ABB - Installation Products K656CY-L2360 - 15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

ABB Installation Products K656CY-L2360 15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable…

UPC: 075114107679


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656CY-L2360 is a 600 Series Deadbreak Separable Wye Joint Package designed for reliable 15-25 kV applications. This 3-way connector is engineered for robust performance in power distribution systems, featuring a 600 Ampere current rating. The package includes a test point for enhanced diagnostic capabilities and is constructed with a copper compression lug for secure conductor termination. It accommodates a wide range of cable insulation diameters, from 1.180 inches to 1.465 inches, ensuring broad compatibility. The K656CY-L2360 supports various conductor sizes, including compressed stranded AWG/kcmil up to 650, compacted solid up to 750, and mm² compact up to 400. This deadbreak wye joint is a critical component for ensuring safe and efficient power connections in medium-voltage networks. Its design prioritizes ease of installation and long-term operational integrity, making it a preferred choice for utility and industrial power infrastructure. The ABB K656CY-L2360 is manufactured by ABB - Installation Products, a trusted name in electrical components. Key specifications include: Voltage Rating: 15-25 kV, Current Rating: 600 A, Poles: 3-Way, Connection Type: Deadbreak, Series: 600 Series, Material: Copper, Cable Insulation Diameter Range: 1.180" - 1.465". This product is essential for creating secure and insulated connections in demanding electrical environments, providing a dependable solution for power system maintenance and expansion.
  • 15-25 kV voltage rating for medium-voltage applications
  • 600 Ampere current rating for robust power handling
  • 3-Way deadbreak separable wye joint configuration
  • Includes test point for diagnostic access
  • Accommodates cable insulation diameters from 1.180" to 1.465"

Specifications

Amperage Rating
600 A
Application
Compact Design is suitable for small vaults and manholes
Color
Black
Conductor Range
650 kcmil , 750 to 800 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions
Insulation
True
Length
37.27 in
Length
946.658 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible, 100 Percent Peroxide Cured EPDM Molded Rubber
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Separable Wye Joint
Voltage Rating
15 to 25 kV
Width
8.12 in
Width
206.248 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15/25kV 600 Series Deadbreak 3-Way L-Kit, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

K655L3-LM0360

15/25kV 600 Series Deadbreak 3-Way L-Kit, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K655YSR-L2330

600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K656I-F0250-SG3

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
Elbow, 600 Amp, Connector, Deadbreak, 15/25KV, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed / Stranded 500 or Compacted/Solid 600 or mmSquared Compact 250/300.

655LR-K0330

Elbow, 600 Amp, Connector, Deadbreak, 15/25KV, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed / Stranded 500 or Compacted/Solid 600 or mmSquared Compact 250/300.
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70.

K656I-H0250

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70.
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70. Cold-Shrinkable Jacket Seal Included.

K656CY-H0250-S

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70. Cold-Shrinkable Jacket Seal Included.
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K656I-M0380-SG3

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. Cold-Shrinkable Jacket Seal Included.

K656I-J0260-S

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. Cold-Shrinkable Jacket Seal Included.

Frequently Asked Questions

What is the voltage rating of the K656CY-L2360?

The K656CY-L2360 has a voltage rating of 15-25 kV.

What is the current rating for this wye joint package?

This ABB wye joint package is rated for 600 Amperes.

What is the compatible cable insulation diameter range?

The K656CY-L2360 is designed for cable insulation diameters between 1.180 inches and 1.465 inches.

What type of connection does the K656CY-L2360 offer?

The K656CY-L2360 provides a deadbreak separable wye joint connection.

Does this package include a test point?

Yes, the K656CY-L2360 3-way wye joint package includes a test point.

What is the manufacturer of the K656CY-L2360?

The K656CY-L2360 is manufactured by ABB - Installation Products.

What conductor sizes can be terminated with this connector?

It supports compressed stranded AWG/kcmil up to 650, compacted solid up to 750, and mm² compact up to 400.

How to Install K656/K676 Series Deadbreak Receptacles

This guide provides step-by-step instructions for the safe and proper installation of K656/K676 series deadbreak receptacles, including cable preparation, crimping, and final assembly for one cable leg.

Estimated time: 2h

Tools needed:

Hex wrench, Torque wrench with 15/16 inch socket, Wire brush (for aluminum cable), Assembly tool (650ATY or 600RRT), Rag, Approved safety solvent

Supplies needed:

Receptacle housings, Cable adapters, I, Wye or H Center sections, Aluminum holding collars, Lubricant (supplied or ELASTIMOLD approved), Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod, Crimp Chart, ECS grounding device (optional), HV insulated cap(s) or connector(s), No. 14 AWG copper wire (or equivalent), Tape (for markers and shield support), Conductive copper strip (for flat metallic tape shielded cable)

  1. Ensure Safety and Inspect Parts

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all parts for damage, rating, and compatibility with mating parts. If supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.

