ABB Installation Products K151SP-B2260 200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included…
UPC: 783786804726
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp continuous current rating for medium-voltage applications
- Compatible with 15kV and 25kV class systems
- Supports compressed stranded conductors from 3/0 to 4/0 AWG or 85.01 mm² solid
- Cable insulation diameter range: 0.635 inch to 0.905 inch
- Includes copper compression lug; bails required but sold separately
Specifications
Amperage Rating | 200 A |
Application | Designed to Terminate UD Cable having Concentric Neutral and Extruded instalation shielding |
Color | Black |
Conductor Range | 3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG |
Environmental Conditions | Fully Shielded, Fully Submersible |
Insulation | True |
Length | 8.81 in |
Length | 223.774 mm |
Material | Housing - EPDM-Rubber |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Straight Plug |
Voltage Rating | 15 to 25 kV |
Width | 2.55 in |
Width | 64.77 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

376LR-J-5260
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
K151SR-B0270
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid 250 or mmSquared 126.67.
273RLR-K-5240
200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
K151SP-B0270
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes an aluminum compression lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
274ELR-88110-5270
200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
K151SR-A0240
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49.
167RLR-K5240
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
168RLR-K-5260
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.Frequently Asked Questions
What are the key features of the K151SP?
It's a 15/25kV, 200 Amp Deadbreak Straight Plug with a fully shielded, submersible molded rubber housing. It features 100% peroxide-cured construction and a provision for ground wire connection.
What standard does the K151SP meet?
The K151SP meets ANSI/IEEE Standard 386, Latest Revision.
What is the impulse withstand rating for 25kV?
For the 25kV voltage class, the impulse withstand (BIL) is 125kV.
Are bails included with the K151SP?
No, bails are ordered separately and are required for the K151SP.
What type of conductors are copper compression lugs for?
Copper compression lugs are suitable for all copper conductors only.
What is the impulse withstand rating for 15kV?
For the 15kV voltage class, the impulse withstand (BIL) is 95kV.
What are the 25kV operating voltage limits?
For 25kV, the maximum phase-to-ground operating voltage is 15.2kV, and the maximum phase-to-phase is 26.3kV.
What is the continuous current rating?
The continuous current rating for both 15kV and 25kV voltage classes is 200 Amps.
What are the 15kV operating voltage limits?
For 15kV, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.
What products is the K151SP compatible with?
The K151SP is designed to mate with Elastimold® K151T tee splice and K151SR straight receptacle products.
How to Install the K151SP Straight Plug
This guide provides step-by-step instructions for preparing the cable and installing the K151SP Straight Plug, designed for connecting solid dielectric type cables on 15kV and 25kV class systems. Ensure all apparatus are de-energized before starting.
Estimated time: 1h
Tools needed:
Cable cutting tool, Cable stripping tool, Wire brush, Crimp tool, Rag
Supplies needed:
K151SP Straight Plug, Lubricant (supplied), Approved solvent, Silicone grease, ELASTIMOLD bail, #14 AWG copper wire (customer supplied, if needed)
- Prepare Cable Jacket
For Jacketed Concentric Neutral cable, cut and remove the cable jacket 8 inches from the cable end. Ensure sufficient concentric neutral wires are left for grounding. For Copper Tape Shield cable, cut and remove the cable jacket 7-1/2 inches from the cable end, then remove the copper tape shield 6-1/2 inches from the end of the cable. If using an ECS or MA grounding device, follow its specific instructions for outer jacket cut back.
- Prepare Cable Insulation and Conductor
Remove 7/8 inch to 1 inch of cable insulation and conductive shield. For #1 stranded/compressed and #1/0 compressed/solid aluminum cable, remove 1-3/4 inches to 1-7/8 inches. Cut squarely; do not pencil the cut. Wire brush bare aluminum conductors and immediately insert them into the crimp barrel, which contains inhibitor.
- Crimp Socket Terminal
Crimp the socket terminal onto the bared conductor, holding the crimp barrel against the cable insulation. Refer to the crimp chart provided with the contact. Start crimps at the crimp line imprinted on the barrel and rotate each successive crimp or indent 90 degrees. Carefully wipe any excess inhibitor from the contact and cable insulation.
- Prepare Semi-Conductive Shield and Insulation
Temporarily remove the plastic pin. Remove the semi-conductive shield to a point 7-3/4 inches to 7-13/16 inches back from the end of the socket with a straight, smooth, squared cut. Do not cut or nick the insulation. Replace the plastic pin. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation with an approved solvent to remove all traces of semi-conducting residue, wiping from the end of the cable toward the outer jacket. If using an ECS or MA grounding device, install it following its specific instructions.
- Lubricate Cable and Housing
Slide the collar, smaller end first, onto each cable. Refer to the bailing instruction sheet. Keep the cable insulation and plug clean. Apply the supplied lubricant sparingly to the cable as shown and to the inside of the housing. Do not substitute lubricants, as others may be harmful to the product.
- Install Plug onto Cable
Push the cable into the housing until the leading edge of the socket contact is flush with the front edge of the plug. Remove the plastic pin from the socket and discard it.
- Connect to Mating Receptacle
Lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1-3/4 inches), ensuring the rod is not cut. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with an ELASTIMOLD bail, referencing the Bailing Instruction Sheet (150TB-4).
- Connect Grounding
If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist tightly. Connect this grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.