Authorized ABB Distributor (Installation Products)
ABB - Installation Products K656CY-L0330 - 15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

ABB Installation Products K656CY-L0330 15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable…

UPC: 783786383177


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 600 Series 15-25kV 3-Way Deadbreak Separable Wye Joint Package (SKU: K656CY-L0330) is a deadbreak connector designed for 15-25kV medium-voltage applications. This 3-way wye joint package includes a test point for safe voltage verification without de-energizing the system. The package accommodates cable insulation diameters from 1.180 inch to 1.465 inch, making it suitable for a range of conductor sizes including AWG/kcmil 500 compressed stranded, 600 compacted solid, and mm² 250/300 compacted conductors. The deadbreak design ensures safe, reliable connections in underground distribution systems, switchgear, and pad-mounted transformers. The aluminum compression lug provides a secure, corrosion-resistant termination for stranded or solid conductors. The test point allows for non-intrusive voltage detection, reducing downtime during maintenance or troubleshooting. This package is part of ABB's Installation Products catalog, a trusted brand in electrical infrastructure solutions. Use this wye joint package in underground residential distribution (URD), commercial power systems, and industrial facilities where reliable, separable connections are required. The 600 Series is designed for compatibility with industry-standard separable connectors and meets medium-voltage distribution requirements.
  • 15-25kV medium-voltage rating for underground distribution
  • 3-way wye joint package with deadbreak design for safe, separable connections
  • Test point included for non-intrusive voltage verification
  • Accommodates cable insulation diameters 1.180" to 1.465"
  • Aluminum compression lug for stranded or solid conductors (AWG/kcmil 500/600, mm² 250/300)

Specifications

Amperage Rating
600 A
Application
Compact Design is suitable for small vaults and manholes
Color
Black
Conductor Range
500 kcmil , 600 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions
Insulation
True
Length
37.27 in
Length
946.658 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible, 100 Percent Peroxide Cured EPDM Molded Rubber
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Separable Wye Joint
Voltage Rating
15 to 25 kV
Width
8.12 in
Width
206.248 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
26.2000 L
Package Weight (Metric)
11.8840 kg
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

K655LR-J0330

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size kcmil Compressed Stranded 300 or Solid 350 or mmSquared 150

K655YSR-J2290

600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size kcmil Compressed Stranded 300 or Solid 350 or mmSquared 150
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70.

K656I-J0250

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70.
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 550.

K656CY-K0320

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 550.
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550. Cold Shrinkable Seal with Copper Rod and Crimp Connector Included.

K656CY-K0320-SG1

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550. Cold Shrinkable Seal with Copper Rod and Crimp Connector Included.
600 Amp, 15/25kV, Separable H Joint Kit, 4-Way with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.

K656CH-HO240

600 Amp, 15/25kV, Separable H Joint Kit, 4-Way with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.
600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

K656CH-H0270

600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
600 Amp, 15/25KV, Separable Wye Joint package, 3-Way with Test Point, 2 X ( Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550. ) and 1 X ( Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. ) Cold Shrinkable Seal with Copper Rod and Crimp Connector Included.

K656CY-DP0592440

600 Amp, 15/25KV, Separable Wye Joint package, 3-Way with Test Point, 2 X ( Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550. ) and 1 X ( Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. ) Cold Shrinkable Seal with Copper Rod and Crimp Connector Included.

Frequently Asked Questions

Is the K656CY-HP modular for future system changes?

Yes, the K656CY-HP is modular, ideal for accommodating future system circuit changes or expansions. It can also be used initially as a 3-way joint with insulated caps on unused interfaces.

What are the operating voltages for the 15kV class?

For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV and maximum phase-to-phase is 14.4kV.

Can the K656CY-HP be used in direct-buried applications?

Yes, the K656CY-HP separable wye joint can be used in direct-buried applications.

What is the K656CY-HP used for?

The K656CY-HP cable joint is used to join cables in a disconnectable 3-way joint. It is suitable for small vaults, manholes, and direct-buried applications.

What are the operating voltages for the 25kV class?

For the 25kV class, the maximum phase-to-ground operating voltage is 16.2kV and maximum phase-to-phase is 28kV.

What is the continuous current rating of the joint?

The continuous current rating for both 15kV and 25kV voltage classes is 600 Amps.

Is the K656CY-HP fully submersible?

Yes, the K656CY-HP is fully shielded and fully submersible, made of 100% peroxide cured EPDM molded rubber.

Does the K656CY-HP include a test point?

Yes, the K656CY-HP includes an integral capacitive test point.

