ABB - Installation Products K465LR-F-0220 - 15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.640-0.820 inches (16.256-20.828mm). Aluminum Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Solid/Compact or 35 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

ABB Installation Products K465LR-F-0220 15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter…

UPC: 783786392834


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K465LR-F-0220 is a 15/25kV, 630 Amp deadbreak elbow connector designed for reliable power distribution applications. This unit operates without a test point, simplifying installation and reducing potential points of failure. It is engineered to accommodate cable insulation diameters ranging from 0.640 to 0.820 inches (16.256 to 20.828mm). The connector features an aluminum compression lug, suitable for conductor sizes including #2 Stranded/Compressed, #1 Solid/Compact, or 35 mm². Included with the K465LR-F-0220 are all necessary components for a complete installation: the elbow connector housing, the aluminum compression lug, a stud, an insulated plug with cap, tube lubricant, a cable adapter, and comprehensive installation instructions complete with a crimp chart. This product exceeds the latest revision of the ANSI/IEEE Standard 386, ensuring adherence to established industry benchmarks for performance and safety. The UNSPSC code for this product is 39121421. Manufacturer: ABB - Installation Products. SKU: K465LR-F-0220.
  • 15/25kV, 630 Amp rating for robust power handling.
  • Designed for cable insulation diameters from 0.640-0.820 inches (16.256-20.828mm).
  • Accommodates #2 Stranded/Compressed, #1 Solid/Compact, or 35 mm² conductors.
  • Includes aluminum compression lug and all necessary installation components.
  • Exceeds ANSI/IEEE Standard 386 (latest revision) for assured compliance.

Specifications

Amperage Rating
630 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Connection
Compression
Connection Type
Compression Lug
Current Rating
630 A
Environmental Conditions
All Weather Conditions
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Material
Aluminum, Poly
Series
K465LR
Size
Cable Insulation Diameter 0.640-0.820 inches (16.256-20.828mm)
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators
Standard
ANSI/IEEE Standard 386/ IEC
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
7.2500 L
Package Weight (Metric)
3.2890 kg
28kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.

262LR-C5220

28kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.
900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.900 inch to 2.120 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1250. Cold-Shrinkable Jacket Seal Included.

776LR-Q5440-S

900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.900 inch to 2.120 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1250. Cold-Shrinkable Jacket Seal Included.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.850-1.050 inches (21.590-26.670mm). Aluminum Compression Lug, Conductor Size 400 Stranded/Compressed or 450 Solid/Compact or 240 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-H0310

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.850-1.050 inches (21.590-26.670mm). Aluminum Compression Lug, Conductor Size 400 Stranded/Compressed or 450 Solid/Compact or 240 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
900 Amp, 35KV, DeadBreak, Direct Test Elbow with insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

775LR-J2250

900 Amp, 35KV, DeadBreak, Direct Test Elbow with insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

756LR-L0260

600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
900 Amp, 35KV, DeadBreak, Elbow with Test Point, with insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

776LR-J2240

900 Amp, 35KV, DeadBreak, Elbow with Test Point, with insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.

756LR-P0400

600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.
900 Amp, 35KV, DeadBreak, Elbow with Test Point, with insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

776LR-K2250

900 Amp, 35KV, DeadBreak, Elbow with Test Point, with insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

Frequently Asked Questions

What is the K465LR elbow connector used for?

The K465LR provides fully shielded, dead-front submersible cable connections to high-voltage apparatus. It is designed for use through 28kV.

What are the interface standards for the K465LR?

One end conforms to IEC-71 for 630 A European Switchgear, and the other end has a standard ANSI 386 Fig 11 bushing interface.

What items are included in a K465LR kit?

Each kit includes an elbow connector housing, copper compression lug, stud, insulated plug with cap, lubricant tubes, cable adapter, and installation instructions.

What is the short circuit rating of the K465LR?

The short circuit rating is >28 kA RMS symmetrical and >70 kA peak asymmetrical.

Is a grounding device needed for certain cable types?

Yes, an ECS cable seal grounding device is recommended when using metallic tape shield or drain wire cable.

What are the insulation diameter requirements for cables?

The K465LR accommodates cable insulation diameters from 0.640 inches to 1.935 inches.

What is the continuous current rating of this elbow?

The continuous current rating is 630 Amps. It can handle 1250 Amps if the connected equipment is also rated for 1250A.

What is the maximum operating voltage for the K465LR?

The maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase is 28kV for the 25kV voltage class.

What conductor types and sizes are compatible?

It is compatible with aluminum and copper conductors ranging from 1/0 to 1250 kcmil.

How do I select the correct catalog number?

To select the catalog number, determine the cable's insulation diameter for the W code, choose the connector material, and select the compression lug code (X code) based on conductor size.

How to Identify and Use the M16 to 5/8-11 Thread Conversion Stud

This guide explains how to identify the M16 and 5/8-11 ends of the double-ended stud for thread conversion, as described in the provided documentation.

Estimated time: 1m

  1. Locate the M16 Threaded End

    Examine the double-ended stud. The M16 metric threaded end is clearly marked with an 'M' for easy identification, as indicated in the documentation.

  2. Identify the 5/8-11 English Threaded End

    The opposite end of the stud, which does not have the 'M' marking, is the 5/8-11 English threaded end. This end is designed to interface with 5/8-11 English threads.

  3. Utilize for Thread Conversion

    Use the double-ended stud to provide a conversion between M16 metric threads and 5/8-11 English threads as needed for your specific application. Ensure proper alignment and threading to prevent damage to the threads.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.