Authorized ABB Distributor (Installation Products)
ABB - Installation Products K656I-L0330 - 15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

ABB Installation Products K656I-L0330 15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point.…

UPC: 783786852604


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Installation Products K656I-L0330 is a 2-way deadbreak separable straight joint package designed for 15-25kV applications. This kit includes an aluminum compression lug and features a test point for enhanced diagnostics. It is engineered to accommodate cable insulation diameters ranging from 1.180 inches to 1.465 inches. The package supports a broad spectrum of conductor sizes, including compressed stranded 500 kcmil, compacted solid 600 kcmil, and mm² compact sizes of 250/300. This deadbreak joint provides a reliable and secure connection for medium voltage power distribution systems, ensuring operational integrity and ease of maintenance. The inclusion of a test point allows for convenient voltage testing without compromising the integrity of the joint. Manufacturer: ABB - Installation Products. SKU: K656I-L0330. UNSPSC Code: 39121421.
  • 15-25kV voltage rating
  • 2-way deadbreak separable straight joint package
  • Includes test point for diagnostics
  • Aluminum compression lug
  • Accommodates cable insulation diameter 1.180" - 1.465"

Specifications

Amperage Rating
600 A
Application
Compact Design is suitable for small vaults and manholes
Color
Black
Conductor Range
500 kcmil , 600 kcmil
Environmental Conditions
All Weather Conditions
Insulation
True
Length
37.27 in
Length
946.658 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible, 100 percent Peroxide cured Molded EODM Rubber
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Separable Straight Joint
Voltage Rating
15 to 25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K675LR-M2330

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K655YSR-LM0330

600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp, 15/25kV, Separable Wye Joint Kit, 3-Way with Test Point. 2 X ( Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.) 1 X ( Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.)

K656CY-2M0330-J0270

600 Amp, 15/25kV, Separable Wye Joint Kit, 3-Way with Test Point. 2 X ( Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.) 1 X ( Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.)
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

K655YSR-P0410

600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
15-25kV 600 Series Deadbreak Direct Test Straight Receptacle Elbow with Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K656YDSR-M0380

15-25kV 600 Series Deadbreak Direct Test Straight Receptacle Elbow with Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635-0.905 inches (16.13-22.99mm), Bi-Metal Lug, Conductor Size 210 - #3 Stranded/Compressed, #2 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.

252LR-B5210

15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635-0.905 inches (16.13-22.99mm), Bi-Metal Lug, Conductor Size 210 - #3 Stranded/Compressed, #2 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575-0.740 inches (14.61-18.80mm), Bi-Metal Lug, Conductor Size 250 - 2/0 Stranded/Compressed, 3/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.

252LR-A5250

15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575-0.740 inches (14.61-18.80mm), Bi-Metal Lug, Conductor Size 250 - 2/0 Stranded/Compressed, 3/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, (1) M0360 - Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 650 or Compacted Solid 750 or mmSquared Compact 400. (2) L0320 - Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 or Compacted Solid 500/550. Cold Shrinkable Seal with Copper Rod and Crimp Connector Included. K656CY-M0360-L0320-L0320-SG1

K656CY-DP0593491

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, (1) M0360 - Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 650 or Compacted Solid 750 or mmSquared Compact 400. (2) L0320 - Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 or Compacted Solid 500/550. Cold Shrinkable Seal with Copper Rod and Crimp Connector Included. K656CY-M0360-L0320-L0320-SG1

Frequently Asked Questions

Can I order a cable jacket sealing kit?

Yes, a cable jacket sealing kit can be included by adding a suffix symbol to the catalog number.

What is the K656I cable joint used for?

The K656I cable joint is used to join cables in a disconnectable 2-way joint. It is suitable for small vaults, manholes, and direct-buried applications.

Can the K656I joint be used in direct-buried applications?

Yes, the K656I cable joint can be used in direct-buried applications.

What are the operating voltage limits for 15kV class?

For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.

What is the continuous current rating of the joint?

The continuous current rating for both 15kV and 25kV voltage classes is 600 Amps.

What are the impulse withstand ratings?

The impulse withstand (BIL) is 95kV for the 15kV class and 140kV for the 25kV class.

What is the momentary current rating?

The momentary current rating for both 15kV and 25kV voltage classes is 25kA Sym for 10 cycles.

Does the K656I meet industry standards?

Yes, the K656I joint meets ANSI/IEEE Standard 386, Latest Revision.

What material is the K656I joint made from?

The K656I joint is made from 100% peroxide cured EPDM molded rubber.

