ABB - Installation Products 675CETPM5380 - 15kV, 200/900 Amp Series Loadbreak, Combo-T Elbow with 200 Amp Reducing Tap Plug, Stud, Cable Adapter and Lug Kit without Test Point. Cable Insulation Diameter 1.370-1.630 inches. Copper Lug, 380-Conductor Size 700/750 kcmil Stranded/Compressed or 900 kcmil Solid/Compact. Includes Elbow Housing, Stud, Bi-Metal Compression Lug, Tube of Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. No Sealing Kit.

ABB Installation Products 675CETPM5380 15kV, 200/900 Amp Series Loadbreak, Combo-T Elbow with 200 Amp Reducing Tap Plug, Stud…

UPC: 783786533138


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 675CETPM5380 15kV Loadbreak Elbow Kit is a high-reliability electrical connector designed for medium-voltage power distribution systems. This kit provides a 200/900 Amp rated loadbreak interface with a 15kV voltage class, meeting ANSI/IEEE Standard 386 requirements. It accommodates cable insulation diameters from 1.370 to 1.630 inches, making it suitable for 700/750 kcmil stranded/compressed or 900 kcmil solid/compact copper conductors. Key components include a bi-metal compression lug for copper compatibility, elbow housing, stud, lubricant, cable adapter, installation instructions, and crimp chart. The kit does not include a test point or sealing kit, optimizing it for applications where these features are unnecessary. The loadbreak interface is engineered for energized operation, allowing safe disconnection under load conditions with a 200 Amp continuous and loadbreak rating. Electrical ratings include 8.3kV maximum phase-to-ground operating voltage, 14.4kV maximum phase-to-phase, 95kV BIL impulse withstand, and 34kV AC one-minute withstand. The design incorporates peroxide-cured insulation and jacket for enhanced durability. Installation requires the 600ATM assembly tool, ensuring proper torque application via the included hex-broach feature. This elbow kit serves as a direct replacement for standard loadbreak connectors in utility, industrial, and commercial power distribution systems. Its compatibility with mating products such as 167DR, 167DRG, and 165LR series ensures seamless integration into existing infrastructure. The comprehensive installation guide and crimp chart minimize field errors and reduce downtime during deployment.
  • 15kV voltage class, 200/900 Amp loadbreak interface
  • Accommodates 1.370-1.630" cable insulation diameter
  • Bi-metal compression lug for 700/750 kcmil stranded or 900 kcmil solid copper conductors
  • Includes elbow housing, stud, lubricant, cable adapter, installation instructions, and crimp chart
  • Meets ANSI/IEEE Standard 386; 95kV BIL impulse withstand rating

Specifications

Amperage Rating
900 A
Application
900 Amps, 15kV Connector
Color
Black
Conductor Range
700 to 750 kcmil , 900 kcmil
Connection Type
Compression Lug
Current Rating
200/900 A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Copper Lug, Bi-Metal Compression Lug
Material
Housing - EPDM-Rubber
Series
Combo-T Elbow
Size
1.370-1.630 inches (Cable Insulation Diameter)
Special Features
Reducing Tap Plug with Stud
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
ComboT Elbow
Voltage Rating
15 kV
Width
13.31 in
Width
338.074 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Shrink-Fit Jacket Seal Kit.

655CETPNM0380S

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Shrink-Fit Jacket Seal Kit.
900 Amp, 15kV, Combo T Connector, Copper, carries current.

675BCETP

900 Amp, 15kV, Combo T Connector, Copper, carries current.
15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

656CETP-N0410

15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. 200ECS-G3 Jacket Seal and Grounding Kit Included.

656CETP-M0410

15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. 200ECS-G3 Jacket Seal and Grounding Kit Included.
15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

656CETP-M0380

15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

656CETP-M0380-DRG

15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

656CETP-L0330

15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
15kV, 600 Series ComboT Elbow with 200 Amp Reducing Tap Plug, Stud, Cable Adapter and Lug Kit with Test Point and Seal. Cable Insulation Diameter 1.180 - 1.465 inches (30.0-37.2mm). Aluminum Compression Lug. Conductor Size 330 - 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Stud, Lug, Tube of Lubricant, Cable Adapter, Crimp Chart and Installation Instructions.

656CETP-L0330-S

15kV, 600 Series ComboT Elbow with 200 Amp Reducing Tap Plug, Stud, Cable Adapter and Lug Kit with Test Point and Seal. Cable Insulation Diameter 1.180 - 1.465 inches (30.0-37.2mm). Aluminum Compression Lug. Conductor Size 330 - 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Stud, Lug, Tube of Lubricant, Cable Adapter, Crimp Chart and Installation Instructions.

Frequently Asked Questions

How much does the ComboT reduce stack height?

Each combination elbow/connecting plug reduces stack height by 2.67 inches.

What tools are needed for ComboT installation?

The ComboT installs with standard assembly tools and uses a standard 600 or 900 series stud.

How does the 25 kV reducing tap prevent flashover?

The 25 kV reducing tap includes vents to prevent partial-vacuum flashover.

What are the voltage ratings for CETP connectors?

