ABB - Installation Products K655SR-L-0330 - 600 Amp, Straight Receptacle with Cable Adapter, Lug and Retaining Ring, DeadBreak, 15/25 KV, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.

ABB Installation Products K655SR-L-0330 600 Amp, Straight Receptacle with Cable Adapter, Lug and Retaining Ring, DeadBreak…

UPC: 783786434336


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655SR-L-0330 is a 600 Amp, straight receptacle designed for medium-voltage applications up to 15/25 kV. It features a deadbreak design for safe, load-break operations without interrupting service. The unit includes an aluminum compression lug compatible with 500 kcmil compressed stranded or 600 kcmil compacted solid conductors, as well as 250/300 mm² compact conductors. Cable insulation diameter range is 1.180 inch to 1.465 inch, ensuring compatibility with a wide range of medium-voltage cables. The retaining ring secures the cable adapter, while the lug provides a reliable termination point for high-current applications. This receptacle is ideal for industrial power distribution, substations, and renewable energy systems where reliable, high-amperage connections are critical. The deadbreak design eliminates the need for de-energizing the system during installation or maintenance, reducing downtime and improving operational efficiency. The K655SR-L-0330 is a straight receptacle with a cable adapter, lug, and retaining ring. The aluminum compression lug is specifically designed for high-current applications. The conductor size compatibility includes compressed stranded 500 kcmil, compacted solid 600 kcmil, and compact 250/300 mm² conductors. The deadbreak functionality ensures safe operation within the 15/25 kV voltage class.
  • 600 Amp rated straight receptacle for medium-voltage applications up to 15/25 kV
  • Deadbreak design enables safe load-break operations without service interruption
  • Aluminum compression lug compatible with 500/600 kcmil compressed stranded or 250/300 mm² compact conductors
  • Cable insulation diameter range: 1.180 inch to 1.465 inch
  • Includes cable adapter, lug, and retaining ring for secure termination

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amps
Color
Black
Conductor Range
500 kcmil , 600 kcmil
Connection
Compression
Connection Type
Deadbreak
Current Rating
600 A
Environmental Conditions
All Weather Conditions, Fully Submersible
Insulation
True
Length
16.98 in
Length
431.292 mm
Material
Aluminum Compression Lug
Material
Housing - EPDM-Rubber
Series
K655SR
Size
Cable Insulation Diameter 1.180 inch to 1.465 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

K655LR-J0330

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
600 Amp Straight Receptacle with Cable Adapter, Lug and Retaining Ring, with capacitive testpoint, DeadBreak, 15/25KV, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid Compact 250 or mmSquared 126.67.

K656SR-H2270

600 Amp Straight Receptacle with Cable Adapter, Lug and Retaining Ring, with capacitive testpoint, DeadBreak, 15/25KV, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid Compact 250 or mmSquared 126.67.
600 Amp Straight Receptacle with Cable Adapter, Lug and Retaining Ring, with capacitive testpoint, DeadBreak, 15/25KV, Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG Compressed Stranded #2 or Solid Compact #1 or mmSquared 33.62. Aluminum Compression Lug.

K656SR-F0220

600 Amp Straight Receptacle with Cable Adapter, Lug and Retaining Ring, with capacitive testpoint, DeadBreak, 15/25KV, Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG Compressed Stranded #2 or Solid Compact #1 or mmSquared 33.62. Aluminum Compression Lug.
600 Amp Straight Receptacle with Cable Adapter, Lug and Retaining Ring, with capacitive testpoint, DeadBreak, 15/25KV, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid Compact 250 or mmSquared 126.67.

K656SR-H5270

600 Amp Straight Receptacle with Cable Adapter, Lug and Retaining Ring, with capacitive testpoint, DeadBreak, 15/25KV, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid Compact 250 or mmSquared 126.67.
600 Amp, Straight Receptacle with Cable Adapter, Lug and Retaining Ring, DeadBreak, 15/25 KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.

K655SR-J0330

600 Amp, Straight Receptacle with Cable Adapter, Lug and Retaining Ring, DeadBreak, 15/25 KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.
600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.

K656SR-L0330

600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.
15/25kV, Direct Test Elbow, DeadBreak, 600 Amp, Cable Insulation 1.180-1.465 inches, Aluminum Compression Lug, Conductor Size 750 Stranded/Compressed or 900 Solid/Compact.

K656DLR-L0380

15/25kV, Direct Test Elbow, DeadBreak, 600 Amp, Cable Insulation 1.180-1.465 inches, Aluminum Compression Lug, Conductor Size 750 Stranded/Compressed or 900 Solid/Compact.
25kv Straight Receptacle 600 Amp With Sealing Kit, Capacitive Test Points. Cable Insulation Diameter 1.180-1.465 Inches, Aluminum Lug, Conductor Size 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact.

K656SR-L0330-S

25kv Straight Receptacle 600 Amp With Sealing Kit, Capacitive Test Points. Cable Insulation Diameter 1.180-1.465 Inches, Aluminum Lug, Conductor Size 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact.

Frequently Asked Questions

What is the maximum operating voltage for this receptacle?

The receptacle is rated for 15/25 kV medium-voltage applications.

What is the cable insulation diameter range?

The receptacle accommodates cable insulation diameters from 1.180 inch to 1.465 inch.

Is a retaining ring included with this receptacle?

