ABB - Installation Products K656CH-J0300 - 600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.

ABB Installation Products K656CH-J0300 600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation…

UPC: 783786336708


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB Installation Products K656CH-J0300 is a 4-way separable H joint package designed for 15/25 kV applications, rated for 600 Amps. It features an integrated test point for diagnostic capabilities. The joint is engineered to accommodate cable insulation diameters ranging from 0.980 inches to 1.180 inches. It utilizes an aluminum compression lug for secure and reliable electrical connections. The package supports various conductor sizes, including compressed stranded 350 kcmil, compacted solid 400 kcmil, and mm² compact 185. This product is suitable for medium voltage power distribution systems where reliable cable terminations are essential. The H joint configuration allows for branching of power cables, and the inclusion of a test point facilitates in-service testing and troubleshooting without disrupting the main power flow. ABB's commitment to quality in their Installation Products ensures dependable performance in electrical infrastructure. SKU: K656CH-J0300. UNSPSC: 39121421.
  • 600 Amp, 15/25 kV rating for medium voltage applications
  • 4-Way separable H joint configuration for cable branching
  • Integrated test point for diagnostic and troubleshooting access
  • Accommodates cable insulation diameters from 0.980" to 1.180"
  • Aluminum compression lug for secure conductor termination

Specifications

Amperage Rating
600 A
Application
Compact Design is suitable for small vaults and manholes
Color
Black
Conductor Range
350 kcmil , 400 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions
Insulation
True
Length
37.27 in
Length
946.658 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible, 100 Percent Peroxide Cured EPDM Molded Rubber. Includes Integral Capacitive Test Point. Reusable Components Reduce Inventory and other Costs
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Separable H-Joint Assembly
Voltage Rating
15 to 25 kV
Width
8.12 in
Width
206.248 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
30.0000 L
Package Weight (Metric)
13.6080 kg
600 Amp, DeadBreak Elbow Connector, 2-Way L Kit, 35KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold-Shrinkable Jacket Seal Included.

755L2-M0300-S

600 Amp, DeadBreak Elbow Connector, 2-Way L Kit, 35KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold-Shrinkable Jacket Seal Included.
600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 350 or Solid 400 or mmSquared 185.

K655YSR-K0300

600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 350 or Solid 400 or mmSquared 185.
600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, K0320 - Cable Insulation Diameter 1.090 inch to 1.310 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 450 or Compacted/Solid 550. SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring. K0320 - Cable Insulation Diameter 1.090 inch to 1.310 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 450 or Compacted/Solid 550. SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring. G0240 - Cable Insulation Diameter 0.760 inch to 0.950 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 1/0 or Compacted/Solid 2/0. S - Cold Shrinkable Jacket Seal.

K656CY-DP0591166

600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, K0320 - Cable Insulation Diameter 1.090 inch to 1.310 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 450 or Compacted/Solid 550. SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring. K0320 - Cable Insulation Diameter 1.090 inch to 1.310 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 450 or Compacted/Solid 550. SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring. G0240 - Cable Insulation Diameter 0.760 inch to 0.950 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 1/0 or Compacted/Solid 2/0. S - Cold Shrinkable Jacket Seal.
600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size kcmil Compressed Stranded 650 or Solid 750 or mmSquared 400.

K655YSR-L2360

600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size kcmil Compressed Stranded 650 or Solid 750 or mmSquared 400.
600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K656CH-N0380

600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.

K656CH-J0320

600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.
600 Amp, 15/25KV, Separable H Joint package 4-Way with Test Point, N0360 - Cable Insulation Diameter 1.515 inch to 1.780 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 650 or Compacted/Solid 750. N0360 - Cable Insulation Diameter 1.515 inch to 1.780 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 650 or Compacted/Solid 750. K0360 - Cable Insulation Diameter 1.090 inch to 1.310 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 650 or Compacted/Solid 750. K0260 - Cable Insulation Diameter 1.090 inch to 1.310 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 3/0 or Compacted/Solid 4/0.

K656CH-DP0593508

600 Amp, 15/25KV, Separable H Joint package 4-Way with Test Point, N0360 - Cable Insulation Diameter 1.515 inch to 1.780 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 650 or Compacted/Solid 750. N0360 - Cable Insulation Diameter 1.515 inch to 1.780 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 650 or Compacted/Solid 750. K0360 - Cable Insulation Diameter 1.090 inch to 1.310 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 650 or Compacted/Solid 750. K0260 - Cable Insulation Diameter 1.090 inch to 1.310 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 3/0 or Compacted/Solid 4/0.
600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

K656CH-H0250

600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

Frequently Asked Questions

What standard does the K656CH joint meet?

The K656CH joint meets ANSI/IEEE Standard 386, Latest Revision.

How do I select the correct compression lug code?

Choose the proper compression lug code from the XXX Code table based on the conductor size (AWG or kcmil) and material (Universal Aluminum or All Copper).

How do I select the correct cable insulation diameter code?

Measure the cable insulation diameter in inches or mm, then select the insulation letter code from the W table that best straddles this diameter.

What components are included in a complete joint package?

A complete joint package includes an insulated bus bar, straight receptacle housing, retaining rings, cable size adapters, lugs, bolts, and washers.

Is the K656CH joint suitable for submersible applications?

Yes, the K656CH joint is fully shielded and fully submersible, made from 100% peroxide cured EPDM molded rubber.

What is the continuous current rating for the joint?

The K656CH joint has a continuous current rating of 600 Amps for both 15kV and 25kV voltage classes.

