ABB - Installation Products K656LR-N0280 - 15/25kV, 600 Amp, DeadBreak, Elbow with Test Point (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation 1.515-1.780 inches, Aluminum Compression Lug, Conductor Size 250 Stranded/Compressed
ABB - Installation Products

K656LR-N0280

UPC: 075114304313


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Overview

The ABB K656LR-N0280 is a 15/25kV, 600 Amp DeadBreak Elbow connector designed for medium-voltage cable systems. This deadbreak elbow includes a test point for safe voltage verification without cable de-energization, making it ideal for switchgear, transformers, and underground distribution applications. The connector accommodates cable insulation diameters between 1.515-1.780 inches and is compatible with 250 stranded/compressed aluminum conductors. Supplied with an insulated plug, protective cap, compression lug, and cable adapter, the K656LR-N0280 ensures reliable electrical connection and mechanical integrity in harsh environments. The aluminum compression lug provides superior conductivity and corrosion resistance, while the deadbreak design allows for hot stick operation and safe maintenance. This connector is engineered for use in utility, industrial, and commercial power distribution systems where reliability and safety are critical.
  • Rated for 15/25kV, 600 Amp operation
  • DeadBreak design enables safe hot stick operation
  • Includes test point for voltage verification without de-energization
  • Compatible with 250 stranded/compressed aluminum conductors
  • Cable insulation range: 1.515-1.780 inches

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amp Deadbreak Elbow Connection
Color
Black
Conductor Range
250 kcmil , 300 kcmil
Connection Type
Compression Lug
Current Rating
600 A
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
K656LR
Size
Cable Insulation 1.515-1.780 inches
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected using Standard Hand Tools and Equipment in a De-Energized State. Non-Corrosive, Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
25 kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
6.4200 L
Package Weight (Metric)
2.9120 kg
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 250 or Compact/Solid 300. No Sealing Kit.

K656LR-L0280

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 250 or Compact/Solid 300. No Sealing Kit.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Copper Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0. No Sealing Kit

K656LR-G2240

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Copper Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0. No Sealing Kit
25/28kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Compression Lug, Conductor Size 1/0 Stranded/Compressed, 2/0 Solid/Compact. No Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.

261LR-E5240

25/28kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Compression Lug, Conductor Size 1/0 Stranded/Compressed, 2/0 Solid/Compact. No Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
25/28kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Compression Lug, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. No Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.

261LR-E5270

25/28kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Compression Lug, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. No Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
25/28kV, 200 Amps, Loadbreak Elbow, Built in Jacket Seal, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Compression Lug, Conductor Size 1/0 Stranded/Compressed, 2/0 Solid/Compact. No Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.

261LRJS-E5240

25/28kV, 200 Amps, Loadbreak Elbow, Built in Jacket Seal, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Compression Lug, Conductor Size 1/0 Stranded/Compressed, 2/0 Solid/Compact. No Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
25/28kV, 200 Amps, Loadbreak Elbow, Built in Jacket Seal, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Compression Lug, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. No Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.

261LRJS-E5270

25/28kV, 200 Amps, Loadbreak Elbow, Built in Jacket Seal, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Compression Lug, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. No Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
15/25 kV, 600 Amp, Deadbreak, Elbow Kit, with Insulated Plug, Cap, Stud, Copper Lug, and Cable Adapter. Cable Insulation Diameter 1.515-1.780. Conductor Size kcmil Compressed/Stranded 1000.

K655LR-N2410

15/25 kV, 600 Amp, Deadbreak, Elbow Kit, with Insulated Plug, Cap, Stud, Copper Lug, and Cable Adapter. Cable Insulation Diameter 1.515-1.780. Conductor Size kcmil Compressed/Stranded 1000.

Frequently Asked Questions

What is the maximum current rating of this elbow?

The K656LR-N0280 supports a maximum current rating of 600 Amps.

Does this elbow include a test point?

Yes, the connector includes a test point for safe voltage verification.

Is the K656LR-N0280 a deadbreak connector?

Yes, the K656LR-N0280 is a deadbreak elbow designed for safe hot stick operation.

What voltage rating does the K656LR-N0280 support?

The connector is rated for 15/25kV operation.

What is the cable insulation range for this connector?

The K656LR-N0280 accommodates cable insulation diameters between 1.515 and 1.780 inches.

What accessories are included with the K656LR-N0280?

The connector includes an insulated plug, protective cap, compression lug, and cable adapter.

What conductor size is compatible with this elbow?

The connector is designed for 250 stranded/compressed aluminum conductors.

How to Install Elastimold 655/675LR and K655/K675LR Deadbreak Elbow Connectors

A comprehensive guide for the safe and proper installation of Elastimold 600-ampere and 900-ampere deadbreak elbow connectors on 15kV and 25kV class electrical systems.

Estimated time: 2h

Tools needed:

Cable preparation tools (knife, strippers, beveling tool), Wire brush, Crimping tool, Torque wrench, Hotstick, Suitable capacitive sensing device

Supplies needed:

Elastimold 655/675LR or K655/K675LR connector kit (Elbow, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Stud Prepack, Crimp chart), No. 14 AWG Copper wire (or equivalent ampacity), Suitable ground connector, Silicone lubricant, Waterproofing material for cable jacket

  1. Prepare for Installation and Ensure Safety

    DANGER: De-energize all apparatus before beginning installation or removal of parts. Do not touch or move energized products. Inspect all parts for damage, correct rating, and compatibility with mating parts. Check package contents for completeness and ensure all components fit properly with the cable and/or mating products. Read all instructions thoroughly and have all required tools ready. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.

  2. Prepare the Cable

    Assemble the cable in its final position with enough slack to allow for elbow removal. For concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24” (610mm) or up to the bent-back concentric neutral wires. Remove the outer jacket (where applicable) and prepare the cable insulation and semi-con shield to the specified dimensions indicated by the tape markers (9-3/4”, 10-3/4”, 12-3/4”).

  3. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare the Conductor

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. Verify that the length of the exposed conductor is between 4-1/4” and 4-9/16” (108mm-116mm); if not, redo the assembly.

  5. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the “Check Dimension” before crimping; this dimension should be less than 6-3/8”. Crimp the compression lug following the crimping instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. Verify the distance from the end of the compression lug to the cable adapter is between 6-3/8” to 7-1/8” (162mm-181mm) after crimping; if not, redo the assembly.

  6. Install the Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter is still flush with the tape marker; if not, reposition the cable adapter. Remove the tape marker.

  7. Connect to Mating Product (First End)

    DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from the elbow and the mating part. Hand tighten the threaded stud supplied with the elbow into the mating part, if the mating part is not already equipped with a stud. Clean and lubricate both the elbow and the mating part with the supplied lubricant, keeping surfaces clean. Push the elbow onto the mating part, lining up the hole in the compression lug with the stud on the mating part.

  8. Connect to Mating Product (Opposite End or Tap)

    Clean and lubricate the mating part for the opposite end of the elbow. Insert the mating part into the elbow. Engage the threads and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part. If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow, pushing down hard until the cap snaps into place.

  9. Ground the Cable Shield

    Insert one end of a piece of wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; ground it according to the instructions supplied with the grounding device, or through an alternate method if no grounding device is used. It is also recommended that the jacket of the cable be waterproofed at this point to prevent moisture from entering the cable.

  10. Perform Voltage Test (Optional but Recommended)

    WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the specific meter used. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Contamination, moisture, dirt, or using the wrong measuring equipment can provide a false “no voltage” indication on an energized elbow. To prevent serious or fatal injury, treat the elbow as energized until the “no voltage” test point indication is confirmed by other means. After voltage detection has been made, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.