ABB - Installation Products K656CETPN0410 - 15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

ABB Installation Products K656CETPN0410 15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug…

UPC: 075114114639


Documents & Media
BrochureInstallation InstructionsManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656CETPN0410 Combo T Elbow Reducing Tap Plug Kit is a high-current, medium-voltage connector designed for 15/25kV, 600 Amp systems. This kit includes a base aluminum elbow connector with an integrated test point, a reducing tap plug with stud, a cable adapter, three 1000 kcmil aluminum compression lugs, and an insulated cap kit. The system supports cable insulation diameters ranging from 1.515" to 1.780" (38.5 to 45.2 mm), making it suitable for compressed stranded conductors from 250 kcmil to 1000 kcmil. The combo T elbow enables safe, loadbreak tap connections while maintaining system integrity and electrical continuity. The integrated test point allows for voltage verification without de-energizing the system, enhancing operational safety and maintenance efficiency. The aluminum construction ensures corrosion resistance, mechanical strength, and long-term reliability in harsh industrial environments. Applications include utility substations, industrial power distribution systems, renewable energy installations, commercial facilities, and critical infrastructure projects requiring high-current, medium-voltage connectivity. The kit is part of ABB’s Installation Products line, known for robust engineering and compatibility with standard medium-voltage cable systems. Key components include the K656BCETP elbow connector housing, 650SA stud, 03700XXX series compression lugs, 655CA-W cable adapter, lubricant tube, installation instructions (IS-1216), and crimp chart (CC-0050). The kit is designed for quick installation and reliable performance in high-demand electrical systems.
  • 15/25kV rated, 600 Amp capacity for medium-voltage systems
  • Supports cable insulation diameters from 1.515" to 1.780" (38.5-45.2 mm)
  • Includes test point for safe voltage verification without de-energization
  • Aluminum construction for corrosion resistance and mechanical durability
  • Compatible with compressed stranded conductors from 250 to 1000 kcmil

Specifications

Amperage Rating
600 A
Application
600 Amps, 25kV Connector
Color
Black
Conductor Range
1000 kcmil
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Special Features
Reducing Tap Plug with Stud, Cable Adapter, and Lug. Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
ComboT Elbow with Test Point
Voltage Rating
25 kV
Width
13.31 in
Width
338.074 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, with 3 X ( Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. )

K656CYP0410P0410P041

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, with 3 X ( Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. )
600 Amp, 15/25kV, Basic Combo T Elbow Reducing Tap Plug with Stud, with Test Point

K656BCETP

600 Amp, 15/25kV, Basic Combo T Elbow Reducing Tap Plug with Stud, with Test Point
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

655CETP-J0270

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
15/25kV, 600 Amp, no test point, Combo T Elbow Reducing Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

K655CETP-N0410

15/25kV, 600 Amp, no test point, Combo T Elbow Reducing Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

655CETPH0270DRG

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.

655CETPF0260DRG

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Shrink-Fit Jacket Seal Kit.

655CETPL0330DRGS

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Shrink-Fit Jacket Seal Kit.
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

655CETP-K0330-DRG

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

Frequently Asked Questions

How much does the ComboT reduce stack height?

Each combination elbow/connecting plug reduces stack height by 2.67 inches.

What tools are needed for ComboT installation?

The ComboT installs with standard assembly tools and uses a standard 600 or 900 series stud.

How does the 25 kV reducing tap prevent flashover?

The 25 kV reducing tap includes vents to prevent partial-vacuum flashover.

What are the voltage ratings for CETP connectors?

CETP connectors are available in 15 kV and 25 kV voltage classes. The maximum phase-to-ground operating voltage is 8.3 kV for 15 kV and 15.2 kV for 25 kV.

What is the continuous current rating for CETP connectors?

CETP connectors have continuous current ratings of 600 A for deadbreak and 200 A for loadbreak, or 900 A for deadbreak and 200 A for loadbreak.

What is the loadbreak switching current for CETP?

The loadmake/loadbreak switching current for CETP connectors is 200 A.

What are the voltage ratings for CCP/CBW connectors?

CCP/CBW connectors have a voltage class of 15/25/28 kV. The maximum phase-to-ground operating voltage is 16.2 kV.

What is the continuous current rating for CCP/CBW?

CCP/CBW connectors have continuous current ratings of 600 A or 900 A.