  2. Perform Pre-Installation Checks

    Check the contents of the package to ensure they are complete and undamaged. Verify all components for proper fit with the cable and/or mating products. Read the entire installation instructions before starting and have all required tools at hand. Maintain cleanliness throughout the procedure.

  3. Prepare Cable End

    Wipe the outer jacket clean for a distance of 38 inches (96.5 cm) from the end. Cut the cable end squarely to ensure maximum available length for crimp growth.

  4. Install ECS Grounding Device (Optional)

    If an ECS grounding device is being used, slide the tube onto the cable a distance of 38 inches (96.5 cm) from the end. Refer to the instructions included with the grounding device for specific details.

  5. Slide Receptacle Housing

    Slide the receptacle housing onto the cable a distance of 30 inches (76.2 cm) from the end.

  6. Prepare Jacketed Concentric Neutral Cable (Part A)

    From the cable end, measure 13-3/4 inches (34.9 cm) and remove the cable jacket with a straight, smooth cut, taking care not to damage neutral wires. Bend the neutral wires back and out of the way. From the cable end, measure 10-1/4 inches (26 cm) and remove the semi-con from the insulation with a straight, smooth, squared cut, taking care not to cut or nick the insulation. (Note: For Flat Metallic Tape Shielded Cable with Semi-con Shield, refer to Part B instructions in the document for different measurements and steps).

  7. Mark, Bevel, and Clean Insulation (Part A)

    At a point 1 inch (2.54 cm) from the end of the semi-con shield, wrap two turns of tape to serve as a marker. Bevel the end of the insulation at a 45-degree angle, approximately 1/4 inch (0.64 cm) back. Thoroughly clean the insulation to remove all traces of semi-conducting residue by wiping with a rag soaked with an approved safety solvent, always wiping from the end of the cable toward the outer jacket.

  8. Lubricate and Slide Cable Adapter (Part A)

    Apply supplied or ELASTIMOLD approved lubricant sparingly along the cable as shown in the documentation. Lubricate the inside of the cable adapter. Slide the adapter, small end first, over the cable with a twisting motion until the end of the adapter is flush with the tape marker.

  9. Remove Protruding Cable Insulation

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor should be 4-3/4 inches to 5 inches (12.07 cm to 12.7 cm). If not, redo the assembly.

  10. Assemble Aluminum Retaining Ring

    Assemble the aluminum retaining ring over the conductor and snug it firmly against the cable adapter. Using the hex wrench provided, tighten the socket head screw hand tight. Confirm the exposed conductor measures 4-3/8 inches to 4-3/4 inches (11.11 cm to 12.07 cm). If not, redo the assembly.

  11. Prepare and Insert Conductor into Crimp Connector

    Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it into the crimp connector, which contains inhibitor. Make sure the conductor is fully inserted into the crimp barrel. Measure the distance from the end of the connector to the holding collar. If the distance is over 7 inches (17.78 cm), do not proceed; recheck all previous work.

  12. Confirm Component Alignment

    Prior to crimping the connector, confirm that all components are positioned correctly as shown in the documentation. Crucially, confirm that the bolt holes in the crimp connectors are positioned properly to align with the bolt holes of the mating part.

  13. Crimp Connectors

    Crimp the connectors following the instructions packaged with the connectors. Rotate each crimp 90 or 180 degrees. After crimping, measure the distance from the end of the connector to the holding collar. If the distance is over 7 inches (17.78 cm), do not proceed; redo all previous work.

  14. Assemble Washers and Bolt

    Assemble the washers and bolt in the following order: flat washer against the spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten. The splice and cables are now in their final positions; do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  15. Torque Tighten Bolts

    Using a torque wrench with a 15/16 inch socket, tighten all bolts to 50 to 60 ft. lbs. (67.8 to 81.3 Nm).

  16. Apply Lubricant to Mating Surfaces

    Apply the supplied lubricant or ELASTIMOLD approved lubricant generously to the outside of the cable adapter, the area of the splice section as shown in the documentation, and the inside mating surface of the receptacle housing.

  17. Slide Receptacle Housing and Insert Venting Rod

    Slide the receptacle housing over the cable adapter and up to the edge of the interface (position shown in documentation). Insert the nylon venting rod (supplied).

  18. Use Assembly Tool to Complete Housing Slide

    Attach the appropriate assembly tool (650ATY or 600RRT) as shown in the documentation. Operate the tool to slowly slide the receptacle housing over the splice section. WARNING: DO NOT place hand on threaded rod or guide shaft with the assembly tool in place. Once the housing is in place, remove the venting rod.

  19. Perform Final Checks and Grounding

    Check all cable adapters to make sure they are located properly and remove all vinyl tape markers. Complete the installation of any ECS grounding device according to its instructions. Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings, making a small loop and twisting tightly, taking care not to damage the eye, and connect to ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.