ABB Installation Products K151SR-B0260 15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included…
UPC: 075114403801
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25kV Voltage Rating
- 200 Amp Continuous Current Rating
- Deadbreak Straight Receptacle Configuration
- Accommodates Cable Insulation Diameter: 0.635" - 0.905"
- Aluminum Compression Lug for 3/0 AWG Stranded or 4/0 AWG Solid Conductors
Specifications
Amperage Rating | 200 A |
Application | Designed to connect a cable to another cable or apparatus |
Color | Black |
Conductor Range | 3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG |
Environmental Conditions | Fully Shielded, Fully Submersible |
Insulation | True |
Length | 9.54 in |
Length | 242.316 mm |
Material | Housing - EPDM-Rubber |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Straight Receptacle |
Voltage Rating | 15 to 25 kV |
Width | 2.74 in |
Width | 69.596 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

376LR-J-5260
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
K656YSR-H0230
600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0.
K151SP-B0260
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Solid 4/0.
755ETP-N0360-DRG
600 Amp, 35kV, Deadbreak, Test and Ground Connector kit, includes Insulated cap, reducing tap plug, elbow housing, cable adapter and 0370 style compression lug. 600ATM assembly tool required, 50-60 foot/pounds torque wrench required but not included. Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed Stranded 500 kcmil or Compacted Solid 600 I
262LR-D5230-SG3
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.890-1.220 inches (22.61-30.99mm), Bi-Metal Lug, Conductor Size 230 - #1 Stranded/Compressed or 1/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 9.03 inches tall, 2.097 inch diameter. Includes SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
375LR-H5250-S
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG 3/0 Compressed/Stranded or 2/0 Solid/Compact. S - Cold-Shrinkable Jacket Seal.
656CETP-H0250
15kV, 600 Series ComboT Elbow with 200 Amp Reducing Tap Plug, Stud, Cable Adapter and Lug Kit, with Test Point. Cable Insulation Diameter Range 0.850 to 1.050 inches, Aluminum Lug, 2/0 Stranded/Compressed or 3/0 Solid/Compact.
K655LINK-C-DP0594953
25kV, 600 Amps, Deadbreak Cam-Op Connector Kit. Cable Insulation Diameter LM - 1.280 to 1.630 inch, 700/750 Stranded/Compressed kcmil or 900 Solid/Compact kcmil. Contains (1) Cam-Op Link, (1) Elbow Housing, (1) cable Adapter, (1) Aluminum Compression Lug, (1) Bushing Extender, (2) Retainer Sleeves, (1) Insulated Cap, (1) Mountable Insulated Bushing and (1) Alignment Brackets.Frequently Asked Questions
What is the K151SR receptacle's primary function?
The K151SR Straight Receptacle is a fully shielded, fully submersible, separable insulated connector designed to connect a cable to another cable or apparatus.
What is the maximum phase-to-ground operating voltage for 15kV class?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.
What is the impulse withstand (BIL) for the 25kV class?
For the 25kV voltage class, the impulse withstand (BIL) is 125kV (1.2 x 50 microsecond wave).
What is the impulse withstand (BIL) for the 15kV class?
For the 15kV voltage class, the impulse withstand (BIL) is 95kV (1.2 x 50 microsecond wave).
What is the maximum phase-to-ground operating voltage for 25kV class?
For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV.
What cable insulation diameters are compatible with K151SR?
The K151SR accommodates cable insulation diameters from .575 inches through 1.220 inches.
What cable conductor sizes can the K151SR accommodate?
The K151SR will accommodate conductor sizes from No. 4 solid through 4/0 stranded.
What is the continuous current rating for the K151SR?
The K151SR has a continuous current rating of 200 Amp for both 15kV and 25kV voltage classes.
What voltage systems is the K151SR suitable for?
The K151SR is suitable for use on both 15kV and 25kV systems.
What is included in a K151SR kit?
Each kit contains a straight receptacle housing, a receptacle pin connector, a tube of lubricant, installation instructions, and a crimp chart.
How to Install the K151SR/151SR Straight Receptacle
This guide provides detailed instructions for the safe and proper installation of the K151SR or 151SR straight receptacle, including cable preparation, crimping, assembly, and grounding procedures for high-voltage electrical systems.
Estimated time: 1h
Tools needed:
Wire strippers, Crimping tool, Wire brush, Rag
Supplies needed:
Conductor Contact (male), Nylon Venting Rod, Lubricant, Copper wire (#14 AWG or equivalent), Elastimold bail, Silicone grease, Approved solvent
- Perform Safety Checks and Component Inspection
Ensure all apparatus is de-energized before starting. This product must be installed by competent personnel trained in high-voltage safety practices. Inspect all components for damage, correct rating, and compatibility with mating parts. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors if the circuit will be submerged or energized before final connection. A bailing arrangement is required when this product is used with any mating Elastimold deadbreak product.
- Prepare Cable Jacket
Based on your cable type: For jacketed concentric neutral cable, cut and remove 8 inches of the cable jacket from the end, ensuring enough neutral wires for grounding. For copper tape shield cable, cut and remove 7 1/2 inches of the cable jacket, then remove the copper tape shield 6 1/2 inches from the end of the cable. Consult specific instructions for ECS or MA grounding devices if used.
- Prepare Conductor and Crimp Terminal
Remove 7/8 to 1 inch (or 1 3/4 to 1 7/8 inches for #1 stranded/compr. and #1/0 comp./solid aluminum cable) of cable insulation and conductive shield. Cut squarely, do not pencil. Wire brush bare aluminum conductors immediately, then insert them into the crimp barrel which contains inhibitor.
- Crimp Socket Terminal
Crimp the socket terminal onto the bared conductor, ensuring the conductor remains fully seated. Refer to the crimp chart (packed with contact) for specific instructions. Start crimps at the imprinted crimp line and rotate each successive crimp or indent 90 degrees. If using aluminum cable, carefully wipe any excess inhibitor from the contact and cable insulation.
- Prepare Semi-Conductive Shield and Clean Insulation
Remove the semi-conductive shield 7 9/16 to 7 5/8 inches back from the end of the pin with a straight, smooth, squared cut, taking care not to cut or nick the insulation. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation with a rag wet with an approved solvent, wiping from the cable end towards the outer jacket to remove all semi-conducting residue. Install ECS or MA grounding device if applicable.
- Lubricate and Insert Cable into Receptacle
Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Sparingly apply the supplied lubricant to the cable as indicated and to the inside of the housing. Do not substitute lubricants as they may be harmful. Push the cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle. If not connecting immediately, replace with an Elastimold insulating plug (K150DP) as the shipping cover is not an insulating device.
- Connect to Mating Plug
Lubricate the nose of the mating plug with silicone grease. Insert the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), ensuring it is not cut. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection using an Elastimold bail.
- Ground the Cable
If not using an ELASTIMOLD grounding device, connect a length of customer-supplied #14 AWG (or equivalent) copper wire through the grounding tab and twist tightly. Connect this grounding assembly to the system ground by merging it with the cable shield of each cable. Seal all grounding wires and connections to prevent corrosion.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.