ABB - Installation Products 10EP-FG - 15-35kV 200 Amp, Loadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 0.725 inch to 0.835 inch. 9.25 inches Long. Plastic.

ABB Installation Products 10EP-FG 15-35kV 200 Amp, Loadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation…

UPC: 783786620715


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 125

Multiplier: 125

*Contact for lower quantities*

Call (262) 252-1600 or email [email protected] for pricing and availability.

Overview

The ABB 10EP-FG is a 15-35kV, 200 Amp loadbreak elbow cable entrance insulating plug designed for medium-voltage cable systems. This plug accommodates cable insulation diameters between 0.725 inch and 0.835 inch, ensuring compatibility with a range of standard cable sizes. Measuring 9.25 inches in length, the unit is constructed from durable plastic, providing reliable electrical insulation and mechanical protection in outdoor and indoor applications. This loadbreak elbow plug is engineered for safe, hot-stick operable connections in pad-mounted transformers, switchgear, and underground distribution systems. It enables quick, loadbreak switching of cable circuits without de-energizing the entire system, reducing downtime during maintenance or reconfiguration. The insulating design prevents phase-to-phase or phase-to-ground faults during installation and removal, meeting ANSI/IEEE C119.4 standards for loadbreak connectors. Common applications include utility substations, commercial and industrial power distribution, and renewable energy installations where medium-voltage cable terminations require frequent access. The ABB 10EP-FG is part of a complete line of loadbreak accessories, ensuring system compatibility and long-term reliability in harsh environmental conditions.
  • Rated for 15-35kV, 200 Amp medium-voltage applications
  • Accommodates cable insulation diameters from 0.725" to 0.835"
  • 9.25" length with durable plastic construction
  • Loadbreak design enables hot-stick operation and safe circuit switching
  • Meets ANSI/IEEE C119.4 standards for loadbreak connectors

Specifications

Application
Holds Elbow in Place and Seals Cable Entrances
Connection
Threaded
Connection Type
Loadbreak Elbow
Current Rating
200 A
Material
Plastic
Series
10EP
Size
Cable Insulation Diameter 0.725 inch to 0.835 inch
Size
0.725 inch to 0.835 inch (Cable Insulation Diameter), 9.25 inches (Length)
Special Features
Non-Electrical. Fake Probe
Type
Plastic Insulating Plug
Voltage Rating
15-35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.1600 L
Package Weight (Metric)
0.0730 kg
15/25kV, 900 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Boot and Collar.

K675TBC

15/25kV, 900 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Boot and Collar.
Sealing Cap, Black, Thermoplastic, AMP CPC

208652-1

Sealing Cap, Black, Thermoplastic, AMP CPC
200 Amp, 15/25kV, Deadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 1.040 inch to 1.175 inch. 9.25 inches Long. Plastic.

10EP-HAB

200 Amp, 15/25kV, Deadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 1.040 inch to 1.175 inch. 9.25 inches Long. Plastic.
Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size 4/0 - Stranded/Compressed, 250 Compact/Solid

00700270

Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size 4/0 - Stranded/Compressed, 250 Compact/Solid
Gray, Single Piece Terminator (Class 1) includes Contract Rod, Ground Strap and Rain Cap. 15/25kv, Cable Insulation Diameter .675 to .785 inches, Conductor size - #2 Stranded/Compressed or #1 Compact/Solid.

16THG-FB-0220-4

Gray, Single Piece Terminator (Class 1) includes Contract Rod, Ground Strap and Rain Cap. 15/25kv, Cable Insulation Diameter .675 to .785 inches, Conductor size - #2 Stranded/Compressed or #1 Compact/Solid.
Gray, Single Piece Terminator (Class 1) includes Contract Rod, Ground Strap and Rain Cap. 15/25kv, Cable Insulation Diameter .875 to .985 inches, Conductor size - 1/0 Stranded/Compressed or 2/0 Compact/Solid. For Aluminum Only

16THG-GB-1240-4

Gray, Single Piece Terminator (Class 1) includes Contract Rod, Ground Strap and Rain Cap. 15/25kv, Cable Insulation Diameter .875 to .985 inches, Conductor size - 1/0 Stranded/Compressed or 2/0 Compact/Solid. For Aluminum Only
15-35kV 200 Amp, Loadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 0.875 inch to 0.985 inch. 9.25 inches Long. Plastic.

10EP-GB

15-35kV 200 Amp, Loadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 0.875 inch to 0.985 inch. 9.25 inches Long. Plastic.
Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size 1/0 - Stranded/Compressed, 2/0 Compact/Solid

00700240

Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size 1/0 - Stranded/Compressed, 2/0 Compact/Solid

Frequently Asked Questions

What is the primary function of the 10EP insulating plug?