What stud size is used for ComboT assembly?

ComboT assembly utilizes a standard 5/8 inch–11 stud that threads into the equipment bushing.

What is a critical safety step before ComboT installation?

The system must be de-energized before initiating any ComboT installation. Always refer to the complete instruction sheet.

How to Install K656CETPN0410 Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 655/656/675/676CETP Deadbreak Elbow Connectors, including cable preparation, lug crimping, and connection to mating apparatus.

Estimated time: 2h

Tools needed:

Cable preparation tools, Crimping tool, Wire brush (for aluminum conductor), 600AT assembly tool (for products dated Sep 30, 2013 or earlier), 600ATM assembly tool (for products dated Oct 1, 2013 or later), Hotstick, Suitable sensing device for capacitive test points

Supplies needed:

Lubricant (supplied), Vinyl plastic tape, Tape retainer (if fabric tape shield), Tape marker (if applicable), Compression Lug (supplied), Cable Adapter (supplied), Elbow (supplied), Wire with ampacity at least equivalent to No. 14 AWG Copper, Suitable connector for grounding wire, Silicone grease

  1. De-energize Apparatus and Position Cable

    DANGER: All apparatus must be de-energized during installation or removal of part(s). Position the cable in its final assembled location with enough slack. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product.

  2. Clean Cable and Prepare Outer Jacket/Shield

    Clean the outer surface of the cable for 24” (610mm). Remove the outer jacket to the specified dimension. Fold back shield wires. Remove any flat metallic tape, fabric tape, longitudinally corrugated, or semi-con shields as per instructions, installing tape retainers and markers where required. Do not cut or nick cable insulation.

  3. Bevel Insulation and Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean, then lubricate (lubricant supplied) the cable insulation, working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare Conductor Length

    Cut the protruding cable insulation even with the end of the cable adapter. Ensure the exposed conductor length is 4 3/8”–4 11/16” (111mm–119mm). Do not cut or nick the cable adapter or conductor. If the length is incorrect, redo the assembly.

  5. Crimp Compression Lug

    For copper conductor, fully insert the conductor into the compression lug. For aluminum conductor, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping (must be less than 6 1/2” (165mm)). Crimp the lug according to its supplied instructions. Wipe off all excess inhibitor. Verify the distance from the end of the compression lug to the cable adapter is 6 1/2”–7 1/4” (165mm–184mm) after crimping. If incorrect, redo the assembly.

  6. Lubricate and Install Elbow

    Lubricate (lubricant supplied) the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.

  7. Prepare Mating Parts and Install Stud

    WARNING: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from the elbow and the mating part. Install the stud into the apparatus by hand until fully seated. Clean and lubricate (lubricant supplied) both the elbow and the mating part, keeping surfaces clean.

  8. Connect Elbow to Mating Part

    Push the elbow onto the mating part. Use the appropriate assembly tool (600AT for products dated Sep 30, 2013 or earlier, or 600ATM for products dated Oct 1, 2013 or later) to engage the hex broach in the contact assembly. Insert the contact assembly into the elbow interface to engage the stud. Torque the contact assembly until the torque limiter on the 600AT ratchets (19 to 25 foot/pounds) or tighten to 50/60 foot/pounds with the 600ATM (DO NOT EXCEED 60 FOOT POUNDS TORQUE).

  9. Ground the Cable Shield

    Insert one end of a piece of wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, without damaging the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded according to the instructions supplied with the grounding device, or through an alternate method if no device is used. It is also recommended that the cable jacket be waterproofed at this point.

  10. Install Loadbreak Interface (Optional)

    Clean and lubricate (lubricant supplied) the entire loadbreak interface and any mating DR(G), ESA, GLR, or LR components of the appropriate voltage class. Install these components to the tap plug interface following their specific instructions.

  11. Verify Seating Indication

    Confirm complete assembly of an insulated cap or elbow by ensuring no portion of the colored interface sleeve is visible when viewed from the side.

  12. Perform Voltage Test (656CETP only)

    WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. If using the integral capacitance test point on a 656CETP, remove the test point cap with a hotstick, peeling it off at an angle. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized, following the meter's manufacturer directions. Contamination or incorrect equipment can provide a false 'no voltage' indication; treat the elbow as energized until confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.