ABB - Installation Products K656LR-N0300 - Elbow Connector with Test Point, 600 Amp, Dead Break, 15/25 KV, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 350 or Solid 400 or mm2 Compact 185.

ABB Installation Products K656LR-N0300 Elbow Connector with Test Point, 600 Amp, Dead Break, 15/25 KV, Cable Insulation…

UPC: 783786514120


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656LR-N0300 is a dead-break elbow connector engineered for reliable 15/25 kV medium-voltage cable terminations up to 600 Amps. Designed for fully shielded, dead-front submersible applications, this connector ensures safe, insulated connections in power distribution systems. The K656LR-N0300 features a non-corrosive capacitive test point for system diagnostics without de-energizing the circuit, enabling efficient troubleshooting and maintenance. Key specifications include a voltage rating of 15/25 kV with a maximum phase-to-ground operating voltage of 8.3 kV and phase-to-phase of 14.4 kV. It supports continuous current ratings of 600 Amps and withstands momentary fault currents up to 25 kA for 10 cycles. The connector accommodates cable insulation diameters from 1.515 inches to 1.780 inches, making it compatible with compressed/stranded AWG 350, solid AWG 400, or compact mm² 185 conductors. Its fully molded rubber housing, constructed from 100% peroxide-cured EPDM materials, provides robust environmental resistance and submersibility. The K656LR-N0300 is ideal for applications requiring secure, insulated connections in medium-voltage power distribution networks, including utility substations, industrial facilities, and renewable energy installations. Its dead-break design allows safe connection and disconnection under de-energized conditions using standard hand tools, reducing downtime and enhancing operational safety. The aluminum compression lug ensures a secure conductor termination, while the capacitive test point enables non-invasive system diagnostics.
  • 600 Amp continuous current rating for medium-voltage applications
  • 15/25 kV voltage class with 8.3 kV phase-to-ground operating voltage
  • Cable insulation diameter range: 1.515" to 1.780"
  • Supports AWG 350 (compressed/stranded), AWG 400 (solid), or mm² 185 (compact) conductors
  • Non-corrosive capacitive test point for safe system diagnostics

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amp Deadbreak Elbow Connection
Color
Black
Conductor Range
300 kcmil , 350 kcmil
Connection Type
Dead Break
Current Rating
600 A
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
600 Series
Size
Cable Insulation Diameter 1.515 inch to 1.780 inch
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected using Standard Hand Tools and Equipment in a De-Energized State. Non-Corrosive, Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
25 kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
6.4000 L
Package Weight (Metric)
2.9030 kg
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.

K655LR-K0290

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG Compressed/Stranded 4/0 or kcmil Compact/Solid 250 or mm2 Compact 125. Cold-Shrinkable Jacket Seal Included.

K655LR-J0270-S

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG Compressed/Stranded 4/0 or kcmil Compact/Solid 250 or mm2 Compact 125. Cold-Shrinkable Jacket Seal Included.
600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 1000. 200ECS Jacket Seal Included.

K655LR-N0410-S

600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 1000. 200ECS Jacket Seal Included.
600 Amp, 15-25kv Dead Break Elbow, Cable Insulation .850-1.050 inches, Aluminum Compression Lug, Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

K655LR-H0330

600 Amp, 15-25kv Dead Break Elbow, Cable Insulation .850-1.050 inches, Aluminum Compression Lug, Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed/Stranded 4/0 or kcmil Compact/Solid 250 or mm2 Compact 125.

K655LR-H0270

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed/Stranded 4/0 or kcmil Compact/Solid 250 or mm2 Compact 125.
600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 700/750 or Compact/Solid 900. 200ECS Jacket Seal Included.

K655LR-M0380-S

600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 700/750 or Compact/Solid 900. 200ECS Jacket Seal Included.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG Compressed/Stranded 4/0 or kcmil Compact/Solid 250 or mm2 Compact 125.

K655LR-J0270

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG Compressed/Stranded 4/0 or kcmil Compact/Solid 250 or mm2 Compact 125.

Frequently Asked Questions

What is the maximum operating voltage for the K656LR elbow connector?

The K656LR is designed for up to 28kV phase-to-phase and 16.2kV phase-to-ground.

What conductor sizes can the K656LR accommodate?

It supports conductor sizes from #2 AWG to 1250 kcmil for both aluminum and copper.

What is the insulation diameter range for this elbow connector?

The insulation diameter range is from 0.640 inches to 1.935 inches.

What standards does the K656LR meet?

The K656LR meets ANSI/IEEE Standard 386, Latest Revision.

What is the continuous current rating for the K656LR?

The continuous current rating for the K656LR is 600 Amps.

What is the impulse withstand rating for the 28kV voltage class?

