ABB - Installation Products K656SR-H5270 - 600 Amp Straight Receptacle with Cable Adapter, Lug and Retaining Ring, with capacitive testpoint, DeadBreak, 15/25KV, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid Compact 250 or mmSquared 126.67.

ABB Installation Products K656SR-H5270 600 Amp Straight Receptacle with Cable Adapter, Lug and Retaining Ring, with capacitive…

UPC: 783786505364


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products K656SR-H5270 is a 600 Amp, 15/25 kV DeadBreak straight receptacle engineered for medium-voltage cable connections in industrial and utility applications. This component features a bi-metal compression lug rated for compressed stranded 4/0 or kcmil solid compact conductors (250 mm² or 126.67 mm²), ensuring reliable electrical continuity and mechanical strength. The cable insulation diameter range of 0.850 inch to 1.050 inch accommodates standard medium-voltage cable sizes, while the integrated retaining ring secures the cable adapter for vibration resistance and pull-out protection. The capacitive test point enables safe, non-intrusive voltage verification without de-energizing the system, reducing downtime during maintenance or testing procedures. This DeadBreak design eliminates the need for load interruption during installation or removal, enhancing operational safety and efficiency. The fully shielded, fully submersible molded rubber housing is constructed with 100% peroxide-cured EPDM materials for superior durability and environmental resistance. Typical applications include switchgear, transformers, motor control centers, and underground distribution systems where medium-voltage power delivery requires robust, field-proven connectors. The bi-metal compression lug provides superior corrosion resistance and long-term conductivity, while the compact footprint of the K656SR series optimizes panel space in densely packed electrical enclosures. The product meets ANSI/IEEE Standard 386 for 15kV and 25kV voltage classes, with ratings including 8.3kV max phase-to-ground, 14.4kV max phase-to-phase, 95kV BIL impulse withstand, and 600 Amp continuous current. For 25kV class, it supports 16.2kV max phase-to-ground, 28kV max phase-to-phase, and 140kV BIL impulse withstand. Optional accessories allow visible external separation, bypass, isolation, dead-ending, grounding, and testing, as well as adding taps.
  • 600 Amp continuous current rating with 25kA symmetrical momentary withstand
  • Bi-metal compression lug for compressed stranded 4/0 or kcmil solid compact conductors (250 mm² or 126.67 mm²)
  • Cable insulation diameter range: 0.850 inch to 1.050 inch
  • Capacitive test point for safe, non-intrusive voltage verification
  • Fully shielded, submersible molded rubber housing with peroxide-cured EPDM materials

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amps
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection
Compression
Connection Type
DeadBreak Receptacle
Current Rating
600 A
Environmental Conditions
All Weather Conditions, Fully Submersible
Insulation
True
Length
16.98 in
Length
431.292 mm
Material
Housing - EPDM-Rubber
Material
Bi-Metal, Plastic
Series
K656SR
Size
0.850" - 1.050"
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle with Test Point
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

162LR-D5270-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
600 Amp, Straight Receptacle with Cable Adapter, Lug and Retaining Ring, DeadBreak, 15/25 KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.

K655SR-J0330

600 Amp, Straight Receptacle with Cable Adapter, Lug and Retaining Ring, DeadBreak, 15/25 KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.
600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.

K656SR-L0330

600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.
15/25kV, Direct Test Elbow, DeadBreak, 600 Amp, Cable Insulation 1.180-1.465 inches, Aluminum Compression Lug, Conductor Size 750 Stranded/Compressed or 900 Solid/Compact.

K656DLR-L0380

15/25kV, Direct Test Elbow, DeadBreak, 600 Amp, Cable Insulation 1.180-1.465 inches, Aluminum Compression Lug, Conductor Size 750 Stranded/Compressed or 900 Solid/Compact.
25kv Straight Receptacle 600 Amp With Sealing Kit, Capacitive Test Points. Cable Insulation Diameter 1.180-1.465 Inches, Aluminum Lug, Conductor Size 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact.

K656SR-L0330-S

25kv Straight Receptacle 600 Amp With Sealing Kit, Capacitive Test Points. Cable Insulation Diameter 1.180-1.465 Inches, Aluminum Lug, Conductor Size 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact.
25kV, 200 Amp, Straight Receptacle, Deadbreak, Elbow with Cable Adapter, Lug and Retaining Ring, With IEEE Std 386 Capacitive Test Point, and Sealing Kit - SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring. Cable Insulation Diameter 1.180-1.465, Aluminum Lug, Conductor Size 450 kcmil Stranded/Compressed or 500/550 kcmil Compact/Solid.

K656SR-L0320-SG3

25kV, 200 Amp, Straight Receptacle, Deadbreak, Elbow with Cable Adapter, Lug and Retaining Ring, With IEEE Std 386 Capacitive Test Point, and Sealing Kit - SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring. Cable Insulation Diameter 1.180-1.465, Aluminum Lug, Conductor Size 450 kcmil Stranded/Compressed or 500/550 kcmil Compact/Solid.
600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size kcmil Compressed Stranded 900 or Compacted Solid 1000 or mmSquared Compact 500. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K656DLR-N0400-SG3

600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size kcmil Compressed Stranded 900 or Compacted Solid 1000 or mmSquared Compact 500. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 /Compacted Solid 500/550.

K656SR-K0320

600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 /Compacted Solid 500/550.

Frequently Asked Questions

What is the K656SR product used for?

The K656SR provides a fully shielded, submersible cable connection on 15/25kV high-voltage apparatus bushings. It allows a straight cable connection on switchgear or electrical apparatus equipped with 600 Amp bushings.

