ABB Installation Products 655CETPNM0380S 600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No…
UPC: 783786084067
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 600 Amp, 15kV voltage rating for medium voltage applications.
- Aluminum construction for robust conductivity and durability.
- Accommodates cable insulation diameters from 1.370" to 1.630".
- Compatible with 700-750 kcmil compressed stranded or 900 kcmil compacted solid conductors.
- Includes cable adapter, lug, and shrink-fit jacket seal kit.
Specifications
Amperage Rating | 600 A |
Application | 600 Amps, 15kV Connector |
Color | Black |
Conductor Range | 700 to 750 kcmil , 900 kcmil |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Housing - EPDM-Rubber |
Special Features | Reducing Tap Plug with Stud, Cable Adapter, and Lug |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | ComboT Elbow |
Voltage Rating | 15 kV |
Width | 13.31 in |
Width | 338.074 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K655LR-P0380
15/25kV 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size kcmil Compressed/Stranded 700/750 or Compact/Solid 900.
655CETPNN0410S
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Shrink-Fit Jacket Seal Kit.
655BCETPN
600 Amp, 15kV, Deadbreak, ComboT Elbow / Reducing Tap Plug (Universal Aluminum), No Test Point. Cable Insulation Diameter 1.515 inch to 1.780 inch.
655BCETP
600 Amp, 15kV, Deadbreak, ComboT Elbow / Reducing Tap Plug (Universal Aluminum), No Test Point.
655CETPN0410
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000.
655CETPM0380
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.370 inch to 1.630 inch.
655CETPN0410DRGS
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Shrink-Fit Jacket Seal Kit.Frequently Asked Questions
What is a critical safety precaution for installation?
The system needs to be de-energized before initiating any installation. Always refer to the complete instruction sheet.
What stud size is used for ComboT assembly?
The ComboT utilizes a standard 5/8 in–11 stud that threads into the equipment bushing.
What is the continuous current rating for CCP/CBW?
The continuous current rating for CCP and CBW is 600 A for the 600 A series and 900 A for the 900 A series.
What are the voltage ratings for CCP and CBW?
The CCP and CBW have a max phase-to-ground operating voltage of 16.2 kV and a max phase-to-phase operating voltage of 28.0 kV.
What is the loadbreak switching current for CETP?
The loadmake/loadbreak switching current for the CETP is 200 A.
What is the continuous current rating for CETP?
The CETP has a continuous current rating of 600 A for deadbreak and 200 A for loadbreak.
What are the 25 kV CETP voltage ratings?
The 25 kV CETP has a max phase-to-ground operating voltage of 15.2 kV and a max phase-to-phase operating voltage of 26.3 kV.
What are the 15 kV CETP voltage ratings?
The 15 kV CETP has a max phase-to-ground operating voltage of 8.3 kV and a max phase-to-phase operating voltage of 14.4 kV.
What are the color codes for ComboT voltage classes?
IEEE 386 color-coded PBT interfaces are red for 15 kV reducing tap and blue for 25 kV reducing tap.
What tools are required for ComboT installation?
The ComboT installs with standard assembly tools and uses a standard 600 or 900 series stud.
How to Install 655/656/675/676CETP Deadbreak Elbow Connectors
This guide provides detailed instructions for the safe installation and wiring of 655/656/675/676CETP deadbreak elbow connectors, ensuring fully shielded and submersible connections to high voltage apparatus. All apparatus must be de-energized during installation.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Crimping tool, Wire brush (for aluminum conductors), 600ATM assembly tool (or 600AT for older products), Hotstick, Suitable voltage sensing device
Supplies needed:
655/656/675/676CETP Elbow Connector kit (includes Elbow, Cable Adapter, Compression Lug, Lubricant), Vinyl plastic tape, Tape retainer (if fabric tape shield), Tape marker, Wire (at least No. 14 AWG Copper equivalent), Suitable ground connector, Insulated cap or appropriate elbow (for final assembly), Silicone grease
- Prepare the Cable for Connection
WARNING: Ensure all apparatus is de-energized before starting. Position the cable in its final assembled position with enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent back concentric neutral wires.
- Prepare the Cable Shield and Jacket
Remove the outer jacket to the specified dimension. Fold back shield wires. Depending on your cable type, remove the flat metallic tape shield and secure with vinyl plastic tape, or remove fabric tape shield and install a tape retainer and tape marker, or remove longitudinally corrugated shield and install a tape marker, or remove semi-con shield and install a tape marker. Do not cut or nick the cable insulation. If using UNISHIELD® or lead sheath cable, refer to the 10TL cable shield adapter instructions for preparation and grounding.
- Install the Cable Adapter
Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation (using supplied lubricant), always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.
- Prepare the Conductor and Crimp Lug
Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The exposed conductor length should be 4-3/8 to 4-11/16 inches (111mm-119mm); otherwise, redo assembly. For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Measure the 'Check Dimension' before crimping (should be less than 6-1/2 inches / 165mm). Crimp the compression lug according to its supplied instructions. Wipe all excess inhibitor from the lug and cable adapter. The distance from the end of the lug to the cable adapter after crimping should be 6-1/2 to 7-1/4 inches (165mm-184mm); otherwise, redo assembly.
- Install the Elbow Connector
Lubricate the cable adapter and the inside of the elbow cable entrance with the supplied lubricant. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.
- Connect to Mating Product
DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from the elbow and the mating part. Install the stud into the apparatus by hand until fully seated. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean. Push the elbow onto the mating part. Using the 600ATM assembly tool (or 600AT for products dated September 30, 2013 or earlier), engage the hex broach in the contact assembly. Insert the contact assembly into the elbow interface to engage the stud. Tighten the contact assembly to 50-60 foot/pounds torque (do not exceed 60 foot-pounds torque). For older products, torque until the 600AT torque limiter ratchets (19-25 foot/pounds).
- Ground the Cable Shield
Insert one end of a wire (at least No. 14 AWG Copper equivalent) through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded according to the instructions supplied with the grounding device, or through an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.
- Complete Loadbreak Interface Assembly (if applicable)
Clean and lubricate the entire loadbreak interface and either a DR(G), ESA, GLR, or LR of the appropriate voltage class with the supplied or ELASTIMOLD® approved lubricant. Install the DR(G), ESA, GLR, or LR to the tap plug interface following their respective instructions.
- Verify Seating Indication
Confirm that the assembly of an insulated cap or elbow is complete by ensuring no portion of the colored interface sleeve is visible when viewed from the side.
- Perform Voltage Test (656CETP only)
If using a 656CETP connector, remove the test point cap with a hotstick by peeling it off at an angle. WARNING: The voltage test point is a capacitance device and not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device made for capacitive test points and follow its manufacturer's directions. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means, as contamination or wrong equipment can give false readings. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.