For the 28kV voltage class, the impulse withstand is 140kV BIL (1.2 x 50 microsecond wave).

What is the AC one-minute withstand for the 15kV voltage class?

The AC one-minute withstand for the 15kV voltage class is 34kV.

What is the corona extinction level for the 28kV voltage class?

The corona extinction level for the 28kV voltage class is 21.5kV AC at 3pC sensitivity.

What is the momentary current rating for the K656LR?

The momentary current rating is 25kA Sym for 10 Cycles.

Is a grounding device recommended for this product?

Yes, an ECS cable seal grounding device is highly recommended for safety when used on metallic tape shield or drain wire cable.

How to Install Elastimold 655/675LR and K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of Elastimold 655/675LR and K655/K675LR deadbreak elbow connectors on 15kV and 25kV class systems. It covers cable preparation, component assembly, and grounding procedures.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Measuring tape or ruler, Crimping tool, Wire brush, Hotstick, Suitable sensing device for capacitive test points, Torque wrench

Supplies needed:

Elastimold 655/675LR or K655/K675LR Deadbreak Elbow Connector kit (Elbow, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Stud Prepack), Cable (concentric neutral, jacketed, unishield, or lead sheath type), Mating high voltage apparatus or connector, Grounding device (e.g., 20MA, 21MA, 600ECS Jacket Cable Seal, or alternate method), Silicone lubricant, No. 14 AWG Copper wire (or equivalent ampacity for grounding), Suitable connector for grounding wire, HV insulated cap(s) or connector(s) (if replacing shipping covers), Tape marker, Waterproofing material for cable jacket

  1. De-energize Apparatus and Inspect Parts

    DANGER: All apparatus must be de-energized during installation or removal of part(s). Do not touch or move energized products in the work area. Inspect all parts for damage, proper rating, and compatibility with mating parts. If the product is supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit. Verify that all package contents are complete and undamaged, and that all components fit properly with the cable and/or mating products.

  2. Prepare Cable for Assembly

    Assemble the cable in its final position with enough slack to allow for elbow removal. If using concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent back concentric neutral wires. Refer to specific instructions for your cable type (e.g., 20MA/21MA grounding device, 600ECS Jacket Cable Seal, UNISHIELD/LEAD SHEATH with 10TL adapter, or jacketed/non-jacketed cable) to remove the outer jacket and prepare the cable shield as shown in the provided diagrams.

  3. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare Conductor Length

    Remove any protruding cable insulation by cutting it even with the end of the cable adapter. Exercise caution to avoid cutting or nicking the cable adapter or the conductor. Verify that the length of the exposed conductor is between 4-1/4 inches and 4-9/16 inches (108mm-116mm). If the length is outside this range, redo the assembly.

  5. Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Measure the 'Check Dimension' before crimping; this dimension must be less than 6-3/8 inches. Crimp the compression lug according to the instructions supplied with the lug. After crimping, wipe off all excess inhibitor from the compression lug and cable adapter surface. Verify that the distance from the end of the compression lug to the cable adapter is between 6-3/8 inches and 7-1/8 inches (162mm-181mm). If any dimension is incorrect, redo the assembly.

  6. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter, pushing until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; if not, reposition the cable adapter. Once correctly positioned, remove the tape marker.

  7. Prepare Mating Product

    DANGER: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove any protective caps from both the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring all surfaces remain clean.

  8. Connect Elbow to Mating Product

    Push the elbow onto the mating part, carefully aligning the hole in the compression lug with the stud on the mating part.

  9. Connect Opposite End Mating Product (if applicable)

    Clean and lubricate the mating part intended for the opposite end of the elbow. Insert this mating part into the elbow. Engage the threads and hand tighten. Torque the mating part according to the specific instructions supplied with that mating part. CAUTION: When constructing 600amp L-Kits, ensure each component is tightened to its specified torque.

  10. Install Insulating Plug or Voltage Detection Cap (if applicable)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap onto the elbow and push down firmly until it snaps into place. Follow the voltage test directions provided in the next step.

  11. Ground the Cable Shield

    Insert one end of a piece of wire, with ampacity at least equivalent to No. 14 AWG Copper, through the grounding eye and twist it to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow the instructions supplied with your grounding device. If no grounding device is used, ground the shield through an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  12. Perform Voltage Test

    Remove the test point cap using a hotstick, peeling it off at an angle rather than pulling directly in line with the test point assembly. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment; follow the manufacturer’s directions for the specific meter used. Test with a suitable sensing device designed for separable connectors with capacitive test points to determine if the cable is energized. Contamination, moisture, dirt, or incorrect equipment can cause a false 'no voltage' indication. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious or fatal injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.