What are the 25kV class operating voltage ratings?

For the 25kV class, the maximum phase-to-ground operating voltage is 16.2kV and maximum phase-to-phase is 28kV. It has a 140kV BIL impulse withstand.

What are the 15kV class operating voltage ratings?

For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV and maximum phase-to-phase is 14.4kV. It has a 95kV BIL impulse withstand.

What is the K656CH separable "H" joint used for?

The K656CH separable "H" joint is used to join cables in a disconnectable 4-way joint. It is suitable for small vaults and manholes due to its compact size.

What standard does the K656CH joint meet?

The K656CH joint meets ANSI/IEEE Standard 386, Latest Revision.

How to Install K656CH Deadbreak Receptacles

This guide provides step-by-step instructions for the safe and proper installation of K656CH deadbreak receptacles, including cable preparation, crimping, and final assembly for high voltage applications.

Estimated time: 2h

Tools needed:

Hex wrench, Torque wrench with 15/16 inch socket, Wire brush (for aluminum cable), 650ATY assembly tool OR 600RRT assembly tool, Rag, Approved safety solvent, Cable preparation tools (e.g., strippers, beveling tool)

Supplies needed:

Receptacle housings, Cable adapters, Center section (I, Wye, or H), Aluminum holding collars, Lubricant (supplied), Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod, No. 14 AWG copper wire, Tape (for markers), Conductive copper strip (if applicable), ECS grounding device (or other grounding kit)

  1. Perform Initial Safety Checks and Part Inspection

    Ensure all apparatus is de-energized before starting installation. Inspect all parts for damage, verify ratings, and confirm compatibility with mating components. Failure to follow safety instructions can result in serious injury or death. This product must be installed by competent personnel trained in high voltage electrical equipment.

  2. Prepare Cable Outer Jacket

    Wipe the outer jacket clean for a distance of 38 inches (96.5 cm) from the end. Cut the cable end squarely to ensure maximum available length for crimp growth.

  3. Install Optional Grounding Device Tube and Receptacle Housing

    If using an ECS grounding device, slide the ECS tube onto the cable for a distance of 38 inches (96.5 cm). Then, slide the receptacle housing onto the cable for a distance of 30 inches (76.2 cm).

  4. Prepare Cable Insulation and Shield

    Refer to the special cable preparation supplement for your specific cable type (Jacketed Concentric Neutral or Flat Metallic Tape Shielded). Remove the outer jacket, neutral wires (if applicable), and semi-con shield to the specified lengths. Bevel the end of the insulation at a 45-degree angle, approximately 1/4 inch (0.6 cm) back. Thoroughly clean the insulation with an approved safety solvent, wiping from the cable end toward the outer jacket.

  5. Lubricate Cable and Install Cable Adapter

    Apply the supplied lubricant sparingly along the prepared cable insulation. Lubricate the inside of the cable adapter. Slide the adapter, small end first, over the cable with a twisting motion until the end of the adapter is flush with the tape marker you created during cable preparation.

  6. Trim Insulation and Install Retaining Ring

    Remove any protruding cable insulation by cutting it even with the end of the cable adapter, taking care not to nick the adapter or conductor. The exposed conductor should measure 4 3/4 to 5 inches (12.1 to 12.7 cm). Assemble the aluminum retaining ring over the conductor and snug it firmly against the cable adapter. Using the provided hex wrench, tighten the socket head screw hand tight. Confirm the exposed conductor now measures 4 3/8 to 4 3/4 inches (11.1 to 12.1 cm).

  7. Prepare and Insert Conductor into Crimp Connector

    Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor immediately before fully inserting it into the crimp connector, which contains inhibitor. Measure the distance from the end of the connector to the holding collar; if it is over 7 inches (17.8 cm), do not proceed and redo all previous work.

  8. Crimp Connectors

    Crimp the connectors following the instructions packaged with the connectors. Rotate each crimp 90 or 180 degrees as specified. After crimping, measure the distance from the end of the connector to the holding collar; if it is over 7 inches (17.8 cm), do not proceed and redo all previous work.

  9. Assemble Washers and Bolt

    Assemble the washers and bolt in the following order: place the flat washer against the spade contact, then the Belleville washer with its concave side down, followed by the hex-head bolt. Hand tighten the bolt. The splice and cables are now in their final positions; do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  10. Torque Bolts

    Using a torque wrench with a 15/16 inch socket, tighten all bolts to 50 to 60 ft. lbs. (67.8 to 81.3 Nm).

  11. Lubricate and Position Receptacle Housing

    Apply the supplied lubricant generously to the outside of the cable adapter, the area of the splice section, and the inside mating surface of the receptacle housing. Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the nylon venting rod (supplied).

  12. Complete Receptacle Housing Assembly

    Attach either the 650ATY or 600RRT assembly tool as shown in its specific instructions. Slowly operate the assembly tool to slide the receptacle housing over the splice section until fully seated. WARNING: If using the 600RRT tool, DO NOT place hands on the threaded rod or guide shaft while the tool is in place. Remove the venting rod once assembly is complete.

  13. Perform Final Checks and Grounding

    Check all cable adapters to ensure they are located properly and remove all vinyl tape markers. Complete the installation of any ECS grounding device according to its instructions. Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings, making a small loop and twisting tightly without damaging the eye, then connect to ground.

  14. Repeat for Additional Cables (If Applicable)

    If installing a multi-way splice (e.g., 'I', 'Y', or 'H' connector), repeat steps 2 through 13 for each additional cable required for the complete installation.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.