Authorized ABB Distributor (Installation Products)
ABB - Installation Products K655YSR-K0280 - 600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.

ABB Installation Products K655YSR-K0280 600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter…

UPC: 783786358823


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 600 Series Deadbreak Straight Receptacle, SKU K655YSR-K0280, is engineered for robust electrical connections in medium-voltage applications. This receptacle is rated for 600 Amps and operates within a voltage range of 15-25 kV, making it suitable for demanding utility and industrial power distribution systems. Designed to accommodate cable insulation diameters from 1.090 inches to 1.310 inches, it ensures a secure and reliable interface for a variety of cable sizes. The integrated aluminum compression lug provides a durable and high-conductivity connection point. This receptacle is compatible with conductor sizes ranging from 250 kcmil for compressed stranded conductors to 300 kcmil for compacted solid conductors, offering flexibility in system design. Manufactured by ABB Installation Products, this 600 Series receptacle exemplifies precision engineering for critical power infrastructure. Its deadbreak design ensures safety during connection and disconnection procedures by isolating energized conductors. The aluminum construction of the compression lug guarantees excellent electrical performance and resistance to corrosion, contributing to the longevity of the connection. This product is a key component for ensuring the integrity and reliability of medium-voltage power systems, facilitating efficient power transfer and maintenance operations. The specific dimensions and material choices are optimized for performance and ease of installation in challenging environments. Trust ABB Installation Products for dependable solutions in electrical power connectivity.
  • 600 Amp current rating for high-capacity power distribution.
  • 15-25 kV voltage rating for medium-voltage applications.
  • Accommodates cable insulation diameters from 1.090" to 1.310".
  • Aluminum compression lug for secure and conductive connections.
  • Suitable for 250 kcmil compressed stranded or 300 kcmil compacted solid conductors.

Specifications

Amperage Rating
600 A
Application
These Connectors allow a straight cable connection on Switchgear or Electrical Apparatus equipped with 600 Amp Bushings
Color
Black
Conductor Range
250 kcmil , 300 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions
Insulation
True
Length
16.98 in
Length
431.292 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible, Can be easily Connected or Disconnected in a De-Energized State
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 250 or Compacted Solid 300.

755LRTP-L0280-DRG

600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 250 or Compacted Solid 300.
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. 2 X (Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. )

K656I-P0410-P0410

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. 2 X (Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. )
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.

K656CY-G0240

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

K656I-K0270

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K656CY-L0330

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size kcmil Compressed Stranded 300 or Solid 350 or mmSquared 150

K655YSR-J2290

600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size kcmil Compressed Stranded 300 or Solid 350 or mmSquared 150
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70.

K656I-J0250

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70.
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 550.

K656CY-K0320

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 550.

Frequently Asked Questions

What is the voltage rating of this ABB deadbreak receptacle?

The ABB 600 Series Deadbreak Straight Receptacle has a voltage rating of 15-25 kV.

What is the maximum current this receptacle can handle?

This receptacle is rated for a maximum current of 600 Amps.

What cable insulation diameters are compatible with this receptacle?

The receptacle is designed for cable insulation diameters ranging from 1.090 inches to 1.310 inches.

What type of lug is used for connection?

This receptacle features an aluminum compression lug for connection.

What conductor sizes can be used with this receptacle?

It can be used with 250 kcmil compressed stranded or 300 kcmil compacted solid conductors.

How to Install K656/K676 Series Deadbreak Receptacles

This guide provides detailed instructions for installing K656 and K676 series deadbreak receptacles, including cable preparation, crimping, and final assembly for splicing and tapping solid dielectric cables.

Estimated time: 2h

Tools needed:

Hex wrench, Torque wrench with 15/16 inch socket, Wire brush, Cable cutting tool, Wire strippers, Rag, Approved safety solvent, 650ATY assembly tool OR 600RRT assembly tool

Supplies needed:

Receptacle housings, Cable adapters, I, Wye or H Center sections (splice section), Aluminum holding collars, Lubricant (supplied or ELASTIMOLD approved), Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod, ECS grounding device (if used), No. 14 AWG copper wire (or equivalent), Tape (for markers, if applicable), Conductive copper strip (if applicable)

  1. De-energize and Inspect Apparatus

    Ensure all apparatus in the work area are de-energized before beginning installation. Do not touch or move energized products. Inspect all components for damage, proper rating, and compatibility with mating parts. Failure to follow these safety instructions can result in serious injury or death.

  2. Prepare the Cable

    Wipe the outer jacket clean for 38 inches and cut the cable end squarely. Refer to the 'Special Cable Preparation Supplement' (Part A for Jacketed Concentric Neutral Cable or Part B for Flat Metallic Tape Shielded Cable) included with these instructions. Follow the specific procedure for your cable type to remove the jacket, semi-con shield, and bevel the insulation. Thoroughly clean the insulation to remove all semi-conducting residue.

  3. Install Receptacle Housing and Cable Adapter

    If using an ECS grounding device, slide the tube onto the cable 38 inches. Slide the receptacle housing onto the cable 30 inches. Apply lubricant sparingly along the cable and inside the cable adapter. Slide the adapter, small end first, over the cable with a twisting motion until it is flush with the tape marker (if used during cable prep). Remove any protruding cable insulation, ensuring the exposed conductor measures 4 3/4 to 5 inches. Assemble the aluminum retaining ring over the conductor, snug it against the cable adapter, and hand tighten the socket head screw with the hex wrench. Confirm the exposed conductor now measures 4 3/8 to 4 3/4 inches.

  4. Install and Crimp Connectors

    Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it fully into the crimp connector, which contains inhibitor. Confirm the bolt holes in the crimp connectors are positioned to align with the mating part. Crimp the connectors according to their instructions, rotating each crimp 90 or 180 degrees. After crimping, measure the distance from the end of the connector to the holding collar; it must be 6 3/4 to 7 inches maximum. Repeat this step for all remaining cables.

  5. Assemble and Torque Bolts

    Assemble the washers and bolt in the following order: flat washer against the spade contact, Belleville washer (concave side down), and then the hex-head bolt. Hand tighten the bolt. Using a torque wrench with a 15/16 inch socket, tighten all bolts to 50 to 60 ft. lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  6. Lubricate and Final Housing Assembly

    Generously apply the supplied or ELASTIMOLD approved lubricant to the outside of the cable adapter, the splice section, and the inside mating surface of the receptacle housing. Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the nylon venting rod. Use either the 650ATY or 600RRT assembly tool to slowly slide the receptacle housing over the splice section. WARNING: If using the 600RRT tool, DO NOT place your hand on the threaded rod or guide shaft. Once the housing is in place, remove the venting rod. Repeat for all remaining cables.

  7. Complete Grounding

    Check all cable adapters to ensure they are properly located and remove any vinyl tape markers. If an ECS grounding device is used, complete its installation per its instructions. Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings, making a small loop and twisting tightly without damaging the eye. Connect this wire to ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.