ABB Installation Products K656CY-DP0594897 15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, (2)…
UPC: 783786615742
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15-25kV rated for medium-voltage applications
- 3-way deadbreak separable joint with test point for safe voltage verification
- Includes (2) K0270 lugs for 1.090-1.310 inch insulation diameter (4/0 to 250 mm² conductors)
- Includes (1) M0320 lug for 1.370-1.630 inch insulation diameter (450 to 550 mm² conductors)
- Aluminum compression lugs for reliable, long-term connections
Specifications
Amperage Rating | 600 A |
Application | Compact Design is suitable for small vaults and manholes |
Color | Black |
Conductor Range | 4/0 STR/COMPR AWG , 250 kcmil , 450 kcmil , 500 to 550 kcmil |
Connection | Compression |
Connection Type | Deadbreak Separable |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Length | 37.27 in |
Length | 946.658 mm |
Material | Aluminum |
Material | Housing - EPDM-Rubber |
Poles | 3-Way |
Series | 600 Series |
Size | Cable Insulation Diameter 1.090 inch to 1.310 inch (K0270), 1.370 inch to 1.630 inch (M0320) |
Special Features | Fully Shielded, Fully Submersible, 100 Percent Peroxide Cured EPDM Molded Rubber |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Separable Wye Joint |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 15-25kV |
Width | 8.12 in |
Width | 206.248 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

756LR-M0300-S
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold-Shrinkable Jacket Seal Included.
K656CY-DP0580918
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, (2) K0320 - Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 or Compacted Solid 500/550. (1) G0250 - Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Compacted Solid 3/0. SG1 - Cold Shrinkable Seal with Copper Rod and Crimp Connector Included. K656CY-K0320-K0320-G0250-SG1
168RLR-G5270
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Solid 250 kcmil.
656ETP-N0420
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 1250.
K655CCP-N0410
15/25kV, 600 Amp, no test point, Combo T Connecting Plug with Stud, Cable Adapter and Lug Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
K656CY-N0410-SG3
600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 1000. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
252LRJS-B5220
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, with Jacket Seal, Cable Insulation Diameter - .635 to .905 inch. Bi-Metal Lug, Conductor Size 220 - #2 Stranded/Compressed or #1 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.Frequently Asked Questions
Can the K656CY-HP be used in direct-buried applications?
Yes, the K656CY can also be used in direct-buried applications.
What is the impulse withstand rating for 25kV?
For the 25kV voltage class, the BIL impulse withstand rating is 140kV (1.2 x 50 microsecond wave).
What items are included in the K656CY-HP kit?
Each kit contains one 3-Way Bus Bar (K656CY-BUS), two lubricants (82-08), one installation instruction (IS-0388), and three straight receptacles (K655YSR).
Are the components of the K656CY-HP reusable?
Yes, the K656CY-HP features reusable components, which can help reduce inventory and other costs.
Does the K656CY-HP have a test point?
Yes, the K656CY-HP includes an integral capacitive test point.
Is the K656CY-HP submersible?
Yes, the K656CY-HP is fully shielded and fully submersible, made from 100% peroxide cured EPDM molded rubber.
Does the K656CY-HP meet any industry standards?
Yes, the K656CY-HP meets ANSI/IEEE Standard 386, Latest Revision.
What is the impulse withstand rating for 15kV?
For the 15kV voltage class, the BIL impulse withstand rating is 95kV (1.2 x 50 microsecond wave).
What are the operating voltages for the 25kV class?
For the 25kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV and the maximum phase-to-phase is 28kV.
What are the operating voltages for the 15kV class?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and the maximum phase-to-phase is 14.4kV.
How to Install K656/K676 Series Deadbreak Receptacles
This guide provides comprehensive instructions for the safe installation and assembly of K656 and K676 series deadbreak receptacles, including detailed cable preparation, crimping, and final grounding procedures for splicing and tapping solid dielectric cables. A complete installation requires repeating instructions for each cable leg (two for 'I', three for 'Y', and four for 'H' connectors).
Estimated time: 2h 30m
Tools needed:
Cable cutting tool, Wire strippers, Hex wrench, Wire brush (for aluminum cable), Crimp tool, Torque wrench with 15/16 inch socket, Rag, Approved safety solvent, 650ATY Assembly Tool OR 600RRT Assembly Tool
Supplies needed:
Receptacle housings, Cable adapters, I, Wye or H Center sections, Aluminum holding collars, Lubricant (supplied or ELASTIMOLD approved), Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod, Tape (for markers), Conductive copper strip (for flat metallic tape shielded cable, if applicable), No. 14 AWG copper wire (or equivalent), ECS grounding device (if used)
- Ensure Safety and Inspect Components
DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products in the work area. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all parts for damage, correct rating, and compatibility with mating parts. Check package contents to ensure completeness and proper fit with cable and/or mating products. Have all required tools at hand and maintain cleanliness throughout the procedure.
- Prepare the Cable for Initial Assembly
Wipe the outer jacket clean for a distance of 38 inches and cut the cable end squarely to ensure maximum available length for crimp growth. If an ECS grounding device is being used, slide the tube onto the cable a distance of 38 inches. Slide the receptacle housing onto the cable a distance of 30 inches.
- Perform Detailed Cable Preparation According to Cable Type
Refer to the specific cable preparation supplement (Part A for Jacketed Concentric Neutral Cable or Part B for Flat Metallic Tape Shielded Cable with Semi-con Shield) included with these instructions. Carefully follow the procedure for your cable type, which includes removing the outer jacket, semi-con shield, beveling insulation, cleaning, and lubricating the cable before sliding on the cable adapter until it is flush with the tape marker. Ensure all measurements are precise to avoid redoing the assembly.
- Prepare Conductor and Crimp Connector
Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of exposed conductor should be 4-3/4 to 5 inches; otherwise, redo assembly. Assemble the aluminum retaining ring over the conductor and snug it firmly against the cable adapter. Using the provided hex wrench, tighten the socket head screw hand tight. Confirm the exposed conductor now measures 4-3/8 to 4-3/4 inches; otherwise, redo assembly. Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it fully into the crimp connector (which contains inhibitor). Confirm the distance from the end of the connector to the holding collar is 6-3/4 to 7 inches maximum. Crimp the connectors following the instructions packaged with them, rotating each crimp 90 or 180 degrees. After crimping, re-measure the distance from the end of the connector to the holding collar, ensuring it is 6-3/4 to 7 inches maximum; otherwise, redo all previous work.
- Assemble and Torque Bolts
Assemble the washers and hex-head bolt in the following order: flat washer against spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten. The splice and cables are now in their final positions; do not attempt to move or reposition any part of the assembly after the bolts are tightened. Using a torque wrench with a 15/16 inch socket, tighten all bolts to 50 to 60 ft. lbs.
- Lubricate and Complete Receptacle Housing Assembly
Apply supplied lubricant or ELASTIMOLD approved lubricant generously to the outside of the cable adapter, the area of the splice section, and the inside mating surface of the receptacle housing. Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the nylon venting rod (supplied). Using either the 650ATY or 600RRT assembly tool, slowly slide the receptacle housing over the splice section until fully seated. Remove the venting rod. WARNING: If using the 600RRT tool, do not place hands on the threaded rod or guide shaft with the assembly tool in place.
- Perform Final Checks and Grounding
Check all cable adapters to make sure they are properly located and remove all vinyl tape markers. If using an ECS grounding device, complete its installation according to the instructions included with the device. Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings. Make a small loop and twist tightly, taking care not to damage the eye, and connect this wire to ground.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.