ABB Installation Products K151SP-A0210 15/25kV 200 Amp, Deadbreak Straight Plug, Cable Insulation Diameter 0.575 inch to 0.740…
UPC: 075114403771
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25kV Voltage Rating
- 200 Amp Current Rating
- Deadbreak Straight Plug Configuration
- Accommodates 0.575" to 0.740" Cable Insulation Diameter
- Aluminum Compression Lug for Conductor Connection
Specifications
Amperage Rating | 200 A |
Application | Designed to Terminate UD Cable having Concentric Neutral and Extruded installation shielding |
Color | Black |
Conductor Range | #3 STR/COMPR AWG , #2 SOL/COMPT AWG |
Connection | Compression |
Connection Type | Compression Lug |
Current Rating | 200 A |
Environmental Conditions | Fully Shielded, Fully Submersible |
Insulation | True |
Length | 8.81 in |
Length | 223.774 mm |
Material | Aluminum |
Material | Housing - EPDM-Rubber |
Series | K151SP |
Size | Cable Insulation Diameter 0.575 inch to 0.740 inch |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Straight Plug |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 15/25 kV |
Width | 2.55 in |
Width | 64.77 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

274ELR-6689-5210
25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. No Sealing Kit
K151SR-A0210
15/25kV 200 Amp, Deadbreak Straight Receptacle, Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size #3 Compressed or Stranded AWG, or #2 Solid or Compact AWG or 26.67 mm2. Bails are required, but not included, order separately. Length 9.54 inch. Widest point 2.74 inch.
FTU 6 NAWR
Black PVC Coated Aluminum Flood Seal 125 Series Screw-on Transformer Connectors for Wire Size #12-500 kcmil, Stud size 5/8 inch, length 10-3/4 inch, Height 6-15/16 inch, Outlets 6. Bolt Holes per outlet is 2. Complete Assembly with Six CSN 2011 Insulating Rockets. Hardware included (12) 1/2-13 x 1 inch, and (1) 5/8-11 Steel Jam Nut.
SKB 1-6
Aluminum Keebar, Screw-on, Transformer Connector, Stud 1 Inch. 8-1/4 inch long x 2-53/64 inch tall. Stainless Steel Hardware includes (12) 1/2 inch Belleville Washers, (12) 1/2 inch Flat Washers, (12) 1/2-13 Nuts, (6) Studs. Cap and Grease. Pad is 8-1/4 inch long x 1-1/4 inch x 1/2 inch thick and has Six holes tapped 1/2-13 UNC-2B on 1-3/8 inch centers.
SL 210-6
Tin Plated Aluminum Mechanical Streetlight kit. Feeder 2/0 - #14, #14 - #6. Connector Length 1-15/64 inch x 3/4 inch x 1-1/8 inch. Includes (4) Screws - 5/16-24.
SLK 3 A
Aluminum Compression StreetLight Kit, Run #8-#6 Aluminum, Tap #8-#6 Aluminum. Includes Insulating Cap and Rocket, Wood Dowel, (2) Tin Plated Fuse Clips, Instruction Sheet and Silicone Grease.
SLK 6-8488
Flood Seal In Line Disconnect Kit, Single Housing. Includes Santoprene Insulating Cap and Rocket, Wood Dowel, (2) Tin Plated Copper Fuse Clips, (2) Copper Wire Stranded #14 x 19-3/4 inch, Silicone Grease.Frequently Asked Questions
What is the K151SP product type?
The K151SP is a 15/25kV, 200 Amp Deadbreak Straight Plug without a test point.
What is the maximum operating voltage for 15kV class?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.
What is included in the K151SP kit?
The kit includes a straight receptacle housing, a receptacle pin connector, lubricant, installation instructions, and a crimp chart.
Are bails included with the K151SP?
No, bails are ordered separately but are required for the K151SP.
What is the impulse withstand rating for 25kV?
For the 25kV voltage class, the impulse withstand (BIL) is 125kV.
What is the continuous current rating?
The continuous current rating for both 15kV and 25kV voltage classes is 200 Amps.
What is the maximum operating voltage for 25kV class?
For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV.
What ANSI/IEEE standard does it meet?
The K151SP meets ANSI/IEEE Standard 386, Latest Revision.
What products is the K151SP compatible with?
