ABB Installation Products K655CCP-H0270 15/25kV, 600 Amp, no test point, Combo T Connecting Plug with Stud, Cable Adapter and…
UPC: 075114363877
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Rated for 15/25kV, 600A systems with no test point required
- Accommodates conductor sizes from 4/0 AWG to 250 kcmil (compressed/stranded or solid/compacted)
- Supports cable insulation diameters from 0.850 inch to 1.050 inch (21.6 mm to 26.7 mm)
- Includes aluminum compression lug for reliable electrical contact and mechanical strength
- Kit components: elbow connector housing, stud, compression lugs, lubricant, cable adapter, installation instructions, and crimp chart
Specifications
Amperage Rating | 600 A |
Color | Black |
Conductor Range | 4/0 STR/COMPR AWG , 250 kcmil |
Connection | Compression |
Connection Type | Compression Lug |
Current Rating | 600 A |
Insulation | True |
Material | Aluminum |
Material | Housing - EPDM-Rubber |
Material | Aluminum Compression Lug |
Series | K655CCP |
Size | Cable Insulation Diameter 0.850 inch to 1.050 inch |
Size | Cable Insulation Diameter 0.850-1.050 inches |
Special Features | The hollow bore of the ComboT allows visual validation that the compression lug is positioned properly before the snuffer/bus is inserted and tightened |
Standard | ANSI/IEEE Standard 386 |
Type | ComboT Connecting Plug |
Voltage Rating | 15/25 kV |
Voltage Rating | 15 to 25 kV |
Width | 10 in |
Width | 254 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

162LR-C5270-S
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
252LR-C2070
12/20 24kV, 250 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable Insulation Diameter - 20.45 mm - 26.92 mm, Copper Compression Lug, Conductor Size 70mm. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide. IEC Standard.
252LR-C2095
12/20 24kV, 250 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable Insulation Diameter - 20.45 mm - 26.92 mm, Copper Compression Lug, Conductor Size 95mm. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide. IEC Standard.
261DLR-C5240
25kV, 200 Amps, Loadbreak Elbow with Direct Test Port. Cable Insulation Diameter Code C - 0.805 to 1.060 inch. Bi-Metal Compression Lug, Conductor Size 240 - 1.0 Stranded/Compressed or 2/0 Solid/Compact.
K655L3-K0240
15/25kV 600 Series Deadbreak 3-Way L-Kit, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.
K655L3-2M0400-K0310
600 Amp, 15/25kV 600 Series Deadbreak 3-Way L-Kit, 2 X ( Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. ) 1 X ( Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240. )
655LINKCLRN0410ADRG
600 Amp, 15kV, Deadbreak RetroFit Cam-Op Connector Kit with Insulated Cap, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
K655CCP-M0380
15/25kV, 600 Amp, no test point, Combo T Connecting Plug with Stud, Cable Adapter and Lug Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.Frequently Asked Questions
What is a critical safety precaution for installation?
The system must be de-energized before initiating any installation of the ComboT connectors.
What is a critical safety precaution for installation?
The system must be de-energized before initiating any installation of the ComboT connectors.
What is a critical safety precaution for installation?
The system must be de-energized before initiating any installation of the ComboT connectors.
How much does the ComboT connector reduce stack height?
Each combination elbow/connecting plug reduces the stack height by 2.67 inches.
What tools are required for ComboT installation?
The ComboT installs with standard assembly tools and uses a standard 600 or 900 series stud.
How are ComboT interfaces color-coded by voltage?
IEEE 386 color-coded PBT interfaces are red for 15 kV reducing tap and blue for 25 kV reducing tap.
What is the torque specification for the CCP bus?
When installing the CCP bus, torque to 50 to 60 ft.-lbs.
What are the continuous current ratings?
Continuous current ratings are 600 A for deadbreak and 200 A for loadbreak reducing taps, or 600 A and 900 A for connecting plugs/bushing wells.
What voltage classes do ComboT connectors support?
ComboT connectors support 15 kV and 25 kV voltage classes for reducing taps, and 15/25/28 kV for connecting plugs and bushing wells.
