ABB - Installation Products 168FLR3-B5230 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Connector, Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact.

ABB Installation Products 168FLR3-B5230 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port…

UPC: 075114348089


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 168FLR3-B5230 is a molded current limiting fuse housing designed for electrical protection in medium voltage applications. This unit features a nominal fuse voltage rating of 8.3kV, ensuring safe operation within specified electrical systems. It is equipped with two capacitive test ports, facilitating convenient and accurate fuse testing without requiring system de-energization. The large housing design accommodates a cable insulation diameter ranging from 0.635 inches to 0.905 inches (16-23mm), providing flexibility for various cable sizes. Connection is made via a bi-metal connector, suitable for conductors sized 1 AWG stranded/compressed or 1/0 AWG solid/compact. This fuse housing is manufactured by ABB - Installation Products, a recognized name in electrical infrastructure components. Its construction and specifications are geared towards reliable performance in industrial electrical distribution and protection circuits. The UNSPSC code for this product is 39121421.
  • Nominal Fuse Voltage Rating: 8.3kV
  • Fuse Test Port: Two Capacitive Test Ports
  • Cable Insulation Diameter: 0.635 inch - 0.905 inch / 16-23mm
  • Connector Type: Bi-Metal Connector
  • Conductor Size Compatibility: 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
#1 STR/COMPR AWG , 1/0 SOL/COMPT AWG
Connection Type
Bi-Metal Connector
Insulation
True
Length
21.12 in
Length
536.448 mm
Material
EPDM-Rubber
Size
Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 15kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector
Voltage Rating
8.3 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
11.3500 L
Package Weight (Metric)
5.1480 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.

168AFLR1-B0230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.
15kV, 600 Amp, Elbow Tap Plug, Test and Ground Connector Kit with Test Point. Includes Insulated Cap, Test and Ground Reducing Tap Plug, 600 Series Elbow Housing, Cable Adapter and Tin-Plated Aluminum ShearBolt Lug. Cable Insulation Diameter N - 1.515 to 1.780 inch. Conductor Size AC04 - 750 to 1250 kcmil Stranded/Compressed/Solid/Compact.

656ETP-N-AC04-DRG

15kV, 600 Amp, Elbow Tap Plug, Test and Ground Connector Kit with Test Point. Includes Insulated Cap, Test and Ground Reducing Tap Plug, 600 Series Elbow Housing, Cable Adapter and Tin-Plated Aluminum ShearBolt Lug. Cable Insulation Diameter N - 1.515 to 1.780 inch. Conductor Size AC04 - 750 to 1250 kcmil Stranded/Compressed/Solid/Compact.
8.3kV, 200 Amp, Loadbreak Fused Elbow Connector with Two Direct Test Points. No Sealing Kit. Small Housing - 8-7/8 inches wide x 16-7/6 inches long. Cable Insulation Diameter - 0.635-0.905 inches. Bi-Metal Connector. #2 Stranded/Compressed or #1 Solid/Compact conductor size.

168AFLR1-B5220

8.3kV, 200 Amp, Loadbreak Fused Elbow Connector with Two Direct Test Points. No Sealing Kit. Small Housing - 8-7/8 inches wide x 16-7/6 inches long. Cable Insulation Diameter - 0.635-0.905 inches. Bi-Metal Connector. #2 Stranded/Compressed or #1 Solid/Compact conductor size.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Crimp Connector, Conductor size #4 Stranded/Compressed or #3 Solid/Compact. S - Cold-Shrinkable Jacket Seal.

168FLR1C5200-S

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Crimp Connector, Conductor size #4 Stranded/Compressed or #3 Solid/Compact. S - Cold-Shrinkable Jacket Seal.
8.3kV, Fuse Housing Elbow with Two Direct Test Ports, Small Housing, Cable Insulation Diameter A - 0.575 - 0.740 inch (15-19mm). Bi-Metal Compression Connector. Conductor Size 210 - #2 Solid/Compact.

