ABB - Installation Products 10EP-FB - 200 Amp, 15/25kV, Deadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 0.675 inch to 0.785 inch. 9.25 inches Long. Plastic.

ABB Installation Products 10EP-FB 200 Amp, 15/25kV, Deadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation…

UPC: 783786427994


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 10EP-FB is a Deadbreak Elbow Cable Entrance Insulating Plug designed for reliable electrical connections in medium-voltage systems. This plug is rated for 200 Amps and operates within a 15/25kV voltage class, making it suitable for a range of industrial and utility applications. Its construction utilizes durable plastic material for longevity and effective insulation. The design accommodates cable insulation diameters ranging from 0.675 inches to 0.785 inches, ensuring a secure fit for specified cable sizes. With a length of 9.25 inches, this insulating plug provides adequate clearance and protection for the cable entrance. The ABB 10EP-FB, SKU 10EP-FB, is manufactured by ABB - Installation Products, a recognized name in electrical infrastructure components. This component is essential for creating safe and effective deadbreak connections, preventing electrical discharge and ensuring system integrity. Its specific dimensions and electrical ratings are critical for proper application in power distribution networks and industrial facilities requiring robust cable termination solutions. The UNSPSC code for this product is 26121630.
  • 200 Amp current rating
  • 15/25kV voltage class
  • Accommodates cable insulation diameter 0.675" to 0.785"
  • Durable plastic construction
  • 9.25 inches overall length

Specifications

Application
Holds Elbow in Place and Seals Cable Entrances
Connection
Threaded
Material
Plastic
Size
Cable Insulation Diameter 0.675 inch to 0.785 inch
Special Features
Non-Electrical. Fake Probe
Type
Plastic Insulating Plug
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15/25kV, 900 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Boot and Collar.

K675TBC

15/25kV, 900 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Boot and Collar.
Sealing Cap, Black, Thermoplastic, AMP CPC

208652-1

Sealing Cap, Black, Thermoplastic, AMP CPC
15-35kV 200 Amp, Loadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 0.725 inch to 0.835 inch. 9.25 inches Long. Plastic.

10EP-FG

15-35kV 200 Amp, Loadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 0.725 inch to 0.835 inch. 9.25 inches Long. Plastic.
200 Amp, 15/25kV, Deadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 1.040 inch to 1.175 inch. 9.25 inches Long. Plastic.

10EP-HAB

200 Amp, 15/25kV, Deadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 1.040 inch to 1.175 inch. 9.25 inches Long. Plastic.
Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size 4/0 - Stranded/Compressed, 250 Compact/Solid

00700270

Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size 4/0 - Stranded/Compressed, 250 Compact/Solid
Gray, Single Piece Terminator (Class 1) includes Contract Rod, Ground Strap and Rain Cap. 15/25kv, Cable Insulation Diameter .675 to .785 inches, Conductor size - #2 Stranded/Compressed or #1 Compact/Solid.

16THG-FB-0220-4

Gray, Single Piece Terminator (Class 1) includes Contract Rod, Ground Strap and Rain Cap. 15/25kv, Cable Insulation Diameter .675 to .785 inches, Conductor size - #2 Stranded/Compressed or #1 Compact/Solid.
Gray, Single Piece Terminator (Class 1) includes Contract Rod, Ground Strap and Rain Cap. 15/25kv, Cable Insulation Diameter .875 to .985 inches, Conductor size - 1/0 Stranded/Compressed or 2/0 Compact/Solid. For Aluminum Only

16THG-GB-1240-4

Gray, Single Piece Terminator (Class 1) includes Contract Rod, Ground Strap and Rain Cap. 15/25kv, Cable Insulation Diameter .875 to .985 inches, Conductor size - 1/0 Stranded/Compressed or 2/0 Compact/Solid. For Aluminum Only
15-35kV 200 Amp, Loadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 0.875 inch to 0.985 inch. 9.25 inches Long. Plastic.

10EP-GB

15-35kV 200 Amp, Loadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 0.875 inch to 0.985 inch. 9.25 inches Long. Plastic.

Frequently Asked Questions

What is the cable insulation diameter range for the FB size?

For the FB size, the cable insulation diameter ranges from 0.675 inches minimum to 0.785 inches maximum.

