ABB - Installation Products K656SR-L0330-S - 25kv Straight Receptacle 600 Amp With Sealing Kit, Capacitive Test Points. Cable Insulation Diameter 1.180-1.465 Inches, Aluminum Lug, Conductor Size 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact.

ABB Installation Products K656SR-L0330-S 25kv Straight Receptacle 600 Amp With Sealing Kit, Capacitive Test Points. Cable…

UPC: 075114319072


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656SR-L0330-S is a 25kV straight receptacle designed for reliable electrical connections in medium-voltage applications. This unit operates at 600 Amps and includes a sealing kit for enhanced environmental protection. It features capacitive test points, enabling safe and efficient testing of the circuit without disrupting the main connection. The receptacle is engineered to accommodate cable insulation diameters ranging from 1.180 to 1.465 inches. It is equipped with an aluminum lug for secure conductor termination. The K656SR-L0330-S supports a conductor size of 500 kcmil stranded/compressed or 600 kcmil solid/compact, providing flexibility for various cable types. This ABB Installation Products component ensures robust performance and is suitable for utility, industrial, and commercial power distribution systems where dependable connections are paramount. Its design prioritizes safety and operational efficiency for electrical maintenance and connection tasks. SKU: K656SR-L0330-S. UNSPSC Code: 39121421.
  • 25kV voltage rating for medium-voltage systems
  • 600 Amp continuous current capacity
  • Includes sealing kit for environmental protection
  • Capacitive test points for safe circuit testing
  • Accommodates cable insulation diameters from 1.180-1.465 inches

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amps
Color
Black
Conductor Range
500 kcmil , 600 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions, Fully Submersible
Insulation
True
Length
16.98 in
Length
431.292 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps. Sealing Kit
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle with Test Point
Voltage Rating
15 to 25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

K655LR-J0330

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
25kV, 200 Amp, Straight Receptacle, Deadbreak, Elbow with Cable Adapter, Lug and Retaining Ring, With IEEE Std 386 Capacitive Test Point, and Sealing Kit - SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring. Cable Insulation Diameter 1.180-1.465, Aluminum Lug, Conductor Size 450 kcmil Stranded/Compressed or 500/550 kcmil Compact/Solid.

K656SR-L0320-SG3

25kV, 200 Amp, Straight Receptacle, Deadbreak, Elbow with Cable Adapter, Lug and Retaining Ring, With IEEE Std 386 Capacitive Test Point, and Sealing Kit - SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring. Cable Insulation Diameter 1.180-1.465, Aluminum Lug, Conductor Size 450 kcmil Stranded/Compressed or 500/550 kcmil Compact/Solid.
600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size kcmil Compressed Stranded 900 or Compacted Solid 1000 or mmSquared Compact 500. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K656DLR-N0400-SG3

600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size kcmil Compressed Stranded 900 or Compacted Solid 1000 or mmSquared Compact 500. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 /Compacted Solid 500/550.

K656SR-K0320

600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 /Compacted Solid 500/550.
600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 650 or Compacted Solid 750 or mmSquared Compact 400.

K656SR-L-0360

600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 650 or Compacted Solid 750 or mmSquared Compact 400.
600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 900 or Compacted Solid 1000 or mmSquared Compact 500. Cold-Shrinkable Jacket Seal Included.

K656SR-N0400-S

600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 900 or Compacted Solid 1000 or mmSquared Compact 500. Cold-Shrinkable Jacket Seal Included.
600 Amp, 15/25kV, 600 Series Astraight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Compacted Solid 4/0 or mmSquared Compact 95.

K656SR-H0260

600 Amp, 15/25kV, 600 Series Astraight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Compacted Solid 4/0 or mmSquared Compact 95.
600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 1000.

K656SR-M0410

600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 1000.

Frequently Asked Questions

What is the K656SR product's primary application?

The K656SR provides a fully shielded, submersible cable connection for 15/25kV high-voltage apparatus bushings, allowing straight cable connections on switchgear or electrical apparatus.

Does the K656SR have a test point?

Yes, the K656SR includes a non-corrosive capacitive test point.

What is included in each K656SR kit?

Each kit includes a straight receptacle housing, silicon lubricant, straight receptacle adapter, installation instructions, cable adapter, aluminum compression lug, adapter retaining ring, crimp chart, and hardware prepack.

What material is the K656SR housing made from?

The K656SR features a fully shielded, fully submersible molded rubber housing with 100% peroxide-cured EPDM materials.

Can the K656SR be connected or disconnected energized?

No, the K656SR can only be easily connected or disconnected in a de-energized state.

Does the K656SR meet any industry standards?

Yes, the K656SR meets ANSI/IEEE Standard 386, Latest Revision.

What are the operating voltage limits for 28kV class?

For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase is 28kV.

What are the operating voltage limits for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.

What is the continuous current rating for K656SR?