What type of connector is the K656CY-HP?

It is a 15/25kV, 600A Deadbreak rated separable connector.

What items are included in the K656CY-HP kit?

Each kit contains one 3-Way Bus Bar, two units of Lubricant 82-08, one Installation Instruction IS-0388, and three Straight receptacles.

How to Install K656/K676 Series Deadbreak Receptacles

This guide provides step-by-step instructions for the installation and wiring of K656CY, K676CY, K656CH, K676CH, K656I, and K676I Deadbreak Receptacles, including cable preparation and grounding procedures for 15kV and 25kV applications.

Tools needed:

Hex wrench, Torque wrench with 15/16” socket, Wire brush, Crimp tool, 650ATY assembly tool OR 600RRT assembly tool, Rag, Approved safety solvent

Supplies needed:

Receptacle housings, Cable adapters, I, Wye or H Center sections, Aluminum holding collars, Lubricant, Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod, Tape, Conductive copper strip, No. 14 AWG copper wire or equivalent

  1. Ensure Safety and Inspect Components

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Inspect all parts for damage, rating, and compatibility with mating parts. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.

  2. Prepare the Cable End

    Wipe the outer jacket clean for a distance of 38 inches (96.5 cm) from the end. Cut the cable end squarely to ensure maximum available length for crimp growth, making sure the cut is square with respect to the interface.

  3. Slide Receptacle Housing and Grounding Device

    If an ECS grounding device is being used, slide its tube onto the cable a distance of 38 inches (96.5 cm). Then, slide the receptacle housing onto the cable a distance of 30 inches (76.2 cm).

  4. Perform Cable Preparation

    Prepare the cable according to its type. For Jacketed Concentric Neutral Cable: Remove jacket (13-3/4"), bend neutrals, remove semi-con (10-1/4"), mark with tape (1" from semi-con), bevel insulation (1/4" at 45 degrees), clean insulation, lubricate, and slide adapter flush with tape marker. For Flat Metallic Tape Shielded Cable: Remove outer jacket (13-3/4"), remove tape shield (11-1/4"), wrap conductive copper strip and tape marker, remove semi-con shield (10-1/4"), bevel insulation (1/4" at 45 degrees), clean insulation, lubricate, and slide adapter flush with tape marker.

  5. Prepare Conductor and Secure Retaining Ring

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter, taking care not to cut or nick the cable adapter or conductor. The exposed conductor should measure 4 3/4” – 5”. Assemble the aluminum retaining ring over the conductor and snug it firmly against the cable adapter. Using the provided hex wrench, tighten the socket head screw hand tight. Confirm the exposed conductor measures 4 3/8” to 4 3/4”.

  6. Insert Conductor into Crimp Connector

    Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it fully into the crimp connector, which contains inhibitor. Measure the distance from the end of the connector to the holding collar; it must not exceed 7 inches (17.78 cm). Repeat steps 5 through 8 for any remaining cables to be joined.

  7. Crimp Connectors

    Prior to crimping, confirm components are positioned correctly and that the bolt holes in the crimp connectors align with the bolt holes of the mating part. Crimp the connectors following the instructions packaged with them, rotating each crimp 90 or 180 degrees. After crimping, measure the distance from the end of the connector to the holding collar; it must not exceed 7 inches (17.78 cm).

  8. Assemble and Torque Bolts

    Assemble the washers and bolt in the following order: flat washer against the spade contact, Belleville washer (concave side down), and then the hex-head bolt. Hand tighten all bolts. Using a torque wrench with a 15/16” socket, tighten all bolts to 50 to 60 ft. lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  9. Lubricate and Position Receptacle Housing

    Apply the supplied lubricant or an ELASTIMOLD approved lubricant generously to the outside of the cable adapter, the area of the splice section, and the inside mating surface of the receptacle housing. Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the nylon venting rod (supplied).

  10. Seat Receptacle Housing Using Assembly Tool

    Attach either the 650ATY or 600RRT assembly tool. For 650ATY, ensure the “U” shaped yoke is over the splice section and the “C” shaped yoke is over the receptacle housing, then slowly raise the handle to slide the receptacle housing over the splice section. For 600RRT, slide the receptacle housing over the interface by turning the hex nut. Remove the venting rod. Repeat steps 9 through 10 for any remaining cables.

  11. Complete Grounding and Final Checks

    Check all cable adapters to ensure they are located properly and remove all vinyl tape markers. If using an ECS grounding device, complete its installation according to its instructions. Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings, making a small loop and twisting tightly without damaging the eye, then route to ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.