Does the K656I joint include a test point?

Yes, the K656I joint includes an integral capacitive test point.

How to Install K656 Series Deadbreak Receptacles

This guide provides detailed instructions for the safe and proper installation of K656 series deadbreak receptacles, including cable preparation, crimping, and final assembly for high voltage applications.

Estimated time: 2h

Tools needed:

Hex wrench, Torque wrench with 15/16 inch socket, Wire brush (for aluminum cable), Cable stripping tools (for jacket, semi-con, insulation), Rag, Approved safety solvent, Assembly tool (650ATY or 600RRT)

Supplies needed:

Lubricant (supplied or ELASTIMOLD approved), No. 14 AWG copper wire (or equivalent), HV insulated cap(s) or connector(s), Conductive copper strip (for flat metallic tape shielded cable)

  1. Prepare for Installation and Inspect Components

    Ensure all apparatus is de-energized before beginning installation. Inspect all components for damage, proper rating, and compatibility with mating parts. Confirm the package contents are complete and undamaged. Read the entire instructions before proceeding and gather all required tools. DANGER: All apparatus must be de-energized during installation or removal of part(s). Do not touch or move energized products in the work area. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment.

  2. Prepare the Cable and Slide Initial Components

    Wipe the outer jacket of the cable clean for a distance of 38 inches. Cut the cable end squarely to ensure maximum available length for crimp growth. If using an ECS grounding device, slide the ECS tube onto the cable a distance of 38 inches. Then, slide the receptacle housing onto the cable a distance of 30 inches.

  3. Perform Cable Specific Preparation

    Follow the specific cable preparation procedure based on your cable type. For Jacketed Concentric Neutral Cable (Part A), remove the cable jacket 13-3/4 inches from the end, bend neutral wires back, and remove the semi-con 10-1/4 inches from the end. For Flat Metallic Tape Shielded Cable with Semi-con Shield (Part B), remove the outer jacket 13-3/4 inches from the end, remove the tape shield 11-1/4 inches from the end, and remove the semi-con shield 10-1/4 inches from the end. In both cases, bevel the insulation end at a 45-degree angle approximately 1/4 inch back and thoroughly clean the insulation with an approved safety solvent, wiping from the cable end toward the outer jacket.

  4. Install Cable Adapter and Retaining Ring

    Apply supplied or ELASTIMOLD approved lubricant sparingly along the prepared cable and generously inside the cable adapter. Slide the adapter, small end first, over the cable with a twisting motion until its end is flush with the tape marker (if applicable). Remove any protruding cable insulation by cutting it even with the end of the cable adapter, ensuring not to cut or nick the adapter or conductor. The exposed conductor should measure 4 3/4 to 5 inches. Assemble the aluminum retaining ring over the conductor and snug it firmly against the cable adapter. Using the provided hex wrench, tighten the socket head screw hand tight. Confirm the exposed conductor now measures 4 3/8 to 4 3/4 inches.

  5. Crimp the Connector

    Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately fully insert it into the crimp connector, which contains inhibitor. Measure the distance from the end of the connector to the holding collar; it should be 6 3/4 to 7 inches. Confirm the bolt holes in the crimp connectors are positioned properly to align with the bolt holes of the mating part. Crimp the connectors following the instructions packaged with them, rotating each crimp 90 or 180 degrees. After crimping, re-measure the distance from the end of the connector to the holding collar, ensuring it is still 6 3/4 to 7 inches.

  6. Assemble and Torque Bolts

    Assemble the washers and bolt in the following order: flat washer against the spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten all bolts. Clean and lubricate the splice area. Using a torque wrench with a 15/16 inch socket, tighten all bolts to 50 to 60 ft. lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  7. Install Receptacle Housing and Vent

    Apply supplied or ELASTIMOLD approved lubricant generously to the outside of the cable adapter, the splice section, and the inside mating surface of the receptacle housing. Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the nylon venting rod (supplied). Use an assembly tool (650ATY or 600RRT) to slowly slide the receptacle housing completely over the splice section. Once fully seated, remove the venting rod. WARNING: If using the 600RRT tool, do not place your hand on the threaded rod or guide shaft with the assembly tool in place.

  8. Complete Grounding and Final Checks

    If an ECS grounding device is used, complete its installation according to its specific instructions. Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings, making a small loop and twisting tightly without damaging the eye. Connect this wire to ground. Check all cable adapters to ensure they are located properly and remove all vinyl tape markers. Remember to repeat steps 4 through 7 for any remaining cables to be joined.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.