Yes, the receptacle includes a retaining ring to secure the cable adapter.

What conductor sizes are compatible with this receptacle?

The aluminum compression lug supports 500 or 600 kcmil compressed stranded conductors, or 250/300 mm² compact solid conductors.

What material is the lug made of?

The compression lug is made of aluminum for reliable conductivity and corrosion resistance.

Does this receptacle support load-break operations?

Yes, the deadbreak design allows safe load-break operations without interrupting service.

How to Install the K655SR/M655SR Deadbreak Straight Receptacle

This guide provides step-by-step instructions for the safe and proper installation of the K655SR and M655SR deadbreak straight receptacles, enabling an in-line cable connection to a standard ANSI-386 600 amp 15kV, 25kV, or 35kV bushing.

Estimated time: 1h 30m

Tools needed:

5/8-11 tap, Hex wrench, Torque wrench with 15/16 socket, Wire brush (for aluminum cable), Wire strippers, Suitable connector tool (for neutral wires), Hose clamp (for 35kV only)

Supplies needed:

Receptacle housing, Bushing adapter, Cable adapter, Aluminum holding collar, Hex head bolt, Crimp connector, Belleville washer, Flat washer, Nylon venting rod, Lubricants (supplied or ELASTIMOLD approved), Brass bolt, Bushing converter contact, Loctite, Tape marker, No. 14 AWG copper wire (or equivalent), Hose Clamp (M655SR for 35kV only)

  1. De-energize and Inspect Apparatus

    Ensure all apparatus is de-energized during installation or removal of parts. Do not touch or move energized products in the work area. Inspect all parts for damage, rating, and compatibility with mating parts. Failure to follow these instructions will result in damage to the product and serious or fatal injury. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment.

  2. Prepare Apparatus Bushing

    If a stud is present in the apparatus bushing, remove the stud and re-tap the hole using a 5/8-11 tap. Clean and lubricate the apparatus bushing and bushing converter interface. Assemble the bushing converter onto the apparatus bushing. Apply 3-4 drops of Loctite to the threads of the brass bolt. Assemble the contact adapter to the apparatus bushing, with the bolt hole facing out, using a 5/8” brass bolt. Torque the brass bolt to 60 ft.-lbs.

  3. Prepare Cable End

    Train the cable end and straighten it into its final position. Cut the cable squarely to ensure maximum available length for crimp growth.

  4. Manage Concentric Neutral Wires

    If applicable, unwrap the concentric neutral wires a distance of 30” (76cm). Do not cut these wires; instead, bend and fold them back out of the way.

  5. Clean Outer Jacket and Slide Receptacle Housing

    Wipe the outer jacket of the cable clean for a distance of 38” (96.5cm) or up to the concentric neutral wires. Slide the receptacle housing onto the cable a distance of 30” (76cm).

  6. Prepare Semi-Con Shield

    Remove the semi-con shield and install a tape marker to the dimensions shown in the documentation (10-1/4” (26.04cm) and 11-1/4” (28.58cm)). Exercise caution to avoid cutting or nicking the cable insulation.

  7. Install Cable Adapter

    Bevel the end of the cable insulation at a 45˚ angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  8. Expose Conductor and Secure Holding Collar

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. Verify that the length of the exposed conductor is 4 3/4” – 5” (12.06cm – 12.7cm); if not, redo the assembly. Position the holding collar over the conductor and flush against the cable adapter. Using the supplied hex wrench, tighten the setscrew.

  9. Prepare and Position Crimp Connector

    Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it into the crimp connector, which contains inhibitor. Ensure the conductor is fully inserted into the crimp barrel. Measure the distance from the end of the connector to the holding collar; if this distance is over 7” (17.8cm), do not proceed and redo all previous work.

  10. Confirm Component Alignment

    Confirm that the receptacle housing, cable adapter, crimp connector, and contact adapter are oriented in the correct order. Crucially, confirm that the bolt hole in the crimp connector is aligned with the bolt hole in the contact adapter.

  11. Crimp Connector

    Crimp the connectors following the instructions packaged with the connectors. Rotate each crimp 90˚. After crimping, measure the distance from the end of the connector to the holding collar; if this distance is over 7” (17.8cm), do not proceed and redo all previous work.

  12. Assemble and Torque Bolt

    Assemble the washers and bolt in the following order: Flat washer against the spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten the assembly. Using a torque wrench with a 15/16 socket, tighten the bolt to 50-60 ft.-lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  13. Lubricate Adapters

    Apply the supplied lubricant or an ELASTIMOLD approved lubricant generously to the outside of the cable adapter and the area of the bushing adapter as shown in the documentation. DO NOT SUBSTITUTE other lubricants, as they may be harmful to this product or its mating product.

  14. Seat Receptacle Housing and Ground

    Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the supplied nylon venting rod. Slide the receptacle housing onto the bushing converter until it is fully seated. Remove the venting rod. Connect a short piece of No. 14 AWG copper wire (or equivalent) to the grounding eye of the receptacle housing, making a small loop and twisting tightly without damaging the eye. Gather the concentric neutral wires and, using a suitable connector, connect them with the grounding wire.

  15. Secure Hose Clamp (35kV Only)

    For 35kV installations only, position the hose clamp between the locator bumps on the receptacle housing. Tighten the clamp until an audible click is heard.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.