ABB - Installation Products K655CCP-N0410 - 15/25kV, 600 Amp, no test point, Combo T Connecting Plug with Stud, Cable Adapter and Lug Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

ABB Installation Products K655CCP-N0410 15/25kV, 600 Amp, no test point, Combo T Connecting Plug with Stud, Cable Adapter and…

UPC: 783786357086


Documents & Media
BrochureInstallation InstructionsManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655CCP-N0410 is a robust 15/25 kV, 600 Amp Combo T Connecting Plug designed for reliable electrical connections in demanding industrial applications. This specific model features a stud connection, integrated cable adapter, and an aluminum compression lug kit, ensuring a secure and efficient termination for conductors up to 1000 kcmil compressed stranded aluminum. Engineered by ABB Installation Products, this component is built to handle significant electrical loads and environmental stresses. The K655CCP-N0410 is suitable for cable insulation diameters ranging from 1.515 inches to 1.780 inches, providing a precise fit for a variety of medium-voltage cable types. Its design prioritizes ease of installation and long-term performance, making it a critical element in power distribution systems. The absence of a test point on this configuration simplifies the assembly while maintaining essential connectivity functions. The aluminum compression lug ensures excellent conductivity and mechanical strength, crucial for maintaining system integrity under continuous operation. This connecting plug is an integral part of the ABB Installation Products portfolio, known for its quality and dependability in electrical infrastructure projects. When specifying components for medium-voltage systems, the K655CCP-N0410 offers a direct and effective solution for connecting cables to equipment, ensuring power is delivered safely and efficiently. Its specifications are tailored for applications requiring high current carrying capacity and reliable insulation performance within the 15/25 kV range. The included cable adapter and lug kit streamline the installation process, reducing labor time and potential for error. Choose the K655CCP-N0410 for your next project requiring a dependable 600 Amp, 15/25 kV connecting plug with a stud and aluminum compression lug.
  • 15/25 kV Voltage Rating
  • 600 Amp Current Rating
  • Combo T Connecting Plug with Stud
  • Includes Cable Adapter and Aluminum Compression Lug Kit
  • Suitable for Cable Insulation Diameter: 1.515" - 1.780"

Specifications

Amperage Rating
600 A
Color
Black
Conductor Range
1000 kcmil
Connection
Compression
Insulation
True
Material
Housing - EPDM-Rubber
Special Features
The hollow bore of the ComboT allows visual validation that the compression lug is positioned properly before the snuffer/bus is inserted and tightened
Standard
ANSI/IEEE Standard 386
Type
ComboT Connecting Plug
Voltage Rating
15 to 25 kV
Width
10 in
Width
254 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, with 3 X ( Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. )

K656CYP0410P0410P041

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, with 3 X ( Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. )
600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 1000. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.

K656CY-N0410-SG3

600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 1000. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, with Jacket Seal, Cable Insulation Diameter - .635 to .905 inch. Bi-Metal Lug, Conductor Size 220 - #2 Stranded/Compressed or #1 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.

252LRJS-B5220

25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, with Jacket Seal, Cable Insulation Diameter - .635 to .905 inch. Bi-Metal Lug, Conductor Size 220 - #2 Stranded/Compressed or #1 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 3 AWG Stranded/Compressed, 2 AWG Solid/Compact. no Sealing Kit. Housing Fuse Size and Voltage Code 1 - 3-45 Amps, 8.3kV and 6-20 Amps, 15.5kV.

168FLR1-B5210

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 3 AWG Stranded/Compressed, 2 AWG Solid/Compact. no Sealing Kit. Housing Fuse Size and Voltage Code 1 - 3-45 Amps, 8.3kV and 6-20 Amps, 15.5kV.
15/25 kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.09-1.31 inches (27.48-33.27 mm), Bi-Metal Lug, Conductor Size 270 - 4/0 Stranded/Compressed, 250 kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.

252LR-E5270

15/25 kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.09-1.31 inches (27.48-33.27 mm), Bi-Metal Lug, Conductor Size 270 - 4/0 Stranded/Compressed, 250 kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
28kV, 200 Amps, Loadbreak Elbow Connector with Test Point, No Sealing Kit, .805 inch - 1.060 Inch Cable Insulation Diameter, 1/0 Stranded, 2/0 Solid Wire Size, Copper Compression Lug. Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installation Instructions.

262LR-C2240

28kV, 200 Amps, Loadbreak Elbow Connector with Test Point, No Sealing Kit, .805 inch - 1.060 Inch Cable Insulation Diameter, 1/0 Stranded, 2/0 Solid Wire Size, Copper Compression Lug. Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installation Instructions.
28kV, 200 Amps, Loadbreak Elbow Connector with Test Point, No Sealing Kit, .805 inch - 1.060 Inch Cable Insulation Diameter, 3/0 Stranded, 4/0 Solid Wire Size, Copper Compression Lug. Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installation Instructions.

