ABB Installation Products K656CH-H0250 600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation…
UPC: 783786427970
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 600 Amp continuous current rating with 25kA symmetrical momentary rating
- 4-way separable joint design for easy assembly, disassembly, and future expansions
- Built-in capacitive test point for safe voltage testing without de-energizing circuits
- Fully shielded, fully submersible construction with 100% peroxide-cured EPDM rubber
- Suitable for 2/0 AWG stranded, 3/0 AWG solid, or 67.43 mm² conductors
Specifications
Amperage Rating | 600 A |
Application | Compact Design is suitable for small vaults and manholes |
Color | Black |
Conductor Range | 2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG |
Connection | Compression |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Length | 37.27 in |
Length | 946.658 mm |
Material | Housing - EPDM-Rubber |
Special Features | Fully Shielded, Fully Submersible, 100 Percent Peroxide Cured EPDM Molded Rubber. Includes Integral Capacitive Test Point. Reusable Components Reduce Inventory and other Costs |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Separable H-Joint Assembly |
Voltage Rating | 15 to 25 kV |
Width | 8.12 in |
Width | 206.248 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 30.0000 L |
Package Weight (Metric) | 13.6080 kg |

168FLR3B0250
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.
K655YSR-J0320
600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 or Solid 500/550.
K655YSR-K0330
600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Solid 600 or mmSquared 250/300.
K151-SR-C2240
Straight Receptacle, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49.
K655YSR-H0250
600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Solid 3/0 or mmSquared 67.43.
K152SR-B0240-150TB6
Straight Receptacle with Test Point, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. With 150TB6 Bail.
K152SR-A0250
Straight Receptacle with Test Point, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
655LR-F0220
Elbow, 600 Amp, Deadbreak, 15/25KV, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.Frequently Asked Questions
What is the maximum operating voltage for 25kV class?
For the 25kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase is 28kV.
What is the maximum operating voltage for 15kV class?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.
What is the continuous current rating?
The continuous current rating for both 15kV and 25kV voltage classes is 600 Amps.
What is the momentary current rating?
The momentary current rating for both 15kV and 25kV voltage classes is 25kA Symmetrical for 10 cycles.
What is the momentary current rating?
The momentary current rating for both 15kV and 25kV voltage classes is 25kA Symmetrical for 10 cycles.
What is the continuous current rating?
The continuous current rating for both 15kV and 25kV voltage classes is 600 Amps.
What is the maximum operating voltage for 25kV class?
For the 25kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase is 28kV.
What is the maximum operating voltage for 15kV class?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.
What is the maximum operating voltage for 15kV class?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.
What is the continuous current rating?
The continuous current rating for both 15kV and 25kV voltage classes is 600 Amps.
How to Install K656CH Deadbreak Receptacles
This guide provides detailed instructions for the safe and proper installation of K656CH, K656CY, and K656I Deadbreak Receptacles, covering cable preparation, conductor crimping, component assembly, and grounding procedures for high voltage electrical equipment.
Estimated time: 2h
Tools needed:
Hex wrench, Torque wrench (with 15/16 inch socket), Crimp tool, Wire strippers, Rag, Approved safety solvent, 650ATY Assembly Tool OR 600RRT Assembly Tool, Wire brush (if using aluminum cable), Multimeter
Supplies needed:
K656CH Receptacle housings, Cable adapters, I, Wye, or H Center section, Aluminum holding collars, Lubricant (supplied or ELASTIMOLD approved), Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod (supplied), No. 14 AWG copper wire (or equivalent, for grounding), Tape (for markers), Conductive copper strip (for flat metallic tape shielded cable), ECS grounding device (if used)
- De-energize and Inspect Components
DANGER: Ensure all apparatus is de-energized before beginning installation or removal of any parts. Do not touch or move energized products. Inspect all supplied components for damage, correct rating, and compatibility with mating parts. Check package contents for completeness. Read the entire installation instructions before starting.