The K151SP is designed to mate with Elastimold® K151T tee splices and K151SR straight receptacles.
What cable insulation diameters are supported?
It supports cable insulation diameters ranging from .575 inches to 1.220 inches.
How to Install the K151SP Straight Plug
This guide provides step-by-step instructions for preparing the cable, assembling the K151SP Straight Plug, and connecting it to a mating receptacle for 15kV and 25kV class systems. Ensure all apparatus are de-energized before starting.
Estimated time: 1h 30m
Tools needed:
Cable cutting tool, Wire stripping tool, Wire brush, Crimping tool, Rag
Supplies needed:
K151SP Straight Plug kit (includes plug, conductor contact, nylon venting rod, lubricant), Solid dielectric type cable, Approved solvent, ELASTIMOLD bail, #14 AWG copper wire (if not using ELASTIMOLD grounding device), Sealing material (for grounding wires)
- De-energize and Prepare for Installation
DANGER: Ensure all electrical apparatus are de-energized before beginning installation or removal of any parts. Verify the system is de-energized using appropriate safety procedures and equipment. Inspect all K151SP components for damage, proper rating, and compatibility with the cable and mating products. Gather all required tools and supplies, maintaining a clean work area.
- Prepare Cable Jacket and Shield
For Jacketed Concentric Neutral cable: Cut and remove 8 inches of the cable jacket from the cable end. Ensure sufficient concentric neutral wires remain for connection to the ground point. For Copper Tape Shield cable: Cut and remove 7-1/2 inches of the cable jacket from the cable end. Then, remove 6-1/2 inches of the copper tape shield from the end of the cable. If using an ECS or MA grounding device, refer to its specific instructions for outer jacket cut back.
- Strip Cable Insulation and Conductive Shield
Remove 7/8 inch to 1 inch of cable insulation and conductive shield. For #1 stranded/compressed and #1/0 compressed/solid aluminum cable, remove 1-3/4 inches to 1-7/8 inches. Cut squarely; do not pencil the cut. Wire brush the bare aluminum conductors immediately and insert them into the crimp barrel, which contains an inhibitor.
- Crimp Socket Terminal
Crimp the socket terminal onto the bared conductor, holding the crimp barrel firmly against the cable insulation. Refer to the crimp chart provided with the contact for specific crimping instructions. Start crimps at the crimp line imprinted on the barrel and rotate each successive crimp or indent by 90 degrees. Carefully wipe any excess inhibitor from the contact and cable insulation.
- Prepare Semi-Conductive Shield and Insulation
Temporarily remove the plastic pin from the socket. Remove the semi-conductive shield to a point 7-3/4 inches to 7-13/16 inches back from the end of the socket using a straight, smooth, squared cut. Exercise extreme care to avoid cutting or nicking the cable insulation. Replace the plastic pin. Pencil the insulation 1/8 inch. Clean the outer jacket, and thoroughly clean the insulation to remove all traces of semi-conducting residue by wiping with a rag wet with an approved solvent. Always wipe from the end of the cable towards the outer jacket. If using an ECS or MA grounding device, install it now according to its specific instructions.
- Lubricate Cable and Install Collar
Slide the collar, smaller end first, onto each cable. Refer to the bailing instruction sheet for guidance. Keep the cable insulation and plug clean. Apply the supplied lubricant sparingly to the cable as shown in the documentation and to the inside of the housing. DO NOT SUBSTITUTE with other lubricants, as they may harm the product or its mating part.
- Push Cable into Housing
Push the prepared cable firmly into the housing until the leading edge of the socket contact is flush with the front edge of the plug. Remove the plastic pin from the socket and discard it.
- Connect to Mating Receptacle
Lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1-3/4 inches deep). Ensure the nylon rod is not cut during mating, which could leave material inside the interface. Insert the plug assembly into the receptacle as far as possible. Pull out and remove the nylon rod. Secure the electrical connection using an ELASTIMOLD bail. Refer to the Bailing Instruction Sheet (150TB-4) for proper installation of the bail.
- Ground the Connector
If an ELASTIMOLD grounding device is not being used, connect a length of customer-supplied #14 AWG (or equivalent) copper wire through the grounding tab and twist it tightly. Connect the grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal all grounding wires and connections to prevent corrosion and ensure long-term reliability.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.