CETP connectors are available in 15 kV and 25 kV voltage classes. The maximum phase-to-ground operating voltage is 8.3 kV for 15 kV and 15.2 kV for 25 kV.

What is the continuous current rating for CETP connectors?

CETP connectors have continuous current ratings of 600 A for deadbreak and 200 A for loadbreak, or 900 A for deadbreak and 200 A for loadbreak.

What is the loadbreak switching current for CETP?

The loadmake/loadbreak switching current for CETP connectors is 200 A.

What are the voltage ratings for CCP/CBW connectors?

CCP/CBW connectors have a voltage class of 15/25/28 kV. The maximum phase-to-ground operating voltage is 16.2 kV.

What is the continuous current rating for CCP/CBW?

CCP/CBW connectors have continuous current ratings of 600 A or 900 A.

What stud size is used for ComboT assembly?

ComboT assembly utilizes a standard 5/8 inch–11 stud that threads into the equipment bushing.

What is a critical safety step before ComboT installation?

The system must be de-energized before initiating any ComboT installation. Always refer to the complete instruction sheet.

How to Install 675/676CETP Deadbreak Elbow Connectors

A comprehensive guide for the safe and proper installation of 675/676CETP deadbreak elbow connectors, including cable preparation, lug crimping, and final connection to mating apparatus.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Cutting tool, Wire brush (for aluminum conductors), Crimping tool, Torque wrench (or 600AT/600ATM assembly tools), Suitable grounding connector

Supplies needed:

675/676CETP Deadbreak Elbow Connector kit (Elbow, Cable Adapter, Compression Lug, Lubricant), Cable (appropriate type for the connector), Vinyl plastic tape (if applicable for cable shield), Tape marker, Grounding wire (minimum No. 14 AWG Copper), HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. Perform Initial Safety Checks and Preparation

    DANGER: De-energize all apparatus before beginning installation or removal of parts. Inspect all components for damage, proper rating, and compatibility with mating parts. If the product was supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit. Ensure all required tools are at hand and maintain cleanliness throughout the procedure.

  2. Position and Cut the Cable

    Position the cable in its final assembled location, ensuring enough slack to allow adequate clearance for removing the elbows. If using concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4 inches (45mm) from the center line of the mating product.

  3. Clean the Cable Outer Surface

    Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent back concentric neutral wires.

  4. Prepare the Cable Shield and Jacket

    Remove the outer jacket to the dimension shown in the product documentation. Fold back any shield wires. Based on your cable type (e.g., flat metallic tape, fabric tape, longitudinally corrugated, semi-con), remove the shield and install a tape marker or retainer as instructed. If using UNISHIELD or lead sheath cable, refer to the 10TL cable shield adapter instructions for specific preparation and grounding. CAUTION: Do not cut or nick the cable insulation when removing the semi-con shield.

  5. Prepare Cable Insulation and Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation using the supplied lubricant, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  6. Prepare Conductor Length

    Remove any protruding cable insulation by cutting it even with the end of the cable adapter. CAUTION: Do not cut or nick the cable adapter or the conductor. VERIFY: The exposed conductor length is between 4 3/8 inches and 4 11/16 inches (111mm–119mm). If the length is outside this range, redo the assembly.

  7. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. VERIFY: The 'Check Dimension' before crimping is less than 6 1/2 inches (165mm). If not, redo the assembly. Crimp the compression lug following the crimping instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. VERIFY: The distance from the end of the compression lug to the cable adapter after crimping is between 6 1/2 inches and 7 1/4 inches (165mm–184mm). If not, redo the assembly.

  8. Install the Elbow onto the Cable Adapter

    Lubricate the cable adapter and the inside of the elbow cable entrance using the supplied lubricant. Install the elbow onto the cable adapter until the elbow cannot advance further. VERIFY: The cable adapter remains flush with the tape marker. Reposition the cable adapter if necessary. Remove the tape marker.

  9. Prepare Mating Products and Install Stud

    DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove any protective caps from the elbow and the mating part. Install the stud into the apparatus by hand until it is fully seated. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.

  10. Connect the Elbow to the Mating Part

    Push the elbow onto the mating part. Using the appropriate assembly tool (600AT for products dated September 30, 2013 or earlier, or 600ATM for products dated October 1, 2013 or later), engage the hex broach in the contact assembly. Insert the contact assembly into the elbow interface to engage the stud. For older products, torque the contact assembly until the 600AT torque limiter ratchets (19 to 25 foot/pounds torque). For newer products, tighten the contact assembly to 50-60 foot/pounds torque. CAUTION: Do not exceed 60 foot/pounds torque for newer products.

  11. Ground the Cable Shield

    Insert one end of a wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop. Do not damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; ground it according to the instructions supplied with your grounding device, or through an alternate method if no grounding device is used. RECOMMENDATION: Waterproof the jacket of the cable at this point to prevent moisture from entering the cable.

  12. Verify Seating Indication

    VERIFY: Complete assembly of an insulated cap or elbow is indicated by no portion of the colored interface sleeve being visible when viewed from the side.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.