ABB Installation Products K650BIPS 15/25kV 600 Series Deadbreak Insulated Plug (with Cap), Loose Stud.
UPC: 783786637430
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25kV Voltage Rating for Medium Voltage Systems
- 600 Series Deadbreak Design for Safe Isolation
- Includes Insulated Plug with Cap and Loose Stud
- Manufactured by ABB Installation Products
- SKU: K650BIPS for easy identification
Specifications
Application | 15/25 kV, 600 Amps |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Insulated Plug with Cap |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.4300 L |
Package Weight (Metric) | 0.6490 kg |

K675TBC
15/25kV, 900 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Boot and Collar.
K650RTWSP
15/25kV 600 Series Deadbreak Reducing Tap Well wih factory assembled stud which is not field removable.
K655BLR-BIP
15/25kV 600 Series Deadbreak Elbow without Test Point Housing Only (with Stud), Basic Insulating Plug.Frequently Asked Questions
How do I order the K650BIP insulating plug?
To order the 15/25kV, 600A insulating plug, specify K650BIP.
What is the K650BIP product?
The K650BIP is a 15/25kV 600 Amp Deadbreak Insulating Plug with a test point.
What is the primary application of the K650BIP?
It attaches and insulates Elastimold® K655/6BLR, K655BE, and K655BVS 600 A connectors.
What standards does the K650BIP meet?
The K650BIP meets ANSI/IEEE Standard 386, Latest Revision.
What are the standard features of the K650BIP?
It is equipped with a capacitive test point and a molded rubber sealing cap as standard. The hex nut also serves as a capacitive test point.
What is the continuous current rating?
The continuous current rating for the K650BIP is 600 Amp.
What is the momentary current rating?
The momentary current rating is 25kA Symmetrical for 10 cycles.
What is the maximum 15kV phase-to-ground operating voltage?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.
What is the 15kV BIL impulse withstand rating?
The BIL impulse withstand rating for the 15kV voltage class is 95kV (1.2 x 50 microsecond wave).
What is the maximum 28kV phase-to-ground operating voltage?
For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV.
How to Install the K650BIPS (LINK-C) Deadbreak Cam Link Operable Connector System
This guide provides step-by-step instructions for the safe and proper installation of the 600 amp K650BIPS (LINK-C) Deadbreak Cam Link Operable Connector System. Ensure all apparatus are de-energized before beginning installation and follow all local and national work rules.
Estimated time: 2h
Tools needed:
Suitable tool for 1 inch hex (e.g., socket wrench), Torque wrench, Hot stick, 600ATM Operating Tool
Supplies needed:
ELASTIMOLD supplied lubricant, 3/8-16 x 2 inch long studs (if not pre-welded), Hex nuts, Lockwashers, Spacers (optional), No. 14 AWG or No. 12 AWG solid copper wire, Appropriate grounding connector
- Install the 600 Amp Elbow
Install the 600 amp elbow onto the cable according to the installation instructions supplied with the elbow. Ensure that the elbow will align correctly with the stand-off plug.
- Mount the Stand-Off Plug (If Applicable)
If using a mounted stand-off plug, weld three 3/8-16 x 2 inch studs to the faceplate following customer standard practice and specified dimensions. Install three hex nuts onto the studs to support the stand-off plug, ensuring it aligns with the bushing. Place the stand-off plug over the studs, resting on the nuts or optional spacers. Secure with three lockwashers and hex nuts, tightening each to 12 foot-lbs torque. Verify that the top surfaces of the apparatus bushing and stand-off plug are in-line.
- Install Bushing Extender and Elbow onto Stand-Off Plug
Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender with ELASTIMOLD supplied lubricant. Install the bushing extender onto the apparatus bushing. Insert the 600ATM into the retainer contact, engage the internal hex broach, and thread the retainer contact into the apparatus bushing using a suitable tool on the 1 inch hex portion of the 600ATM, torquing to 50-60 ft-lbs. Next, clean and lubricate the epoxy stand-off plug and both interfaces of the 600 amp elbow. Install the elbow onto the epoxy stand-off plug. Insert the 600AMT into the retainer contact, engage the internal hex broach, and thread the retainer contact into the epoxy stand-off plug through the hole in the compression lug using a suitable tool on the 1 inch hex portion of the 600AMT, torquing to 50-60 ft-lbs.
- Install the Alignment Bracket
Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush with each other and tight on both sides. Position the elbow in the alignment bracket such that the elbow cuff is lined up evenly with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush with each other and tight on both sides. Ensure the elbow clamp notch faces the cable entrance of the elbow.
- Insert and Engage the Link
Clean and thoroughly lubricate both 600 ampere interfaces of the Link with ELASTIMOLD supplied lubricant. Align the Link such that when inserted into the bushing extender and elbow, the Link is perpendicular to the switch faceplate. Insert the Link into the bushing extender and elbow, making sure both lever arms are on the inside of the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, move the lever arms downward by use of a hot stick eye, thus engaging the roller pin and moving the Link inward. Continue moving lever arms until they are perpendicular to the alignment bracket leg.
- Perform Grounding and Final Connections
Ground the elbow by feeding a #14 AWG or #12 AWG solid copper wire through the grounding eye on the elbow, twisting it tight, and connecting it to ground. Clean and lubricate the 200 amp interface on the Link. Ground, then install the desired mating product on the 200 amp interface per its specific installation instructions. Ground the cable: if concentric neutral cable is used, twist the concentric neutral wires together and connect to ground using an appropriate connector; if 20MA or 21MA grounding devices are used, connect the ground lead from the device to ground using a suitable connector. For three-phase installations, all grounds from all three phases must be tied to a common ground point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.