Contact for Pricing
Overview
- 6-point junction assembly with multiple bushing interfaces
- Includes one 200 Amp Bushing Well Interface
- Features four 600 Amp Bushing Interfaces
- Additional one 200 Amp Bushing Well Interface
- Rated for 15kV operation
- Right parking stand for secure placement
- No tilt mounting capability
- Manufacturer: ABB - Installation Products
- SKU: J6-266662-15-R
Specifications
Application | Suited for Subsurface, Vault or Padmount Applications and can be used for Sectionalizing, Looping, Tapping and Equipment Bypass |
Connection | Push-In |
Connection Type | Bushing Well interface |
Current Rating | 200 A, 600 A |
Material | EPDM-Rubber and Stainless Steel Mounting Brackets |
Mounting | Right Parking Stand |
Mounting Type | No Tilt Mounting, Right Parking Stand |
Poles | 6 |
Size | Overall Length 28.5 inches, Width 6.75 inches |
Special Features | 4 inch Center Spacing. RightParking Stand |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Multi-Point Junction - 6 Points |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K650J3U
15/25kV 600 Series Deadbreak 3-Point Junction, Rubber Junction with stainless steel mounting plate, back plate and adjustable mounting bracket.
J5-26666-35-SV-L
5 Point Junction, with one 200 Amp Bushing Well Interfaces and four 600 Amp Bushing Interfaces, 35kV, Left Parking Stand. 6-1/2 inch Interface Spacing Centers
J5-22666-35
5 Point Junction, with two 200 Amp Bushing Well Interfaces and three 600 Amp Bushing Interfaces, 35kV
J6-222222-15L
15kV, 200/600 Amp Multipoint Junction. 6-Points, Six 200 Amp Bushing Well Interfaces, 15 kV, Standard 4 inch Spacing, Left Parking Stand Only
J6-222666-15L
15kV, 200/600 Amp Multipoint Junction. 6-Points, Three 200 Amp Bushing Well Interfaces, Three 600 Amp Bushing Interfaces, 15 kV, Standard 4 inch Spacing, Left Parking Stand Only
J6-622226-15L
15kV, 200/600 Amp Multipoint Junction. 6-Points, One 600 Amp Bushing Interface, Four 200 Amp Bushing Well Interfaces, One 600 Amp Bushing Interfaces, 15 kV, Standard 4 inch Spacing, Left Parking Stand Only
10EP-FB
200 Amp, 15/25kV, Deadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 0.675 inch to 0.785 inch. 9.25 inches Long. Plastic.
10EP-FG
15-35kV 200 Amp, Loadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 0.725 inch to 0.835 inch. 9.25 inches Long. Plastic.Frequently Asked Questions
What is the maximum operating voltage for 15kV class?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.
What is the AC one-minute withstand for 35kV class?
For the 35kV voltage class, the AC one-minute withstand rating is 50kV AC.
What are the typical applications for these junctions?
They are designed for subsurface, vault, or padmount applications, used for sectionalizing, looping, tapping, and equipment bypass.
What is the impulse withstand for 25kV class?
The 25kV voltage class has a 140kV BIL (Basic Impulse Level) impulse withstand rating.
What is the continuous current rating?
The continuous current rating is either 200 Amp or 600 Amp, depending on the chosen interface.
What are the voltage and current ratings?
The junctions are rated for 15/25/35kV voltage classes and either 200 Amp or 600 Amp continuous current.
What is the momentary fault close rating for 600 Amp?
For 600 Amp interfaces, the momentary and fault close rating is 25kA Symmetrical for 10 cycles.
What items are included in the product kit?
Each kit contains a basic molded junction, mounting hardware, lubricant, installation instructions, and a protective cap.
What are the voltage and current ratings?
The junctions are rated for 15/25/35kV voltage classes and either 200 Amp or 600 Amp continuous current.
What is the AC one-minute withstand for 35kV class?
For the 35kV voltage class, the AC one-minute withstand rating is 50kV AC.
How to Install J6-266662-15-R Deadbreak Junctions (Universal Mount)
This guide provides step-by-step instructions for installing the J6-266662-15-R Deadbreak Junctions using the Universal Mount method, designed for sectionalizing, looping, tapping, or apparatus change out. Ensure all apparatus is de-energized before beginning installation.
Estimated time: 1h
Tools needed:
Wrench, Screwdriver, Wire strippers
Supplies needed:
Suitable fasteners, Grounding wire (No. 2 solid to 1/0 stranded), ELASTIMOLD approved lubricant, HV insulated caps (if needed)
- Prepare Mounting Location and Mark Slots
DANGER: All apparatus must be de-energized during installation. This product must be installed by competent personnel trained in high voltage electrical safety practices. Determine the desired location for the junction assembly. Using the base plate as a template, place it on the mounting surface and mark the slot locations for drilling or fastener placement.
- Attach Initial Universal Brackets
Attach two universal brackets to the marked slot locations on the flat surface using suitable fasteners. Tighten securely to prevent any movement during operation.
- Assemble Remaining Universal Brackets
Attach the remaining two universal brackets to the two brackets already mounted on the surface at the desired angle using the supplied 3/8” hex head cap screws, external tooth lock washers, and 3/8” hex nuts. Tighten securely.
- Assemble Junction to Base Bracket and Base Plate
Assemble the deadbreak junction to the base bracket assembly and base plate. Use two 1/2” hex head cap screws, two 1/2” split lock washers, and two 1/2” hex nuts, attaching them to the center mounting holes on the bracket assembly. Tighten securely.
- Attach Junction Assembly to Universal Brackets
Attach the complete deadbreak junction assembly to the previously mounted universal brackets using the supplied 1/2” hex head cap screws, 1/2” split lock washers, and 1/2” hex nuts. Ensure the parking stand is in the upright position and tighten all hardware securely.
- Ground the Assembly
Ground the base bracket assembly and the junction’s black conductive jacket. Connect a grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket. Ensure a secure and reliable ground connection.
- Prepare for Operation
Remove all protective shipping caps and clean the operating interfaces. Lubricate each interface with an ELASTIMOLD approved lubricant. If not all operating interfaces are utilized, install appropriate HV insulated caps on unused bushings before energization. Do not use shipping caps for this purpose.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.