Authorized ABB Distributor (Installation Products)
ABB - Installation Products K675-J2-5 - 900 Amp, 2 point Junction, Copper, with rubber junction, stainless steel U-Straps and back plate

ABB Installation Products K675-J2-5 900 Amp, 2 point Junction, Copper, with rubber junction, stainless steel U-Straps and…

UPC: 783786642403


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K675-J2-5 is a 900 Amp, 15/25kV deadbreak 2-way junction designed for high-current electrical connections in subsurface, vault, or padmount applications. Constructed with a fully shielded, fully submersible molded rubber housing, it features 100% peroxide-cured EPDM insulation and conductive materials for reliable performance. This junction provides mating for Elastimold® 900 A Series Elbow connectors and is compatible with K675 Elbow Connectors, K675BE Bushing Extenders, and 675BEA3 Bushing Adapters. The unit includes a stainless steel mounting bracket and back plate for secure surface mounting. It meets ANSI/IEEE Standard 386. For the 15kV voltage class, it supports 8.3kV Max Phase-to-Ground operating voltage and 14.4kV Max Phase-to-Phase, with a 95kV BIL rating. For the 28kV voltage class, it supports 16.2kV Max Phase-to-Ground operating voltage and 28kV Max Phase-to-Phase, with a 140kV BIL rating. Both classes offer 900 Amp continuous current rating and 25kA Sym for 10 Cycles Momentary. The K675-J2-5 includes the basic molded junction, mounting hardware, lubricant, installation instructions, and protective caps.
  • 15/25kV, 900 Amp Deadbreak 2-Way Junction
  • Fully shielded, fully submersible molded rubber housing
  • 100% peroxide-cured EPDM insulation and conductive materials
  • Mates with Elastimold® 900 A Series Elbow connectors
  • Includes stainless steel mounting bracket and back plate

Specifications

Application
900 Amps
Current Rating
900 A
Material
Copper
Poles
2
Series
K675
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Junction 2-Point
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
9.8500 L
Package Weight (Metric)
4.4680 kg
900 Amp, 35kV, 600 Series Elbow with Test Point Housing only, with Stud.

776BLR

900 Amp, 35kV, 600 Series Elbow with Test Point Housing only, with Stud.
600 Series Elbow with out Test Point, With Stud, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

K655BLR-H0270

600 Series Elbow with out Test Point, With Stud, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
15/25kV,900A DB, 2-Point Junction

K675-J2

15/25kV,900A DB, 2-Point Junction
900 Amp, 4 point junction, Copper, with rubber junction, stainless steel mounting plate, back plate and adjustable mounting bracket

K675-J4-U

900 Amp, 4 point junction, Copper, with rubber junction, stainless steel mounting plate, back plate and adjustable mounting bracket
600 Amp, DeadBreak, 15/25KV, Access Elbow, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

K655ALR-H0270

600 Amp, DeadBreak, 15/25KV, Access Elbow, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
600 Amp, DeadBreak, 15/25KV, Access Elbow, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

K655ALR-HO270

600 Amp, DeadBreak, 15/25KV, Access Elbow, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
600 Amp, Straight Receptacle Housing Only, 15/25 KV, DeadBreak, Without the Bolt and Washers

K655YBSRN

600 Amp, Straight Receptacle Housing Only, 15/25 KV, DeadBreak, Without the Bolt and Washers
600 Amp, Extended Connector Plug, DeadBreak, 15/25KV. Widest Diameter 3 inches. Center Body Length 5.5 inch.

K650ECP

600 Amp, Extended Connector Plug, DeadBreak, 15/25KV. Widest Diameter 3 inches. Center Body Length 5.5 inch.

Frequently Asked Questions

What are the main features of the K675J2 junction?

The K675J2 is a 15/25kV, 900 Amp Deadbreak 2-Way Junction with a fully shielded, submersible molded rubber housing.

What is the 15kV class maximum operating voltage?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and phase-to-phase is 14.4kV.

What is the momentary current rating?

The momentary current rating for the junction is 25kA Symmetrical for 10 cycles.

What is the continuous current rating of the junction?

The continuous current rating for the K675J2 junction is 900 Amp.

What is the 28kV class impulse withstand rating?

For the 28kV voltage class, the impulse withstand (BIL) is 140kV (1.2 x 50 microsecond wave).

What is the 28kV class maximum operating voltage?

For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV and phase-to-phase is 28kV.

What is the 15kV class impulse withstand rating?

For the 15kV voltage class, the impulse withstand (BIL) is 95kV (1.2 x 50 microsecond wave).

What standard does the K675J2 junction meet?

The K675J2 meets ANSI/IEEE Standard 386, Latest Revision.

How is the K675J2 junction mounted?

It is equipped with a stainless steel mounting bracket and back plate suitable for mounting on a flat surface.

What Elastimold products are compatible with the K675J2?

It mates with Elastimold 900 A Series Elbow connectors, K675 Elbow Connector, K675BE Bushing Extender, and 675BEA3 Bushing Adapter.

How to Install K675-J2-5 Deadbreak Junctions

This guide provides comprehensive instructions for safely installing Elastimold 600/900 Ampere deadbreak junctions (K675-J2-5 series), including mounting, grounding, and preparing for operation across various mounting configurations.

Estimated time: 1h

Tools needed:

Wrench set, Wire strippers, Marking tool

Supplies needed:

Elastimold Deadbreak Junction (K675-J2-5 series), Mounting Hardware Prepack (brackets, screws, nuts, washers), Suitable fasteners (user-supplied), Grounding wire (No. 2 solid to 1/0 stranded), ELASTIMOLD approved lubricant, HV Insulated caps

  1. Prepare for Installation and Mark Mounting Location

    De-energize all apparatus and ensure the work area is safe. This product should only be installed by competent personnel trained in good safety practices involving high voltage electrical equipment. Determine the desired location for the junction assembly. Using the base plate or hold-down bracket(s) as a template, mark the slot or hole locations on the mounting surface.

  2. Mount the Brackets to the Surface

    Attach the appropriate mounting brackets (Universal, 45° Fixed, or Hold Down) to the marked surface using suitable fasteners. For Universal mounts, attach the first two brackets, then attach the remaining two at the desired angle using supplied hardware. Tighten all fasteners securely to prevent movement during operation.

  3. Assemble and Attach the Deadbreak Junction

    Assemble the deadbreak junction to the base bracket assembly and base plate using the supplied 1/2” hex head cap screws, split lock washers, and hex nuts, attaching them to the center mounting holes. Then, attach the complete junction assembly to the previously mounted brackets using the supplied hardware. Ensure the parking stand is in the upright position and tighten all fasteners securely.

  4. Ground the Junction Assembly

    Ground the base bracket assembly and the junction’s black conductive jacket. A grounding lug is provided on the base bracket, accommodating wire sizes from No. 2 solid to 1/0 stranded. If mounting without a base bracket, ensure the conductive jacket and shield plate are grounded through contact with a grounded conductive mounting surface, or attach a grounding lug to a bracket bolt.

  5. Prepare for Operation

    Remove all protective shipping caps and clean the operating interfaces. Lubricate each interface with an ELASTIMOLD approved lubricant; do not substitute, as other lubricants may be harmful. If not all operating interfaces will be utilized, install appropriate HV insulated caps on the unused bushings before energization. Do not use protective shipping caps for this function as they are not insulated.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.