Which Elastimold® elbow cable entrance sizes are compatible with the 10EP plug?

The 10EP plug is available for Elastimold® elbow cable entrance sizes EB, EF, FA, FAB, FB, FG, GA, GAB, and GB.

How is an elbow connector's normal function restored after using the 10EP?

The normal function is restored by removing the 10EP and replacing it with a properly prepared cable.

What components are included in the 10EPW kit?

Each kit contains one Insulated Plug 10EP, one Crimp Chart IS-0169, and one Lubricant 82-08.

What is the 10EP plug's primary design purpose?

It is designed to electrically insulate and water seal the cable entrances of Elastimold® 200 Amp elbow connectors.

What components are included in the 10EPW kit?

Each kit contains one Insulated Plug 10EP, one Crimp Chart IS-0169, and one Lubricant 82-08.

What is the cable insulation diameter range for the FB size?

For the FB size, the cable insulation diameter ranges from 0.675 inches minimum to 0.785 inches maximum.

Which Elastimold® elbow cable entrance sizes are compatible with the 10EP plug?

The 10EP plug is available for Elastimold® elbow cable entrance sizes EB, EF, FA, FAB, FB, FG, GA, GAB, and GB.

How is an elbow connector's normal function restored after using the 10EP?

The normal function is restored by removing the 10EP and replacing it with a properly prepared cable.

What is the 10EP plug's primary design purpose?

It is designed to electrically insulate and water seal the cable entrances of Elastimold® 200 Amp elbow connectors.

How to Install the 10EP Elbow Cable Entrance Insulating Plug

This guide provides step-by-step instructions for safely installing the 10EP Elbow Cable Entrance Insulating Plug onto an Elastimold 200amp Deadbreak or Loadbreak elbow, including initial setup and voltage testing.

Estimated time: 30m

Tools needed:

Pliers, Hotstick, Suitable capacitive sensing device

Supplies needed:

10EP Elbow Cable Entrance Insulating Plug, Lubricant (supplied or ELASTIMOLD® approved), Male contact, Protective cap (for male contact threads), Wire (No. 14 AWG copper equivalent, for grounding), Test point cap, Silicone grease

  1. Perform Pre-Installation Safety and Inspection

    Before beginning, ensure all apparatus is de-energized. Inspect all parts for damage, proper rating, and compatibility with mating products. Have all required tools at hand and maintain cleanliness throughout the procedure. This product must be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment.

  2. Lubricate the Insulating Plug

    Lightly lubricate the surface of the insulating plug with the supplied lubricant or ELASTIMOLD® approved lubricant for a distance of approximately 4-1/2 inches from the second chamfered step. DO NOT SUBSTITUTE other lubricants, as they may be harmful to this product or its mating product(s).

  3. Position and Insert the Insulating Plug

    Position the insulating plug so its flat contact area faces the receptacle end of the elbow connector. Slide the 10EP into the elbow connector until it cannot advance any further. Look into the receptacle end of the elbow to verify if the threaded hole in the 10EP is properly positioned to accept the male contact. If it is not, use pliers on the exposed end of the 10EP to turn it into position.

  4. Install the Male Contact

    Remove the protective cap from the threads of the male contact. Insert the threaded end of the male contact into the threaded hole of the insulating plug, which is located in the receptacle end of the elbow. Hand tighten this contact. SNUG TIGHTEN ONLY TO AVOID STRIPPING THREADS; do not tighten until the wrench bends as indicated in the elbow connector instructions.

  5. Complete Elbow Assembly and Grounding

    Lightly lubricate both the bushing and elbow connector mating surfaces. Complete the assembly as indicated in the instructions for the elbow. Elbows using the 10EP must be grounded by connecting a piece of wire equivalent to No. 14 AWG (2.5mm²) copper from the apparatus ground to the elbow grounding eye.

  6. Perform Voltage Test (Optional)

    If performing a voltage test, first remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line with the test point assembly. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the specific meter used. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means, as contamination or incorrect equipment can provide false readings.

  7. Replace Test Point Cap

    After voltage detection has been made, clean and lubricate the inside surface of the test point cap with silicone grease. Replace the cap firmly on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.