, 900 Amp Deadbreak, Elbow Housing without Test Point, with Stud.

ABB Installation Products K675BLR 15/25kV, 900 Amp Deadbreak, Elbow Housing without Test Point, with Stud.

UPC: 783786644018


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 600 Series 15/25kV 900 Amp Deadbreak Elbow Housing with Stud (SKU K675BLR) is a medium-voltage deadbreak connector designed for high-current terminations in distribution networks, substations, and industrial power systems. Rated for 15/25 kV systems, this elbow housing supports continuous current ratings up to 900 Amps, making it ideal for high-load applications where reliable, load-break operations are required without service interruption. The deadbreak design ensures safe disconnection under load, while the integrated stud simplifies installation and termination with standard 600A deadbreak bushings and connectors. This housing is compatible with existing infrastructure, eliminating the need for test points in applications where external or alternative testing methods are used. Typical applications include utility power distribution, renewable energy interconnections, and commercial/industrial switchgear operating within 15/25 kV class systems. The product is part of ABB’s 600 Series, ensuring interoperability and standardized performance in medium-voltage deadbreak connector applications.
  • Rated for 15/25 kV systems with 900 Amp continuous current capacity
  • Deadbreak design enables safe load-break operations without service interruption
  • Integrated stud simplifies installation and termination with standard 600A deadbreak bushings
  • Compatible with existing ABB 600 Series infrastructure for interoperability
  • No test point included; designed for external or alternative testing methods

Specifications

Application
15/25 kV, 900 Amps
Material
Copper
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Elbow without Test Point
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
4.1000 L
Package Weight (Metric)
1.8600 kg
900 Amp, 35kV, 600 Series Elbow with Test Point Housing only, with Stud.

776BLR

900 Amp, 35kV, 600 Series Elbow with Test Point Housing only, with Stud.
15/25kV 600 Series Deadbreak Reducing Tap Well wih factory assembled stud which is not field removable.

K650RTWSP

15/25kV 600 Series Deadbreak Reducing Tap Well wih factory assembled stud which is not field removable.
15/25kV 600 Series Deadbreak Elbow without Test Point Housing Only (with Stud), Basic Insulating Plug.

K655BLR-BIP

15/25kV 600 Series Deadbreak Elbow without Test Point Housing Only (with Stud), Basic Insulating Plug.
15/25kV, 900Amp, Deadbreak, Bushing Extender with Stud.

K675BE

15/25kV, 900Amp, Deadbreak, Bushing Extender with Stud.
15/25kV 600 Series Deadbreak Reducing Tap Plug, with Stud. 600/200 Amps.

K650RTPS

15/25kV 600 Series Deadbreak Reducing Tap Plug, with Stud. 600/200 Amps.
600 Amp, 15/25kV, Deadbreak, Connecting Plug. Widest Diameter 3 inches. With Loose Stud.

K650CPS

600 Amp, 15/25kV, Deadbreak, Connecting Plug. Widest Diameter 3 inches. With Loose Stud.
15/25kV 600 Series Deadbreak Elbow without Test Point (with Stud), Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.

K655BLR-H0280

15/25kV 600 Series Deadbreak Elbow without Test Point (with Stud), Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.
600 Amp, 15/25kV, Deadbreak, Connecting Plug. Widest Diameter 3 inches. With Factory assembled Stud which is not field removable.

K650CPSP

600 Amp, 15/25kV, Deadbreak, Connecting Plug. Widest Diameter 3 inches. With Factory assembled Stud which is not field removable.

Frequently Asked Questions

What is the K675BLR product?

The K675BLR is a 15/25kV 900A Deadbreak Elbow Housing without a test point, part of the Elastimold® 900 A elbow product line.

What standards does the K675BLR meet?

The K675BLR meets ANSI/IEEE Standard 386, Latest Revision.

What is the momentary current rating?

The momentary current rating is 25kA Symmetrical for 10 Cycles for both 15kV and 28kV voltage classes.

How do I order the K675BLR elbow housing?

To order the 15/25kV 900A elbow housing without a test point, specify K675BLR.

What items are included in the K675BLR kit?

Each kit contains one K675BLR elbow connector housing, one tube of lubricant 82-08, one copper stud 675SA, and installation instruction IS-0249.

Can accessories be used with the K675BLR?

Yes, optional accessories allow for visible external separation, by-pass, isolation, dead-ending, grounding, testing, and adding taps, surge arrestors, and fault current indicators.

What are the key features of the K675BLR housing?

It is a fully shielded, fully submersible molded rubber housing with 100% peroxide-cured construction. It is rated for 15/25kV, 900 Amp.

What is the impulse withstand rating for the K675BLR?

The impulse withstand (BIL) is 95kV for the 15kV class and 140kV for the 28kV class.

What are the 28kV operating voltage ratings?

For the 28kV class, the maximum phase-to-ground operating voltage is 16.2kV and the maximum phase-to-phase is 28kV.

What are the 15kV operating voltage ratings?

For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV and the maximum phase-to-phase is 14.4kV.

How to Install K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for installing 655/675LR and K655/K675LR deadbreak elbow connectors. These connectors create fully shielded, submersible deadfront cable connections for high voltage apparatus rated for 15kV and 25kV class systems.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Wire brush, Hotstick, Capacitive voltage sensing device, Torque wrench (for mating parts), Screwdriver

Supplies needed:

Lubricant (supplied with kit), No. 14 AWG Copper equivalent grounding wire, Suitable grounding connector, Silicone lubricant (for test point cap), Waterproofing material (for cable jacket)

  1. Ensure Safety and Inspect Components

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Verify that all components are complete, undamaged, and compatible with the cable and mating products. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.

  2. Prepare the Cable

    Position the cable with enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24 inches (610mm). Remove the outer jacket (if applicable) and prepare the cable insulation and semi-con shield to the dimensions specified in the documentation for your cable type.

  3. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare Conductor and Crimp Lug

    Remove any protruding cable insulation by cutting it even with the end of the cable adapter, taking care not to nick the adapter or conductor. The exposed conductor length must be between 4-1/4 inches and 4-9/16 inches (108mm-116mm). For aluminum conductors, wire brush the conductor immediately before insertion. Fully insert the conductor into the compression lug. Measure the 'Check Dimension' before crimping (must be less than 6-3/8 inches). Crimp the compression lug according to its supplied instructions. Wipe off any excess inhibitor and verify the post-crimp distance from the lug end to the cable adapter is 6-3/8 to 7-1/8 inches (162mm-181mm).

  5. Install the Elbow

    Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  6. Connect to Mating Products

    DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from the elbow and the mating part. If the mating part lacks a stud, hand tighten the threaded stud supplied with the elbow into it. Clean and lubricate both the elbow and the mating part with the supplied lubricant. Push the elbow onto the mating part, aligning the compression lug hole with the stud. If connecting a second mating part, clean, lubricate, insert, and torque it according to its instructions. If using an insulating plug, clean, lubricate, and push the voltage detection cap onto the elbow until it snaps into place.

  7. Ground the Cable Shield

    Insert one end of a No. 14 AWG Copper equivalent grounding wire through the grounding eye, twist to form a small loop, and connect it to ground using a suitable connector. Ensure the cable shield is grounded according to the instructions for your grounding device or an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  8. Perform Voltage Test

    Remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable capacitive sensing device, following its manufacturer's directions, to determine if the cable is energized. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means to prevent serious injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.