- 15/25 kV voltage rating for medium-voltage applications
- Accommodates 1000 kcmil compressed or stranded aluminum conductors
- Suitable for cable insulation diameters from 1.515 to 1.780 inches
- Includes aluminum compression lug for secure, low-resistance connections
- Fully shielded, dead-front, and submersible design meeting ANSI/IEEE Standard 386
Specifications
Amperage Rating | 600 A |
Application | Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus |
Color | Black |
Conductor Range | 1000 kcmil |
Environmental Conditions | Fully Submersible |
Insulation | True |
Length | 13 in |
Length | 330.2 mm |
Material | Housing - EPDM-Rubber |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector |
Voltage Rating | 15 to 25 kV |
Width | 10.36 in |
Width | 263.144 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 7.2500 L |
Package Weight (Metric) | 3.2890 kg |

K656CETPN0410
15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
K655LR-H0330
600 Amp, 15-25kv Dead Break Elbow, Cable Insulation .850-1.050 inches, Aluminum Compression Lug, Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
K655LR-H0270
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed/Stranded 4/0 or kcmil Compact/Solid 250 or mm2 Compact 125.
K655LR-M0380-S
600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 700/750 or Compact/Solid 900. 200ECS Jacket Seal Included.
K655LR-J0270
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG Compressed/Stranded 4/0 or kcmil Compact/Solid 250 or mm2 Compact 125.
K655LR-H0240
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.
K655LR-J0330
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
K655LR-G0250
600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, 600 Amp, Dead Break, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 2/0 or Solid/Compact 3/0 or mm2 70.Frequently Asked Questions
What is the maximum operating voltage for this elbow connector?
The elbow connector can be used through 28kV, with a maximum phase-to-ground operating voltage of 16.2kV and a maximum phase-to-phase voltage of 28kV.
What conductor sizes can this elbow connector accommodate?
It accommodates conductor sizes from #2 AWG to 1250 kcmil for both aluminum and copper conductors.
What is the acceptable range for cable insulation diameters?
The insulation diameters can range from 0.640 inches to 1.935 inches.
What is the continuous current rating for this connector?
The connector has a continuous current rating of 600 Amps.
What is the momentary current withstand rating?
It can withstand 25kA symmetrical for 10 cycles momentarily.
What is the impulse withstand rating (BIL) for 28kV class?
For the 28kV voltage class, the impulse withstand (BIL) is 140kV.
What is the AC one-minute withstand voltage for 15kV class?
For the 15kV voltage class, the AC one-minute withstand voltage is 34kV.
What is the AC corona extinction voltage for 28kV class?
The AC corona extinction voltage for the 28kV class is 21.5kV at 3pC sensitivity.
What is the purpose of the K655LR elbow connector?
It is designed to provide fully shielded, dead-front submersible cable connections to high-voltage apparatus.
What standards does this elbow connector meet?
The Elastimold® K655LR meets ANSI/IEEE Standard 386, Latest Revision.
How to Install Elastimold 655/675LR and K655/K675LR Deadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and connection of Elastimold 655/675LR and K655/K675LR deadbreak elbow connectors on high voltage systems.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Crimping tool, Wire brush, Torque wrench, Hotstick, Suitable sensing device for capacitive test points
Supplies needed:
Elbow connector, Cable adapter, Compression lug, Insulating plug (optional), Lubricant, Threaded stud (if mating part not equipped), No. 14 AWG Copper wire (or equivalent ampacity), Suitable grounding connector, Silicone lubricant, Crimp chart
- De-energize and Inspect Components
Before beginning any work, ensure all apparatus in the work area is completely de-energized. Do not touch or move energized products. Inspect all components (elbow, cable adapter, compression lug, insulating plug, lubricant, stud prepack) for damage, correct rating, and compatibility with mating parts. Read all instructions thoroughly before starting the procedure.
- Prepare the Cable
Assemble the cable in its final position with enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the center line of the mating product. Clean the outer surface of the cable for 24” (610mm) or up to the bent back concentric neutral wires. Remove the outer jacket (if applicable) and prepare the cable according to the specific cable type as shown in the provided diagrams, ensuring correct insulation, semi-con shield, and tape marker dimensions.
- Install Cable Adapter and Prepare Conductor
Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker. Remove the protruding cable insulation by cutting it even with the end of the cable adapter, being careful not to cut or nick the cable adapter or conductor. Verify the exposed conductor length is between 4-1/4” – 4-9/16” (108mm-116mm); if not, redo the assembly.
- Crimp the Compression Lug
For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Measure the 'Check Dimension' before crimping; it must be less than 6-3/8”. Crimp the compression lug following the instructions supplied with the lug. After crimping, wipe all excess inhibitor from the compression lug and cable adapter surface. The distance from the end of the compression lug to the cable adapter should be between 6-3/8” to 7-1/8” (162mm-181mm); if not, redo the assembly.
- Install the Elbow Connector
Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.
- Connect to Mating Product
WARNING: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from the elbow and mating part. If the mating part lacks a stud, hand tighten the supplied threaded stud into it. Clean and lubricate both the elbow and mating part. Push the elbow onto the mating part, aligning the compression lug hole with the stud. Clean and lubricate the opposite mating part, insert it into the elbow, engage threads, and hand tighten. Torque the mating part per its instructions. If using an insulating plug, clean/lubricate its voltage detection cap and snap it onto the elbow.
- Ground the Cable Shield
Insert one end of a No. 14 AWG Copper wire (or equivalent ampacity) through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow instructions supplied with a grounding device, or use an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.
- Perform Voltage Test (Optional but Recommended)
The ELASTIMOLD elbow has a capacitance test point to check if the circuit is energized. Remove the test point cap with a hotstick, peeling at an angle. WARNING: This is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device for capacitive test points, following its directions. Contamination or incorrect equipment can cause a false 'no voltage' indication. Treat the elbow as energized until 'no voltage' is confirmed by other means to prevent serious injury. After testing, clean and lubricate the cap with silicone lubricant and replace it.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.