ABB - Installation Products K655DLR-L0240-S - 15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.180-1.465 inches, Aluminum Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact. Sealing Kit - Cold Shrinkable Jacket Seal.

ABB Installation Products K655DLR-L0240-S 15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.180-1.465 inches…

UPC: 075114333078


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655DLR-L0240-S is a 15/25kV, 600 Amp deadbreak direct test elbow designed for medium-voltage cable systems. This fully rated elbow connector incorporates ABB’s Elastimold® Direct Test System (EDTS), enabling safe live-line voltage testing, isolation, and grounding without system de-energization. The integrated test port allows direct conductor voltage verification using a 600TC series meter adapter, reducing downtime and improving maintenance efficiency. Key specifications include a 1.180–1.465 inch cable insulation range, compatible with 1/0 stranded/compressed or 2/0 solid/compact conductors. The aluminum compression lug ensures low-resistance terminations, minimizing heat generation and power loss. A cold shrinkable jacket seal provides environmental protection against moisture, dust, and contaminants, making the unit suitable for outdoor and underground installations. The K655DLR-L0240-S meets ANSI/IEEE Standard 386 requirements, with ratings including 8.3kV phase-to-ground and 14.4kV phase-to-phase operating voltages, 95kV BIL impulse withstand, and 600 Amp continuous current. The fully shielded, submersible molded rubber housing ensures reliable performance in harsh conditions. Optional accessories enable visible separation, bypass, isolation, dead-ending, grounding, and fault current indication. Ideal for medium-voltage switchgear, transformers, and cable terminations in utility, industrial, and commercial power distribution systems, this elbow connector delivers durable, maintenance-friendly solutions for critical infrastructure.
  • 15/25kV voltage rating, 600 Amp continuous current
  • Deadbreak design enables live-line testing without de-energization
  • Aluminum compression lug for 1/0 stranded/compressed or 2/0 solid/compact conductors
  • Cold shrinkable jacket seal for environmental protection
  • Cold shrinkable jacket seal for environmental protection (1.180–1.465 inch cable insulation range)

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amps
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Connection
Compression
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Size
Cable Insulation 1.180-1.465 inches
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators. Direct conductor test point equipped elbow
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Direct Test Elbow Connector
Voltage Rating
15 to 25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .635-.905 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.

252LR-B5240

25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .635-.905 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
15/25kv, 600 Amps, Deadbreak Direct Test Elbow without Test Point. With Cold-Shrinkable Jacket with Copper Braid and Constant Force Spring. Universal Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 350 Compacted, Solid 400.

K655DLR-J0300-SG3

15/25kv, 600 Amps, Deadbreak Direct Test Elbow without Test Point. With Cold-Shrinkable Jacket with Copper Braid and Constant Force Spring. Universal Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 350 Compacted, Solid 400.
15/25kv, 600 Amps, Deadbreak Direct Test Elbow without Test Point. With Cold-Shrinkable Jacket with Copper Braid and Constant Force Spring. Universal Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 Compacted, Solid 250.

K655DLR-H0270-SG3

15/25kv, 600 Amps, Deadbreak Direct Test Elbow without Test Point. With Cold-Shrinkable Jacket with Copper Braid and Constant Force Spring. Universal Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 Compacted, Solid 250.
15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.280-1.430 inches, Aluminum Compression Lug, Conductor Size 350 Stranded/Compressed or 400 Solid/Compact. Sealing Kit - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

K655DLR-LM0300-SG3

15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.280-1.430 inches, Aluminum Compression Lug, Conductor Size 350 Stranded/Compressed or 400 Solid/Compact. Sealing Kit - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .805-1.060 inch Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.

252LR-C5240

25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .805-1.060 inch Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 250 Compacted, Solid 3/0. Cold-Shrinkable Jacket with Copper Braid and Constant Force Spring.

756LR-K0250-SG3

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 250 Compacted, Solid 3/0. Cold-Shrinkable Jacket with Copper Braid and Constant Force Spring.
15/25kv, 600 Amps, Deadbreak Elbow without Test Point. Bi-Metal Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.

K655LR-J5300

15/25kv, 600 Amps, Deadbreak Elbow without Test Point. Bi-Metal Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, #2 Stranded/Compressed or #1 Solid/Compact Wire Size, Bi-Metal Compression Lug, Sealing Kit - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

162LR-D5220-SG3

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, #2 Stranded/Compressed or #1 Solid/Compact Wire Size, Bi-Metal Compression Lug, Sealing Kit - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

Frequently Asked Questions

What is the K655DLR Direct Test Elbow used for?