The K656SR has a continuous current rating of 600 Amps for both 15kV and 28kV voltage classes.

What cable insulation diameters does K656SR support?

The K656SR supports cable insulation diameters ranging from 0.640 inches to 1.935 inches.

How to Install the K656SR/M656SR Straight Receptacle

This guide provides detailed instructions for installing the K656SR and M656SR straight receptacles, which enable an in-line cable connection to standard ANSI-386 600 amp 15kV, 25kV, or 35kV bushings. Ensure all apparatus are de-energized during installation to prevent serious or fatal injury.

Estimated time: 2h

Tools needed:

5/8-11 tap (if applicable), Hex wrench (supplied), Torque wrench with 15/16 socket, Wire strippers, Crimping tool

Supplies needed:

Receptacle housing, Bushing adapter, Cable adapter, Aluminum holding collar, Hex head bolt, Hose clamp (35kV only), Crimp connector, Belleville washer, Flat washer, Nylon venting rod, Lubricant (supplied), Brass bolt, Bushing converter contact, Loctite, Tape marker, No. 14 AWG copper wire (or equivalent), Suitable connector (for neutral and grounding wires), Cable (to be connected)

  1. Prepare Apparatus Bushing

    DANGER: All apparatus must be de-energized during installation. If a stud is present in the apparatus bushing, remove it and re-tap the hole using a 5/8-11 tap. Clean and lubricate the apparatus bushing and bushing converter interface. Apply 3-4 drops of Loctite to the threads of the brass bolt. Assemble the bushing converter onto the apparatus bushing with the bolt hole facing out, using the 5/8” brass bolt. Torque to 60 ft.-lbs.

  2. Cut Cable End Squarely

    Train the cable end and straighten it into its final position. Cut the cable squarely to ensure maximum available length for crimp growth.

  3. Manage Concentric Neutral Wires (If Applicable)

    If applicable, unwrap the concentric neutral wires a distance of 30 inches (76cm). DO NOT CUT them. Bend and fold them back out of the way.

  4. Clean Cable Outer Jacket

    Wipe the outer jacket clean for a distance of 38 inches (96.5cm) or up to the concentric neutral wires.

  5. Slide Receptacle Housing onto Cable

    Slide the receptacle housing onto the cable a distance of 30 inches (76cm).

  6. Prepare Cable Insulation and Install Cable Adapter

    Remove the semi-con shield and install a tape marker to the dimensions shown in the documentation (10-1/4” (26.04cm) from cable end, 11-1/4” (28.58cm) for shield removal). Do not cut or nick the cable insulation. Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  7. Expose Conductor to Correct Length

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. Verify the length of the exposed conductor is 4 3/4” – 5” (12.06cm–12.7cm). If the length is incorrect, redo the assembly from previous steps.

  8. Secure Holding Collar

    Position the holding collar over the conductor and flush against the cable adapter. Using the supplied hex wrench, tighten the setscrew.

  9. Prepare and Insert Conductor into Crimp Connector

    Remove the protective cap from the crimp connector. If using aluminum cable wire, brush the conductor and immediately insert it into the crimp connector, which contains inhibitor. Ensure the conductor is fully inserted into the crimp barrel. Measure the distance from the end of the connector to the holding collar. If this distance is over 7” (17.8cm), do not proceed and redo all previous work.

  10. Confirm Component Alignment

    Confirm that the receptacle housing, cable adapter, crimp connector, and contact adapter are oriented in the correct order as shown in the documentation. Crucially, confirm that the bolt hole in the crimp connector is aligned with the bolt hole in the contact adapter.

  11. Crimp Connectors

    Crimp the connectors following the instructions packaged with the connectors. Rotate each crimp 90 degrees. After crimping, measure the distance from the end of the connector to the holding collar. If this distance is over 7” (17.8cm), do not proceed and redo all previous work.

  12. Assemble and Torque Bolt

    Assemble the washers and bolt in the following order: Flat washer against the spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten the assembly. Using a torque wrench with a 15/16 socket, tighten to 50-60 ft.-lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  13. Lubricate Adapters

    Generously apply the supplied lubricant or ELASTIMOLD approved lubricant to the outside of the cable adapter and the area of the bushing adapter as shown in the documentation. DO NOT SUBSTITUTE other lubricants, as they may be harmful to this product or its mating product.

  14. Seat Receptacle Housing and Connect Ground

    Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the supplied nylon venting rod. Slide the receptacle housing onto the bushing converter until it is fully seated. Remove the venting rod. Connect a short piece of No. 14 AWG copper wire (or equivalent) to the grounding eye of the receptacle housing, making a small loop and twisting tightly. Gather the concentric neutral wires and, using a suitable connector, connect them with the grounding wire.

  15. Install Hose Clamp (35kV Only)

    For 35kV installations only, position the hose clamp between the locator bumps on the receptacle housing. Tighten the clamp until an audible click is heard.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.