The 10EP insulating plug is designed to electrically insulate and water seal the cable entrances of Elastimold® 200 Amp elbow connectors. It provides an electrically and mechanically sound dead-end cable entrance.

What items are included in the 10EP kit?

Each kit contains one Insulated Plug 10EP, one Crimp Chart IS-0169, and one Lubricant 82-08.

What cable insulation diameter range does 10EP-FG support?

The 10EP-FG is compatible with cable insulation diameters ranging from 0.725 in to 0.835 in.

How is the normal function of an elbow connector restored after using 10EP?

The normal function of the elbow connector is restored by simply removing the 10EP and replacing it with a properly prepared cable.

What Elastimold elbow cable entrance sizes are available for the 10EP?

The 10EP is available for Elastimold® elbow cable entrance sizes EB, EF, FA, FAB, FB, FG, GA, GAB, and GB.

What is the primary function of the 10EP insulating plug?

The 10EP insulating plug is designed to electrically insulate and water seal the cable entrances of Elastimold® 200 Amp elbow connectors. It provides an electrically and mechanically sound dead-end cable entrance.

What items are included in the 10EP kit?

Each kit contains one Insulated Plug 10EP, one Crimp Chart IS-0169, and one Lubricant 82-08.

What cable insulation diameter range does 10EP-FG support?

The 10EP-FG is compatible with cable insulation diameters ranging from 0.725 in to 0.835 in.

How is the normal function of an elbow connector restored after using 10EP?

The normal function of the elbow connector is restored by simply removing the 10EP and replacing it with a properly prepared cable.

What Elastimold elbow cable entrance sizes are available for the 10EP?

The 10EP is available for Elastimold® elbow cable entrance sizes EB, EF, FA, FAB, FB, FG, GA, GAB, and GB.

How to Install the 10EP Elbow Cable Entrance Insulating Plug

This guide provides step-by-step instructions for safely installing the 10EP Elbow Cable Entrance Insulating Plug onto an Elastimold 200amp Deadbreak or Loadbreak elbow, including initial setup and voltage testing.

Estimated time: 30m

Tools needed:

Pliers, Hotstick, Suitable sensing device for capacitive test points

Supplies needed:

10EP Elbow Cable Entrance Insulating Plug, Lubricant (supplied or ELASTIMOLD approved), Elastimold 200amp Deadbreak or Loadbreak elbow, Male contact, Protective cap for male contact, Silicone grease, No. 14 AWG (2,5mm2) copper wire

  1. Prepare for Installation and Ensure Safety

    De-energize all apparatus before installation or removal. Inspect all parts (insulating plug, elbow, male contact) for damage, correct rating, and compatibility with mating parts. Ensure all required tools and supplies are at hand. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors if supplied. WARNING: Do not touch or move energized products in the work area. This product should only be installed by competent personnel trained in good safety practices involving high voltage electrical equipment.

  2. Lubricate the Insulating Plug

    Lightly lubricate the surface of the insulating plug with the supplied lubricant or ELASTIMOLD approved lubricant for approximately 4-1/2 inches (11.4 cm) from the second chamfered step. DO NOT SUBSTITUTE, as other lubricants may be harmful to this product or its mating product(s).

  3. Position and Insert the Insulating Plug

    Position the insulating plug so its flat contact area faces the receptacle end of the elbow connector. Slide the 10EP into the elbow connector until it cannot advance further. Look into the receptacle end of the elbow to verify if the threaded hole in the 10EP is correctly positioned to accept the male contact. If not, use pliers on the exposed end of the 10EP to turn it into position.

  4. Install and Tighten the Male Contact

    Remove the protective cap from the threads of the male contact. Insert the threaded end of the male contact into the threaded hole of the insulating plug, located in the receptacle end of the elbow. Hand tighten this contact. SNUG TIGHTEN ONLY to avoid stripping threads; do not tighten until the wrench bends as indicated in the elbow connector instructions.

  5. Complete Elbow Assembly and Grounding

    Lightly lubricate both the bushing and elbow connector mating surfaces. Complete the assembly as indicated in the instructions for the elbow. Ground the elbow by connecting a piece of wire equivalent to No. 14 AWG (2,5mm2) copper from the apparatus ground to the elbow grounding eye.

  6. Perform Voltage Test (Optional Verification)

    WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. SAFETY WARNING: Contamination, moisture, dirt, or using the wrong measuring equipment can provide a false 'no voltage' indication. Treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means to prevent serious or fatal injury. After voltage detection, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.