168AFLR1-A5210

8.3kV, Fuse Housing Elbow with Two Direct Test Ports, Small Housing, Cable Insulation Diameter A - 0.575 - 0.740 inch (15-19mm). Bi-Metal Compression Connector. Conductor Size 210 - #2 Solid/Compact.
8.3kV, 200 Amp, LoadBreak, Fused Elbow (Full Range Current Limiting). Small Housing. Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Connector, Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact. With Jacket Seal

168FLR1B5250-S

8.3kV, 200 Amp, LoadBreak, Fused Elbow (Full Range Current Limiting). Small Housing. Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Connector, Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact. With Jacket Seal
15-25kV, 600 Amp, Deadbreak, 4-Way L-Kit without Test Point, without Seal. 38.18 inch (969.8mm). Cable Insulation Diameter 1.370 - 1.630 inches. Aluminum Compression Lug. Conductor Size 270 - 4/0 kcmil Stranded/Compressed or 270 kcmil Solid/Compact.

K655L4-F0270

15-25kV, 600 Amp, Deadbreak, 4-Way L-Kit without Test Point, without Seal. 38.18 inch (969.8mm). Cable Insulation Diameter 1.370 - 1.630 inches. Aluminum Compression Lug. Conductor Size 270 - 4/0 kcmil Stranded/Compressed or 270 kcmil Solid/Compact.
15kV, 600 Amp, Elbow Tap Plug, Test and Ground Connector Kit with Test Point. Includes Insulated Cap, Test and Ground Reducing Tap Plug, 600 Series Elbow Housing, Cable Adapter and Tin-Plated Aluminum ShearBolt Lug. Cable Insulation Diameter K - 1.090 to 1.310 inch. Conductor Size AC02 - 4/0 to 500 kcmil Stranded/Compressed/Solid/Compact.

656ETP-K-AC02-DRG

15kV, 600 Amp, Elbow Tap Plug, Test and Ground Connector Kit with Test Point. Includes Insulated Cap, Test and Ground Reducing Tap Plug, 600 Series Elbow Housing, Cable Adapter and Tin-Plated Aluminum ShearBolt Lug. Cable Insulation Diameter K - 1.090 to 1.310 inch. Conductor Size AC02 - 4/0 to 500 kcmil Stranded/Compressed/Solid/Compact.

Frequently Asked Questions

What is the maximum rated fuse voltage?

The maximum rated fuse voltage for the 15kV Voltage Class is 10kV.

What is the nominal fuse voltage for the 168FLR?

For the 15kV Voltage Class, the nominal fuse voltage is 8.3kV.

What industry standards does the 168FLR meet?

The 168FLR meets IEEE 386, ANSI C37.40, ANSI C37.41, and ANSI C37.47, Latest Revision.

What is the primary application of the 168FLR?

The 168FLR improves distribution system reliability by protecting light duty underground distribution systems, including sub-loops and radial taps. It replaces existing 200 Amp loadbreak tap elbows.

What is the current rating range of the 168FLR?

The current rating for the 168FLR is 3-80 Amp.

What is the symmetrical interrupting capability?

The symmetrical interrupting capability is 50,000 Amp.

Is the 168FLR fused elbow submersible?

Yes, the 168FLR is fully sealed and submersible.

What items are included in the 168FLR kit?

Each kit contains an elbow connector housing, a crimp connector, a probe lug, lubricant tubes, installation instructions, and a crimp chart.

What types of conductors are compatible with the lugs?

Copper compression lugs are suitable for copper conductors only. Bi-metal compression lugs are suitable for copper or aluminum conductors.

Is the 168FLR fused elbow submersible?

Yes, the 168FLR is fully sealed and submersible.

How to Install the 168FLR Loadbreak Fused Elbow Connector

This guide provides step-by-step instructions for the safe installation and initial assembly of the 168FLR Loadbreak Fused Elbow Connector, including cable preparation, component assembly, and grounding.

