Overview
- 35kV voltage rating for medium-voltage applications
- Two 200 Amp bushing well interfaces
- Three 600 Amp bushing interfaces
- Facilitates efficient power distribution and branching
- ABB - Installation Products manufacturer
Specifications
Application | Suited for Subsurface, Vault or Padmount Applications and can be used for Sectionalizing, Looping, Tapping and Equipment Bypass |
Connection | Push-In |
Connection Type | Bushing Interface |
Current Rating | 200 A, 600 A |
Material | EPDM-Rubber and Stainless Steel Mounting Brackets |
Mounting | No Parking Stand |
Poles | 5 |
Size | Overall Length 27 inches, Width 6-3/4 inches |
Special Features | 4 inch Center Spacing |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Multi-Point Junction - 5 Points |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

J4-2266-35-N
4 Point Junction, with two 200 Amp Bushing Well Interfaces and two 600 Amp Bushing interfaces, 35kV, No Parking Stand.
J6-222222-15L
15kV, 200/600 Amp Multipoint Junction. 6-Points, Six 200 Amp Bushing Well Interfaces, 15 kV, Standard 4 inch Spacing, Left Parking Stand Only
J6-222666-15L
15kV, 200/600 Amp Multipoint Junction. 6-Points, Three 200 Amp Bushing Well Interfaces, Three 600 Amp Bushing Interfaces, 15 kV, Standard 4 inch Spacing, Left Parking Stand Only
J6-622226-15L
15kV, 200/600 Amp Multipoint Junction. 6-Points, One 600 Amp Bushing Interface, Four 200 Amp Bushing Well Interfaces, One 600 Amp Bushing Interfaces, 15 kV, Standard 4 inch Spacing, Left Parking Stand Only
10EP-FB
200 Amp, 15/25kV, Deadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 0.675 inch to 0.785 inch. 9.25 inches Long. Plastic.
10EP-FG
15-35kV 200 Amp, Loadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 0.725 inch to 0.835 inch. 9.25 inches Long. Plastic.
10EP-HAB
200 Amp, 15/25kV, Deadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 1.040 inch to 1.175 inch. 9.25 inches Long. Plastic.
00700270
Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size 4/0 - Stranded/Compressed, 250 Compact/SolidFrequently Asked Questions
What is the corona extinction voltage for a 15kV junction?
For the 15kV voltage class, the corona extinction voltage is 11kV AC at 3pC sensitivity.
What is the fault close rating for a 200 Amp junction?
A 200 Amp junction has a 10kA Sym – 10 Cycles Momentary & Fault Close rating.
How many points can a junction have?
The junctions are available with 2, 3, 4, 5, or 6 points.
What is included in a standard junction kit?
Each kit contains a basic molded junction, mounting hardware, two tubes of lubricant, installation instructions, and a protective cap.
What types of interfaces can be selected?
Customers can select any combination of 200 Amp deepwell or 600 Amp bushing interfaces.
What standards do these junctions meet?
The multipoint junctions meet ANSI/IEEE Standard 386, Latest Revision.
What materials are used for the housing and brackets?
The junctions feature a fully shielded, submersible molded rubber housing and utilize 304 stainless steel for brackets to prevent rusting.
What connectors are compatible with these junctions?
These junctions provide mating for Elastimold Elbow connectors, both 600 Amp and 200 Amp.
What applications are suitable for these junctions?
ELASTIMOLD junctions are designed for subsurface, vault, or padmount applications, used for sectionalizing, looping, tapping, and equipment bypass.
What are the voltage classes for these junctions?
The multipoint junctions are available in 15kV, 25kV, and 35kV voltage classes.
How to Install the J5-22666-35 Deadbreak Junction (Universal Mount)
This guide provides step-by-step instructions for installing the J5-22666-35 deadbreak junction using the universal mount configuration. It covers mounting, assembly, and grounding procedures for sectionalizing, looping, or tapping electrical systems.
Estimated time: 1h
Tools needed:
Wrench, Wire Strippers, Drill (if needed for surface fasteners)
Supplies needed:
J5-22666-35 Deadbreak Junction, Base Bracket, Base Plate, Universal Brackets (4), Mounting Hardware Prepack (including 3/8 inch and 1/2 inch hex head cap screws, hex nuts, and lock washers), Suitable Fasteners (for mounting to surface, user-supplied), Grounding Wire (No. 2 solid to 1/0 stranded), HV Insulated Caps or Connectors (if interfaces unused), ELASTIMOLD Approved Lubricant
- De-energize and Prepare Site
DANGER: Ensure all apparatus are de-energized before beginning installation. Verify the desired location for the junction assembly. Use the base plate as a template to mark the slot locations on the mounting surface for the universal brackets.
- Mount Initial Universal Brackets
Attach two universal brackets to the marked slot locations on the flat surface using suitable fasteners. Tighten them securely to prevent any movement during operation.
- Attach Remaining Universal Brackets
Connect the remaining two universal brackets to the two brackets already mounted on the surface at the desired angle. Use the supplied 3/8 inch hex head cap screws, external tooth lock washers, and 3/8 inch hex nuts. Tighten securely.
- Assemble Junction to Base Bracket and Plate
Assemble the deadbreak junction to the base bracket assembly and base plate. Use two 1/2 inch hex head cap screws, two 1/2 inch split lock washers, and two 1/2 inch hex nuts, attaching them to the center mounting holes on the bracket assembly. Tighten securely.
- Attach Junction Assembly to Universal Brackets
Attach the assembled deadbreak junction to the universal brackets using the supplied 1/2 inch hex head cap screws, 1/2 inch split lock washers, and 1/2 inch hex nuts. Ensure the parking stand is in the upright position and tighten all hardware securely.
- Ground the Assembly
Ground the base bracket assembly and the junction's black conductive jacket. Connect a grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket for this purpose.
- Prepare for Operation
Remove all protective shipping caps and clean the operating interfaces. Lubricate each interface with an ELASTIMOLD approved lubricant; do not substitute. If any operating interfaces are not utilized, install appropriate HV insulated caps or connectors on the unused bushing(s) before energizing the circuit. Do not use protective shipping caps for this function as they are not insulated.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.