- Prepare Cable Outer Jacket and Slide Initial Components
Wipe the outer jacket of the cable clean for a distance of 38 inches (96.5 cm). Cut the cable end squarely to ensure maximum available length for crimp growth. If using an ECS grounding device, slide the ECS tube onto the cable for a distance of 38 inches (96.5 cm). Slide the receptacle housing onto the cable for a distance of 30 inches (76.2 cm).
- Prepare Cable Insulation and Shield (Type-Specific)
Refer to the special cable preparation supplement provided with these instructions and follow the procedure specific to your cable type. For Jacketed Concentric Neutral Cable: Remove the cable jacket 13-3/4 inches (34.9 cm) from the end, bend neutral wires back, and remove the semi-con shield 10-1/4 inches (26 cm) from the end. For Flat Metallic Tape Shielded Cable: Remove the outer jacket 13-3/4 inches (34.9 cm) from the end, remove the tape shield 11-1/4 inches (28.6 cm) from the end, wrap a conductive copper strip, and remove the semi-con shield 10-1/4 inches (26 cm) from the end. In both cases, bevel the insulation end at a 45-degree angle (approx. 1/4 inch back), thoroughly clean the insulation with an approved safety solvent, and apply lubricant sparingly before sliding the cable adapter over the cable until it is flush with the tape marker.
- Prepare Conductor and Assemble Retaining Ring
Remove any protruding cable insulation by cutting it even with the end of the cable adapter, taking care not to cut or nick the cable adapter or the conductor. The exposed conductor length should be 4-3/4 to 5 inches (12.1 to 12.7 cm). Assemble the aluminum retaining ring over the conductor and snug it firmly against the cable adapter. Using the provided hex wrench, tighten the socket head screw hand tight. Confirm the exposed conductor now measures 4-3/8 to 4-3/4 inches (11.1 to 12.1 cm). If measurements are incorrect, redo the assembly.
- Install and Crimp Connectors
Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor immediately before fully inserting it into the crimp connector, which contains inhibitor. Measure the distance from the end of the connector to the holding collar; it must be 6-3/4 to 7 inches (17.1 to 17.8 cm). If over 7 inches, redo all previous work. Crimp the connectors following the instructions packaged with them, rotating each crimp 90 or 180 degrees. After crimping, re-measure the distance from the end of the connector to the holding collar; it must still be 6-3/4 to 7 inches (17.1 to 17.8 cm). Repeat steps 4 and 5 for all remaining cables to be joined.
- Assemble Washers and Bolt
Confirm components are positioned correctly and bolt holes in the crimp connectors align with the bolt holes of the mating part. Assemble the washers and bolt in the following order: flat washer against the spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten the bolt. Clean and lubricate the splice section as shown in the diagram.
- Torque Bolts
Using a torque wrench with a 15/16 inch socket, tighten all hex-head bolts to 50 to 60 ft. lbs. The splice and cables are now in their final positions; do not attempt to move or reposition any part of the assembly after the bolts are tightened.
- Lubricate and Position Receptacle Housing
Apply the supplied lubricant or an ELASTIMOLD approved lubricant generously to the outside of the cable adapter, the lubricated area of the splice section, and the inside mating surface of the receptacle housing. Slide the receptacle housing over the cable adapter and up to the edge of the interface (as shown in the diagram). Insert the supplied nylon venting rod.
- Complete Housing Assembly with Tool
Attach either the 650ATY or 600RRT assembly tool as shown in the instructions. With the assembly tool in place, slowly operate it to slide the receptacle housing completely over the splice section. WARNING: DO NOT place hands on the threaded rod or guide shaft when using the 600RRT assembly tool. Once the housing is fully seated, remove the venting rod. Repeat steps 8 and 9 for any remaining cables.
- Final Checks and Grounding
Check all cable adapters to ensure they are located properly and remove all vinyl tape markers. Complete the installation of any ECS grounding device according to its specific instructions. Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings, forming a small loop and twisting tightly, taking care not to damage the eye. Connect this wire to a suitable ground.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.