Estimated time: 2h

Tools needed:

Probe Wrench, Allen Wrench (torque limiting), Wire brush, Crimp tool, Hotstick

Supplies needed:

Cable Half Housing, Elbow Half Housing, Fuse, Compression Lug, Probe, Probe Connector, Hose Clamp, Lubricant (silicone), No. 14 AWG copper wire, Terminal connectors

  1. Perform Pre-Installation Checks and Ensure Safety

    Before starting, ensure all apparatus are de-energized. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Check threads by threading the probe into the compression lug; replace damaged components if resistance is encountered. Have all required tools ready and maintain cleanliness throughout the procedure.

  2. Prepare the Cable for Termination

    Using the bushing centerline as a reference, cut excess cable, then remove the jacket for a specified length (20 inches minimum plus 'A' + 7-3/8 inches). If using a Cable Seal kit, follow its instructions. Otherwise, unwrap and fold the concentric neutral wires back over the jacket and bind them. Squarely cut off the cable a distance of 'A' from the bushing centerline, leaving 7-3/8 inches minimum of cable to terminate. 'A' is 11-1/2 inches for FLR-1 or 15-3/4 inches for FLR-3.

  3. Prepare Cable End and Install Compression Lug

    Cut 1-1/8 inches from the cable end, ensuring a square cut without nicking the conductor. Wire brush bare aluminum conductors immediately. Install the compression lug by crimping its unthreaded end to the conductor, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Refer to the crimp chart provided with the lug. Carefully wipe any excess inhibitor from the lug and cable. Remove the insulation shield 5-1/2 inches from the end of the lug and bevel the insulation end by 1/8 inch maximum. Thoroughly clean the insulation to remove all traces of conductive residue.

  4. Lubricate and Assemble Cable Half

    Apply the supplied lubricant to the outside of the connector, the cable insulation, the conductive shield, and the cable entrance end of the Fused Elbow cable half. Do not substitute lubricant. Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface 'A'. This positioning allows the fuse to be tightened before bottoming on the rubber.

  5. Install and Hand Tighten the Fuse

    Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and thread it into the cable connector. Hand tighten the fuse. CAUTION: The fuse stud will fracture if over-torqued. After hand tightening, pull the housing up against the bottom of the tightened fuse.

  6. Assemble and Lock the Probe Connector

    Assemble the probe connector to the fuse terminal. Rotate the probe connector so that its flats are perpendicular to the bushing with which it will mate. Lock the probe connector in position by tightening the setscrews using the special torque-limiting allen wrench supplied in the fuse kit. Rotate the cable half of the Fused Elbow so that the test point is perpendicular to the flats on the probe connector.

  7. Assemble Elbow Half and Probe

    Apply lubricant to the elbow half of the fused elbow and assemble it to the cable half. The cuff of the cable half will overlap the elbow half by 3/4 inch. Ensure the probe connector faces the opening of the fused elbow half and that the two test points are in line with each other. Insert the probe into the probe connector, pushing on the cable if necessary to align it with the fuse. Start the threads by hand, taking care not to cross-thread. Tighten using the special torque-limiting allen wrench supplied; insert the short end into the hole in the probe and tighten until the wrench bends and remains bent. Position the hose clamp and tighten it. DO NOT OVERTIGHTEN the hose clamp.

  8. Connect Concentric Neutral Wires to Ground

    Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through each grounding eye on the elbow housing and cable housings. Twist tightly, taking care not to damage the eyes. If a 200ECS jacket seal is used, finish installing it. Twist all neutral wires together, exercising care not to damage grounding eyes, and connect them to ground using an appropriate connector. Provide adequate slack in the wires to allow for elbow operation.

  9. Connect the Elbow to the Bushing Plug

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Operate the connection using a full insulated 'hotstick' type tool as per company safe work practices; DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.