It is a fully rated 15/25kV, 600 Amp Class deadbreak elbow connector that incorporates the Elastimold Direct Test System (EDTS) for isolation, testing, and grounding.

What industry standard does the K655DLR meet?

The K655DLR Direct Test Elbow meets ANSI/IEEE Standard 386, Latest Revision.

What cable insulation diameters are supported?

Supported cable insulation diameters range from 0.640 in to 1.935 in (16.256 mm to 49.149 mm), corresponding to various W codes.

What components are included in the K655DLR kit?

The kit includes an elbow connector housing, a copper compression lug, a stud, an insulated plug with cap, lubricant, a cable adapter, and installation instructions.

Is the K655DLR elbow submersible?

Yes, the K655DLR features a fully shielded, fully submersible molded rubber housing.

What is the continuous current rating of the elbow?

The K655DLR Direct Test Elbow has a continuous current rating of 600 Amps for both 15kV and 28kV voltage classes.

What are the operating voltage ratings for 28kV class?

For 28kV class, the maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase is 28kV.

What are the operating voltage ratings for 15kV class?

For 15kV class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.

What is the Elastimold Direct Test System (EDTS)?

EDTS is an insulated port on the separable connector providing a direct path to the conductor. It allows direct conductor voltage testing with a 600TC series meter adapter.

What conductor sizes are compatible with the K655DLR?

Compatible conductor sizes range from 2 AWG (35 mm2) to 1250 kcmil (500 mm2), supporting various strand, compact, and universal types.

How to Install K655/K675DLR Direct Test Elbow Connectors

A comprehensive guide for the safe and proper installation of K655/K675DLR Direct Test Elbow Connectors, including cable preparation, lug crimping, and connection to high voltage apparatus.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Wire brush (for aluminum conductors), Crimping tool, Torque wrench, Hotstick tool, Screwdriver

Supplies needed:

K655/K675DLR Elbow, Cable Adapter, Compression Lug, Insulating Plug (optional), Lubricant, Stud Prepack, Vinyl plastic tape (if needed), Tape retainer (if needed), Tape marker (if needed), No. 14 AWG copper grounding wire (or equivalent), Suitable grounding connector, Waterproofing material (recommended), Threaded stud (if mating part not equipped)

  1. De-energize and Position Cable

    DANGER: All apparatus must be de-energized during installation or removal of parts to prevent serious or fatal injury. Position the cable in its final assembled location, ensuring enough slack for elbow removal. If using concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product.

  2. Clean and Prepare Cable Jacket and Shield

    Clean the outer surface of the cable for a distance of 24” (610mm) or up to the bent back concentric neutral wires. Remove the outer jacket to 12-3/4” (324mm). Fold back shield wires, or remove flat metallic tape shield to 10-3/4” (273mm) and secure with vinyl plastic tape. For fabric tape shield, remove it and install a tape retainer and tape marker to specified dimensions. For longitudinally corrugated shield, remove it and install a tape marker to 10-3/4” (273mm). For semi-con shield, remove it and install a tape marker to dimensions. Do not cut or nick the cable insulation during this process.

  3. Prepare Cable Insulation and Install Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean the cable insulation, then lubricate it, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Expose Conductor and Install Compression Lug

    Remove any protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. Verify the exposed conductor length is between 4-3/8” (111mm) to 4-11/16” (119mm); otherwise, redo the assembly. For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it. Crimp the compression lug following the instructions supplied with the lug. Wipe all excess inhibitor from the lug and cable adapter surface after crimping. Verify the distance from the end of the compression lug to the cable adapter is between 6-1/2” to 7-1/4” (165mm – 184mm) after crimping.

  5. Install Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.

  6. Connect to Mating Product

    DANGER: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from the elbow and the mating part. If the mating part is not equipped with a stud, hand-tighten the threaded stud supplied with the elbow into it. Clean and lubricate both the elbow and the mating part with the supplied lubricant. Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part.

  7. Secure Opposite End (if applicable) and Ground Cable Shield

    If connecting another mating part to the opposite end of the elbow, clean and lubricate its inner surface, insert it into the elbow, engage the threads, and hand-tighten. Torque the mating part according to its supplied instructions. Ground the cable shield by inserting one end of a No. 14 AWG copper wire (or equivalent) through the grounding eye, twisting it to form a small loop, and connecting it to ground using a suitable connector. Ground the shield according to the instructions supplied with the grounding device, or by an alternate method if no device is used. It is recommended to waterproof the cable jacket at this point to prevent moisture entry.

  8. Install Insulating Plug (Optional)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down hard until it snaps into place. Refer to separate instructions for direct voltage testing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.