Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Voltage rating: 15/25 kV
- Current rating: 900 A
- 2-pole configuration for medium-voltage applications
- Dead break connection type for safe energized terminations
- Designed for power substations, industrial plants, and heavy-duty electrical distribution networks
Specifications
Application | 15/25 kV, 900 Amps |
Material | Copper |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Junction 2-Point |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 13.8500 L |
Package Weight (Metric) | 6.2820 kg |

K675-J4-U
900 Amp, 4 point junction, Copper, with rubber junction, stainless steel mounting plate, back plate and adjustable mounting bracket
K650ECP
600 Amp, Extended Connector Plug, DeadBreak, 15/25KV. Widest Diameter 3 inches. Center Body Length 5.5 inch.
K655VSL2-DP0592392
600 Amp, 2 Way Vault Stretcher Kit, 15/25KV, G0260 - Cable Insulation Diameter 0.760 inch to 0.950 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 3/0 or Compacted/Solid 4/0. J0270 - Cable Insulation Diameter 0.980 inch to 1.180 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 4/0 or Compacted/Solid 250. SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring. (K655VS-L2-G0260-J0270-SG3).
K655BLR-N0400
600 Series Elbow with out Test Point, With Stud, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 900 /Solid 1000 /mmSquared 500.
K655BLR-K0320
600 Series Elbow with out Test Point, With Stud, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 450 /Solid 500/550.Frequently Asked Questions
How do I order the K675J2 with specific mounting options?
Specify K675J2 for the basic junction. Add "-5" for "U" style mounting straps only, or "-6" for the mounting bracket and back plate only.
What items are included in the K675J2 kit?
Each kit contains one basic molded junction K675J2, mounting hardware, two tubes of lubricant, installation instructions, and two protective caps.
Where can the ELASTIMOLD® junctions be used?
ELASTIMOLD® junctions are designed for subsurface, vault, or padmount applications. They can be used for sectionalizing, looping, tapping, and equipment bypass.
What is the K675J2 product?
The K675J2 is a 15/25kV, 900 Amp Deadbreak 2-Way Junction. It features a fully shielded, fully submersible molded rubber housing.
What elbow connectors are compatible with the K675J2?
The K675J2 provides mating for Elastimold® 900 A Series Elbow connectors. It also mates with the K675 Elbow Connector.
What other ELASTIMOLD® products are compatible with this junction?
The junction is designed to mate with ELASTIMOLD® products including the K675BE Bushing Extender and the 675BEA3 Bushing Adapter.
How is the K675J2 junction mounted?
ELASTIMOLD® junctions are equipped with a stainless steel mounting bracket and back plate suitable for mounting on a flat surface.
Which industry standard does the K675J2 meet?
The K675J2 meets ANSI/IEEE Standard 386, Latest Revision.
What is the maximum operating voltage for the 15kV class?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.
What is the continuous current rating for the K675J2?
The K675J2 has a continuous current rating of 900 Amps for both 15kV and 28kV voltage classes.
How to Install Elastimold Deadbreak Junctions (K675-J2, J3, J4)
This guide provides instructions for safely installing and preparing Elastimold 15/25/35kV, 600/900 Ampere Deadbreak Junctions for operation, including mounting, grounding, and initial setup procedures.
Estimated time: 1h
Tools needed:
Wrench, Wire strippers, Torque wrench, Measuring tape
Supplies needed:
Suitable fasteners (for mounting to surface), 3/8 inch Hex Head Cap Screws, External Tooth Lock Washers (3/8 inch), 3/8 inch Hex Nuts, 1/2 inch Hex Head Cap Screws, 1/2 inch Split Lock Washers, 1/2 inch Hex Nuts, Grounding wire (No. 2 solid to 1/0 stranded), ELASTIMOLD approved lubricants, HV insulated caps
- Review Safety and De-energize Apparatus
Before beginning installation, ensure all apparatus is de-energized. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices. Failure to follow instructions can result in serious injury or product damage. Do not touch or move energized products.
- Determine Mounting Location and Mark
Determine the desired location for the junction assembly. Using the base plate as a template, place it on the mounting surface and mark all necessary slot locations for fasteners.
- Mount the Universal Brackets
Attach two universal brackets to the flat surface using suitable fasteners. Tighten them securely to prevent movement during operation. Then, attach the remaining two universal brackets to the first pair at the desired angle using the supplied 3/8 inch hex head cap screws, external tooth lock washers, and 3/8 inch hex nuts. Tighten securely.
- Assemble Junction to Base Bracket and Base Plate
Assemble the deadbreak junction to the base bracket assembly and base plate. Use two 1/2 inch hex head cap screws, two 1/2 inch split lock washers, and two 1/2 inch hex nuts, attaching them to the center mounting holes on the bracket assembly. Tighten securely.
- Attach Junction Assembly to Mounted Brackets
Attach the complete deadbreak junction assembly to the previously mounted universal brackets using the supplied 1/2 inch hex head cap screws, 1/2 inch split lock washers, and 1/2 inch hex nuts. Ensure the parking stand is in an upright position and tighten all hardware securely.
- Ground the Junction Assembly
The base bracket assembly and the junction's black conductive jacket must be grounded. Connect a grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket. Ensure a secure, low-resistance connection to an earth ground.
- Prepare Operating Interfaces
Remove all protective shipping caps from the operating interfaces. Clean each interface thoroughly and lubricate with an ELASTIMOLD approved lubricant. Do NOT substitute other lubricants, as they may harm the product or its mating parts.
- Install Insulated Caps on Unused Bushings
If not all operating interfaces will be utilized, install appropriate HV insulated caps on the unused bushing(s) before energizing the circuit. Do not use the protective shipping caps for this purpose, as they are not insulated.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.