Does the K656SR have a test point?

Yes, the K656SR includes a non-corrosive capacitive test point.

What items are included in the K656SR kit?

Each kit contains a straight receptacle housing, silicon lubricant, a straight receptacle adapter, installation instructions, a cable adapter, an aluminum compression lug, an adapter retaining ring, a crimp chart, and a hardware prepack.

Can the K656SR be connected or disconnected while energized?

No, the K656SR can only be easily connected or disconnected in a de-energized state.

Is the K656SR receptacle submersible?

Yes, the K656SR features a fully shielded and fully submersible molded rubber housing.

What is the impulse withstand rating for 28kV class?

For the 28kV voltage class, the impulse withstand (BIL) is 140kV (1.2 x 50 microsecond wave).

What is the impulse withstand rating for 15kV class?

For the 15kV voltage class, the impulse withstand (BIL) is 95kV (1.2 x 50 microsecond wave).

What is the continuous current rating for K656SR?

The K656SR has a continuous current rating of 600 Amps for both 15kV and 28kV voltage classes.

What are the operating voltage ratings for 28kV class?

For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase is 28kV.

What are the operating voltage ratings for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.

How to Install K656SR and M656SR Straight Receptacles

This guide provides step-by-step instructions for installing K656SR and M656SR Straight Receptacles, which offer an in-line cable connection to standard ANSI-386 600 amp 15kV, 25kV, or 35kV bushings.

Estimated time: 1h 30m

Tools needed:

5/8-11 tap, Hex wrench, Torque wrench (with 15/16 socket), Wire strippers, Brush (for aluminum cable wire), Suitable crimping tool

Supplies needed:

Receptacle housing, Bushing adapter, Cable adapter, Aluminum holding collar, Hex head bolt, Hose clamp (35kV only), Crimp connector, Belleville washer, Flat washer, Nylon venting rod, Lubricant (supplied or ELASTIMOLD approved), Brass bolt, Bushing converter contact, Loctite, Tape marker, No. 14 AWG copper wire (or equivalent), Suitable connector (for neutral and grounding wires)

  1. Prepare the Apparatus Bushing

    DANGER: Ensure all apparatus is de-energized before beginning installation. If a stud is present in the apparatus bushing, remove it and re-tap the hole using a 5/8-11 tap. Clean and lubricate the apparatus bushing and bushing converter interface. Assemble the bushing converter onto the apparatus bushing. Apply 3-4 drops of Loctite to the threads of the brass bolt. Assemble the contact adapter to the apparatus bushing, with the bolt hole facing out, using the 5/8” brass bolt. Torque to 60 ft.-lbs.

  2. Prepare the Cable End

    Train the cable end and straighten it into its final position. Cut the cable squarely to ensure maximum available length for crimp growth. If applicable, unwrap the concentric neutral wires a distance of 30” (76cm), do not cut them, and bend/fold them back out of the way. Wipe the outer jacket clean for a distance of 38” (96.5cm) or up to the concentric neutral wires.

  3. Slide Receptacle Housing and Prepare Cable Insulation

    Slide the receptacle housing onto the cable a distance of 30” (76cm). Remove the semi-con shield and install a tape marker to the dimensions of 10-1/4” (26.04cm) and 11-1/4” (28.58cm) as shown in the documentation. Do not cut or nick the cable insulation. Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield.

  4. Install Cable Adapter and Prepare Conductor

    Install the cable adapter, small end first, until it is flush with the edge of the tape marker. Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. Verify that the length of the exposed conductor is 4 3/4” – 5” (12.06cm–12.7cm); if not, redo the assembly.

  5. Position Holding Collar and Crimp Connector

    Position the holding collar over the conductor and flush against the cable adapter. Using the supplied hex wrench, tighten the setscrew. Remove the protective cap from the crimp connector. If using aluminum cable wire, brush the conductor and immediately insert it into the crimp connector, ensuring it is fully inserted into the crimp barrel. Measure the distance from the end of the connector to the holding collar; if it is over 7” (17.8cm), do not proceed and redo all previous work.

  6. Confirm Orientation and Crimp Connectors

    Confirm that components are oriented in the order: Receptacle Housing, Cable Adapter, Crimp Connector, Contact Adapter. Confirm that the bolt hole in the crimp connectors is aligned with the bolt hole in the contact adapter. Crimp the connectors following the instructions packaged with them, rotating each crimp 90 degrees. After crimping, measure the distance from the end of the connector to the holding collar; if it is over 7” (17.8cm), do not proceed and redo all previous work.

  7. Assemble Washers and Bolt

    Assemble the washers and bolt in the following order: Flat washer against the spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten the assembly. Using a torque wrench with a 15/16 socket, tighten to 50-60 ft.-lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  8. Lubricate and Seat Receptacle Housing

    Apply the supplied lubricant or ELASTIMOLD approved lubricant generously to the outside of the cable adapter and the area of the bushing adapter. DO NOT SUBSTITUTE other lubricants, as they may be harmful. Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the supplied nylon venting rod. Slide the receptacle housing onto the bushing converter until fully seated. Remove the venting rod.

  9. Ground the Receptacle Housing

    Connect a short piece of No. 14 AWG copper wire (or equivalent) to the grounding eye of the receptacle housing. Make a small loop and twist tightly, taking care not to damage the eye. Gather together the concentric neutral wires. Using a suitable connector, connect the neutral wires and the grounding wire.

  10. Secure Hose Clamp (35kV Only)

    FOR 35kV ONLY: Position the hose clamp between the locator bumps on the receptacle housing. Tighten the clamp until an audible click is heard.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.