Authorized ABB Distributor (Installation Products)
ABB - Installation Products K465LR-LM-2360 - 15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 1.280 inch to 1.430 inch (29.972-37.211mm). Copper Compression Lug, Conductor Size 650 Stranded/Compressed or 750/800 Solid/Compact. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

ABB Installation Products K465LR-LM-2360 15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 1.280…

UPC: 783786362783


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K465LR-LM-2360 is a 15/25kV, 630 Amp deadbreak elbow connector designed for reliable cable termination. This model specifically excludes a test point, simplifying installation and reducing potential points of failure in certain applications. It is engineered to accommodate cable insulation diameters ranging from 1.280 inches to 1.430 inches (29.972-37.211mm). Key components include a copper compression lug, suitable for conductor sizes of 650 kcmil stranded/compressed or 750/800 kcmil solid/compact conductors. The kit comes complete with the elbow connector housing, compression lug, stud, an insulated plug with cap, tube lubricant, cable adapter, and comprehensive installation instructions with a crimp chart. This deadbreak elbow exceeds the latest revision of the ANSI/IEEE Standard 386, ensuring adherence to critical industry safety and performance benchmarks. This product is ideal for medium voltage power distribution systems where a robust and dependable connection is paramount. Its construction and specifications are geared towards ensuring electrical integrity and operational safety in power infrastructure. UNSPSC Code: 39121421. Manufacturer: ABB - Installation Products.
  • 15/25kV voltage rating
  • 630 Amp continuous current rating
  • Deadbreak elbow connector without test point
  • Accommodates cable insulation diameters from 1.280" to 1.430" (29.972-37.211mm)
  • Includes copper compression lug for 650 kcmil stranded/compressed or 750/800 kcmil solid/compact conductors

Specifications

Amperage Rating
630 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
650 kcmil , 750 to 800 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators
Standard
ANSI/IEEE Standard 386/ IEC
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15 to 25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
7.3400 L
Package Weight (Metric)
3.3290 kg
15/25kV 600 Series Deadbreak 3-Way L-Kit, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

K655L3-LM0360

15/25kV 600 Series Deadbreak 3-Way L-Kit, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch (27.686-33.274mm). Copper Compression Lug, Conductor Size 400 Stranded/Compressed or 450 Solid/Compact or 240 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-K-2310

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch (27.686-33.274mm). Copper Compression Lug, Conductor Size 400 Stranded/Compressed or 450 Solid/Compact or 240 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.640-0.820 inches (16.256-20.828mm). Aluminum Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Solid/Compact or 35 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-F-0220

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.640-0.820 inches (16.256-20.828mm). Aluminum Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Solid/Compact or 35 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.900 inch to 2.120 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1250. Cold-Shrinkable Jacket Seal Included.

776LR-Q5440-S

900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.900 inch to 2.120 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1250. Cold-Shrinkable Jacket Seal Included.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.850-1.050 inches (21.590-26.670mm). Aluminum Compression Lug, Conductor Size 400 Stranded/Compressed or 450 Solid/Compact or 240 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-H0310

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.850-1.050 inches (21.590-26.670mm). Aluminum Compression Lug, Conductor Size 400 Stranded/Compressed or 450 Solid/Compact or 240 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
900 Amp, 35KV, DeadBreak, Direct Test Elbow with insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

775LR-J2250

900 Amp, 35KV, DeadBreak, Direct Test Elbow with insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

756LR-L0260

600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
900 Amp, 35KV, DeadBreak, Elbow with Test Point, with insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

776LR-J2240

900 Amp, 35KV, DeadBreak, Elbow with Test Point, with insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

Frequently Asked Questions

What is the K465LR elbow connector used for?

The K465LR provides fully shielded, dead-front submersible cable connections for high-voltage apparatus.

What is the K465LR's impulse withstand rating?

The K465LR has a 140kV BIL impulse withstand rating (1.2 x 50 microsecond wave).

How is the K465LR connected or disconnected?

The K465LR can be easily connected or disconnected using standard hand tools and equipment, but only in a de-energized state.

Is the K465LR submersible?

Yes, the K465LR features a fully shielded, fully submersible molded rubber housing.

What is the maximum continuous current rating?

The maximum continuous current rating is 1250 Amp, provided the connected equipment is also rated for 1250A.

What is the continuous current rating?

The continuous current rating for the K465LR is 630 Amp.

What is the maximum phase-to-phase voltage?

The maximum phase-to-phase voltage for the K465LR is 28kV.

What is the maximum phase-to-ground operating voltage?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV.

What standard does the K465LR exceed?

The K465LR exceeds ANSI/IEEE Standard 386, Latest Revision.

What are the K465LR's bushing interface standards?

One end conforms to IEC-71 for 630A European Switchgear, and the other has a standard ANSI 386 Fig 11 bushing interface.

How to Identify the M16 to 5/8-11 Thread Conversion Stud

This guide provides instructions to correctly identify the M16 metric and 5/8-11 English threaded ends of the conversion stud included in the kit.

Estimated time: 5m

  1. Locate the Conversion Stud

    Find the double-ended stud that provides conversion from M16 metric thread to 5/8”-11 English thread within the enclosed kit.

  2. Identify the M16 Metric End

    Examine the stud for an end marked with the letter 'M'. This marking indicates the M16 metric threaded end.

  3. Identify the 5/8-11 English End

    The end of the stud that is not marked with an 'M' is the 5/8”-11 English threaded end.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.