262LR-C2260

28kV, 200 Amps, Loadbreak Elbow Connector with Test Point, No Sealing Kit, .805 inch - 1.060 Inch Cable Insulation Diameter, 3/0 Stranded, 4/0 Solid Wire Size, Copper Compression Lug. Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installation Instructions.
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70. Cold-Shrinkable Jacket Seal Included.

K656I-H0250-S

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70. Cold-Shrinkable Jacket Seal Included.

Frequently Asked Questions

What is the maximum conductor size for this connecting plug?

The K655CCP-N0410 is designed for compressed stranded aluminum conductors up to 1000 kcmil.

What is the specified cable insulation diameter range?

This connecting plug is suitable for cable insulation diameters ranging from 1.515 inches to 1.780 inches.

What type of lug is included with this kit?

The kit includes an aluminum compression lug for secure conductor termination.

Does this connecting plug have a test point?

No, this specific model (K655CCP-N0410) does not feature a test point.

What is the current rating of the ABB K655CCP-N0410?

The ABB K655CCP-N0410 has a current rating of 600 Amps.

What is the voltage rating for this ABB connecting plug?

The voltage rating for the K655CCP-N0410 is 15/25 kV.

How to Install K655/K656CCP Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of K655/K656CCP Deadbreak Elbow Connectors on 15kV or 25kV class systems, including cable preparation, lug crimping, and connection to mating apparatus.

Estimated time: 2h

Tools needed:

Crimping tool, Wire brush (for aluminum conductors), 600 ATM assembly tool, Hotstick (for K656CCP voltage test), Suitable sensing device (for K656CCP voltage test)

Supplies needed:

Lubricant (supplied), Vinyl plastic tape (if applicable), Tape retainer (if applicable), Tape marker (if applicable), Wire (at least No. 14 AWG Copper), Suitable ground connector, Silicone grease (for K656CCP test point cap), Compression Lug (supplied), Cable Adapter (supplied), Elbow (supplied), Stud (supplied)

  1. Prepare for Installation and Safety Check

    Review the contents of the package to ensure all parts are complete and undamaged. Inspect all components for proper fit with the cable and/or mating products. Ensure all apparatus are de-energized during installation or removal of parts to prevent serious or fatal injury. Have all required tools at hand and maintain cleanliness throughout the procedure.

  2. Position and Cut Cable

    Position the cable in its final assembled location, allowing enough slack for adequate clearance to remove the elbows. For concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.

  3. Clean Cable Outer Surface

    Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent-back concentric neutral wires.

  4. Prepare Cable Jacket and Shield

    Follow the instructions that apply to your specific cable type for removing the outer jacket and preparing the shield. This may involve removing the outer jacket to 12-3/4 inches (324mm), folding back shield wires, removing flat metallic tape shield and securing with vinyl plastic tape, or removing fabric/corrugated shields and installing tape retainers/markers. For UNISHIELD* or lead sheath cables, refer to the 10TL cable shield adapter instructions.

  5. Prepare Semi-Con Shield and Cable Insulation

    Remove the semi-con shield to the dimensions shown (9-3/4 inches or 248mm, and 10-3/4 inches or 273mm), ensuring not to cut or nick the cable insulation. Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back.

  6. Clean, Lubricate, and Install Cable Adapter

    Thoroughly clean and then lubricate the cable insulation, always working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  7. Trim Insulation and Verify Conductor Length

    Remove any protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor should be 4-3/8 inches to 4-11/16 inches (111mm-119mm). If the length is incorrect, redo the assembly.

  8. Prepare Conductor and Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping (it should be less than 6-1/2 inches or 165mm). Crimp the compression lug following the crimping instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping should be 6-1/2 inches to 7-1/4 inches (165mm-184mm); otherwise, redo the assembly.

  9. Lubricate and Install Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter is still flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.

  10. Prepare Mating Products

    DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from the elbow and the mating part. Install the stud in the mating part. Clean and lubricate both the elbow and the mating part with the lubricant supplied, ensuring surfaces remain clean.

  11. Connect Elbow to Mating Part

    Push the elbow onto the mating part. Using the 600 ATM assembly tool, thread the connector into the mating part until it bottoms. Apply 50 to 60 foot-pounds of torque.

  12. Ground the Connector and Cable Shield

    Insert one end of a wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded according to the instructions supplied with any grounding device, or through an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  13. Install Additional Mating Connectors (Optional)

    If applicable, clean and lubricate the entire male interface and either a DR(G), GLR, or LR connector of the appropriate voltage class with the supplied or ELASTIMOLD® approved lubricant. Install the DR(G), GLR, or LR to the bushing interface following the instructions supplied with those specific products.

  14. Perform Voltage Test (K656CCP Only)

    For K656CCP connectors, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the meter used. Test with a suitable sensing device designed for capacitive test points to determine if the cable is energized. Contamination, moisture, or incorrect equipment can give a false 'no voltage' indication; treat the elbow as energized until confirmed by other means. After testing, clean, lubricate the inside surface of the cap with silicone grease, and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.