How are ComboT interfaces color-coded by voltage?
IEEE 386 color-coded PBT interfaces are red for 15 kV reducing tap and blue for 25 kV reducing tap.
How to Install K655/K656CCP Deadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of K655/K656CCP Deadbreak Elbow Connectors on 15kV or 25kV class systems, including cable preparation, lug crimping, and connection to mating apparatus.
Estimated time: 2h
Tools needed:
Crimping tool, Wire brush (for aluminum conductors), 600 ATM assembly tool, Hotstick (for K656CCP voltage test), Suitable sensing device (for K656CCP voltage test)
Supplies needed:
Lubricant (supplied), Vinyl plastic tape (if applicable), Tape retainer (if applicable), Tape marker (if applicable), Wire (at least No. 14 AWG Copper), Suitable ground connector, Silicone grease (for K656CCP test point cap), Compression Lug (supplied), Cable Adapter (supplied), Elbow (supplied), Stud (supplied)
- Prepare for Installation and Safety Check
Review the contents of the package to ensure all parts are complete and undamaged. Inspect all components for proper fit with the cable and/or mating products. Ensure all apparatus are de-energized during installation or removal of parts to prevent serious or fatal injury. Have all required tools at hand and maintain cleanliness throughout the procedure.
- Position and Cut Cable
Position the cable in its final assembled location, allowing enough slack for adequate clearance to remove the elbows. For concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.
- Clean Cable Outer Surface
Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent-back concentric neutral wires.
- Prepare Cable Jacket and Shield
Follow the instructions that apply to your specific cable type for removing the outer jacket and preparing the shield. This may involve removing the outer jacket to 12-3/4 inches (324mm), folding back shield wires, removing flat metallic tape shield and securing with vinyl plastic tape, or removing fabric/corrugated shields and installing tape retainers/markers. For UNISHIELD* or lead sheath cables, refer to the 10TL cable shield adapter instructions.
- Prepare Semi-Con Shield and Cable Insulation
Remove the semi-con shield to the dimensions shown (9-3/4 inches or 248mm, and 10-3/4 inches or 273mm), ensuring not to cut or nick the cable insulation. Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back.
- Clean, Lubricate, and Install Cable Adapter
Thoroughly clean and then lubricate the cable insulation, always working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.
- Trim Insulation and Verify Conductor Length
Remove any protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor should be 4-3/8 inches to 4-11/16 inches (111mm-119mm). If the length is incorrect, redo the assembly.
- Prepare Conductor and Crimp Compression Lug
For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping (it should be less than 6-1/2 inches or 165mm). Crimp the compression lug following the crimping instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping should be 6-1/2 inches to 7-1/4 inches (165mm-184mm); otherwise, redo the assembly.
- Lubricate and Install Elbow
Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter is still flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.
- Prepare Mating Products
DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from the elbow and the mating part. Install the stud in the mating part. Clean and lubricate both the elbow and the mating part with the lubricant supplied, ensuring surfaces remain clean.
- Connect Elbow to Mating Part
Push the elbow onto the mating part. Using the 600 ATM assembly tool, thread the connector into the mating part until it bottoms. Apply 50 to 60 foot-pounds of torque.
- Ground the Connector and Cable Shield
Insert one end of a wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded according to the instructions supplied with any grounding device, or through an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.
- Install Additional Mating Connectors (Optional)
If applicable, clean and lubricate the entire male interface and either a DR(G), GLR, or LR connector of the appropriate voltage class with the supplied or ELASTIMOLD® approved lubricant. Install the DR(G), GLR, or LR to the bushing interface following the instructions supplied with those specific products.
- Perform Voltage Test (K656CCP Only)
For K656CCP connectors, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the meter used. Test with a suitable sensing device designed for capacitive test points to determine if the cable is energized. Contamination, moisture, or incorrect equipment can give a false 'no voltage' indication; treat the elbow as energized until confirmed by other means. After testing, clean, lubricate the inside surface of the cap with silicone grease, and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.