ABB Installation Products K656CY-H2240 600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, Cable Insulation…
UPC: 783786477203
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 600 Amp current rating
- 15/25kV voltage class
- 3-Way separable Wye joint configuration
- Integrated test point for diagnostics
- Accommodates cable insulation diameters from 0.850" to 1.050"
- Copper compression lug for 1/0 AWG stranded / 2/0 AWG solid conductors (53.49 mm²)
Specifications
Amperage Rating | 600 A |
Application | Compact Design is suitable for small vaults and manholes |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Connection | Compression |
Connection Type | Compression Lug |
Current Rating | 600 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Length | 37.27 in |
Length | 946.658 mm |
Material | Copper |
Material | Housing - EPDM-Rubber |
Series | K656CY |
Size | Cable Insulation Diameter 0.850 inch to 1.050 inch |
Special Features | Fully Shielded, Fully Submersible, 100 Percent Peroxide Cured EPDM Molded Rubber |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Separable Wye Joint |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 15/25 kV |
Width | 8.12 in |
Width | 206.248 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 25.5000 L |
Package Weight (Metric) | 11.5670 kg |

161LRJS-D2240
200 Amp, 15kV, Loadbreak Elbow with Jacket Seal, Cable Insulation Diameter 0.890 inch to 1.220 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
K656CY-DP0594055
600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, L0300 - Cable Insulation Diameter 1.180 inch to 1.465 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 350 or Compacted/Solid 400. L0300 - Cable Insulation Diameter 1.180 inch to 1.465 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 350 or Compacted/Solid 400. H0230 - Cable Insulation Diameter 0.850 inch to 1.050 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded #1 or Compacted/Solid 1/0.
K656SRH0270
600 Amp Straight Receptacle with Cable Adapter, Lug and Retaining Ring, with capacitive testpoint, DeadBreak, 15/25KV, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid 250 or mmSquared 126.67.
K656SRH0320
600 Amp Straight Receptacle with Cable Adapter, Lug and Retaining Ring, with capacitive testpoint, DeadBreak, 15/25KV, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 or Compacted Solid 500/550.
K656I-LM0380
600 Amp, 15/25KV, Separable Straight Joint Package 2-Way with Test Point, Splice, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
K656I-H0270
25KV 600 Amp, Deadbreak, Separable Straight Joint Package (2-Way) with Test Point, Cable Insulation Diameter .850-1.050 inches, Aluminum Lug, Conductor Size 4/0 Stranded/Compressed AWG or 250 Solid/Compact kcmil. No Sealing kit.Frequently Asked Questions
How do I order the basic wye joint housing?
To order the basic wye joint housing only, specify K656CY-HP.
What is the primary use of the K656CY-HP joint?
The K656CY-HP is used to join cables in a disconnectable 3-way joint. It is suitable for small vaults, manholes, and direct-buried applications.
What are the 15kV operating voltage limits?
For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.
What are the 25kV operating voltage limits?
For the 25kV class, the maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase is 28kV.
What is the continuous current rating for this joint?
The K656CY-HP joint has a continuous current rating of 600 Amps for both 15kV and 25kV voltage classes.
What is the fault close rating for the joint?
The joint has a 25kA Symmetrical 10 Cycles Momentary & Fault Close rating for both 15kV and 25kV voltage classes.
What are the key design features of the K656CY-HP?
It is a compact, fully shielded, fully submersible 100% peroxide cured EPDM molded rubber connector. It also includes an integral capacitive test point.
Is the K656CY-HP joint submersible?
Yes, the K656CY-HP is a fully shielded, fully submersible 3-way disconnectable cable joint. It can also be used in direct-buried applications.
What industry standard does this product meet?
The K656CY-HP meets ANSI/IEEE Standard 386, Latest Revision.
What components are included in the K656CY-HP kit?
Each kit contains one 3-Way Bus Bar (K656CY-BUS), two Lubricant 82-08, one Installation Instruction IS-0388, and three Straight receptacles (K655YSR).
How to Install K656/K676 Series Deadbreak Receptacles
This guide provides detailed instructions for installing K656 and K676 series deadbreak receptacles, including cable preparation, crimping, and final assembly for splicing and tapping solid dielectric cables.
Estimated time: 2h
Tools needed:
Hex wrench, Torque wrench with 15/16 inch socket, Wire brush, Cable cutting tool, Wire strippers, Rag, Approved safety solvent, 650ATY assembly tool OR 600RRT assembly tool
Supplies needed:
Receptacle housings, Cable adapters, I, Wye or H Center sections (splice section), Aluminum holding collars, Lubricant (supplied or ELASTIMOLD approved), Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod, ECS grounding device (if used), No. 14 AWG copper wire (or equivalent), Tape (for markers, if applicable), Conductive copper strip (if applicable)
- De-energize and Inspect Apparatus
Ensure all apparatus in the work area are de-energized before beginning installation. Do not touch or move energized products. Inspect all components for damage, proper rating, and compatibility with mating parts. Failure to follow these safety instructions can result in serious injury or death.
- Prepare the Cable
Wipe the outer jacket clean for 38 inches and cut the cable end squarely. Refer to the 'Special Cable Preparation Supplement' (Part A for Jacketed Concentric Neutral Cable or Part B for Flat Metallic Tape Shielded Cable) included with these instructions. Follow the specific procedure for your cable type to remove the jacket, semi-con shield, and bevel the insulation. Thoroughly clean the insulation to remove all semi-conducting residue.
- Install Receptacle Housing and Cable Adapter
If using an ECS grounding device, slide the tube onto the cable 38 inches. Slide the receptacle housing onto the cable 30 inches. Apply lubricant sparingly along the cable and inside the cable adapter. Slide the adapter, small end first, over the cable with a twisting motion until it is flush with the tape marker (if used during cable prep). Remove any protruding cable insulation, ensuring the exposed conductor measures 4 3/4 to 5 inches. Assemble the aluminum retaining ring over the conductor, snug it against the cable adapter, and hand tighten the socket head screw with the hex wrench. Confirm the exposed conductor now measures 4 3/8 to 4 3/4 inches.
- Install and Crimp Connectors
Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it fully into the crimp connector, which contains inhibitor. Confirm the bolt holes in the crimp connectors are positioned to align with the mating part. Crimp the connectors according to their instructions, rotating each crimp 90 or 180 degrees. After crimping, measure the distance from the end of the connector to the holding collar; it must be 6 3/4 to 7 inches maximum. Repeat this step for all remaining cables.
- Assemble and Torque Bolts
Assemble the washers and bolt in the following order: flat washer against the spade contact, Belleville washer (concave side down), and then the hex-head bolt. Hand tighten the bolt. Using a torque wrench with a 15/16 inch socket, tighten all bolts to 50 to 60 ft. lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.
- Lubricate and Final Housing Assembly
Generously apply the supplied or ELASTIMOLD approved lubricant to the outside of the cable adapter, the splice section, and the inside mating surface of the receptacle housing. Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the nylon venting rod. Use either the 650ATY or 600RRT assembly tool to slowly slide the receptacle housing over the splice section. WARNING: If using the 600RRT tool, DO NOT place your hand on the threaded rod or guide shaft. Once the housing is in place, remove the venting rod. Repeat for all remaining cables.
- Complete Grounding
Check all cable adapters to ensure they are properly located and remove any vinyl tape markers. If an ECS grounding device is used, complete its installation per its instructions. Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings, making a small loop and twisting tightly without damaging the eye. Connect this wire to ground.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.