Authorized ABB Distributor (Installation Products)
ABB - Installation Products J4-6266-15 - 4 Point Junction, with one 600 Amp Bushing Interface, one 200 Amp Bushing Well interface and two 600 Amp Bushing Interfaces, 15kV, No Tilt Mounting.

ABB Installation Products J4-6266-15 4 Point Junction, with one 600 Amp Bushing Interface, one 200 Amp Bushing Well interface…

UPC: 783786554584


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Installation Products J4-6266-15 is a 4-point molded multipoint junction designed for medium-voltage electrical systems at 15kV. This unit features one 600 Amp bushing interface, one 200 Amp bushing well interface, and two additional 600 Amp bushing interfaces, providing flexible connection options for distribution networks. The no-tilt mounting design simplifies installation in confined spaces or where angular mounting is impractical. Built for reliability in industrial and utility applications, the J4-6266-15 supports substations, switchgear, and power distribution systems. The 15kV rating ensures compatibility with standard medium-voltage infrastructure, while the multiple bushing interfaces allow for parallel or redundant connections. The compact form factor supports efficient use of panel space without sacrificing current capacity. Key applications include secondary distribution networks, industrial power feeds, utility substation tie-ins, and renewable energy integration points. The junction meets ANSI/IEEE Standard 386, with a maximum phase-to-ground operating voltage of 8.3kV and a BIL (Basic Impulse Level) of 95kV. It features a fully shielded, fully submersible molded rubber housing with 100% peroxide-cured insulation and conductive EPDM materials. The 304 stainless steel brackets prevent rusting and corrosion, ensuring long-term durability in harsh environments. The J4-6266-15 is part of ABB’s J4 series, offering modular design flexibility for selecting combinations of 200A deepwell or 600A bushing interfaces with 4-inch or 6.5-inch spacing. This junction is ideal for sectionalizing, looping, tapping, and equipment bypass in subsurface, vault, or padmount applications. For systems requiring scalable, high-current interconnections at 15kV, the J4-6266-15 delivers proven performance with ABB’s engineering standards.
  • 15kV Voltage Class with 8.3kV Max Phase-to-Ground Operating Voltage
  • Features one 200 Amp Bushing Well Interface and three 600 Amp Bushing Interfaces
  • Fully shielded, fully submersible molded rubber housing for durability
  • 304 stainless steel brackets for rust and corrosion prevention
  • Designed for subsurface, vault, or padmount applications

Specifications

Application
Suited for Subsurface, Vault or Padmount Applications and can be used for Sectionalizing, Looping, Tapping and Equipment Bypass
Connection
Push-In
Connection Type
Bushing Interface
Current Rating
600A/200A/600A/600A
Material
EPDM-Rubber and Stainless Steel Mounting Brackets
Mounting
No Tilt Mounting Bracket
Mounting Type
No Tilt Mounting
Poles
4P
Series
J4-6266
Size
Overall Length 23 inches, Width 6-3/4 inches
Special Features
4 inch Center Spacing
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Multi-Point Junction - 4 Points
Voltage Rating
15kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 15kV, Left Parking Stand.

J4-6226-15-L

4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 15kV, Left Parking Stand.
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 25kV, 6-1/2 inch centers. No Tilt Mounting.

J4-6226-25-SV-N

4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 25kV, 6-1/2 inch centers. No Tilt Mounting.
4 Point Junction, with one 600 Amp Bushing Interface, one 200 Amp Bushing Well interface and two 600 Amp Bushing Interfaces, 15kV, No Parking Stand.

J4-6266-15-N

4 Point Junction, with one 600 Amp Bushing Interface, one 200 Amp Bushing Well interface and two 600 Amp Bushing Interfaces, 15kV, No Parking Stand.
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 25kV, Tilt Mounting Adapter.

J4-6226-25-TMA

4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 25kV, Tilt Mounting Adapter.
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 35kV, Tilt Mounting Adapter.

J4-6226-35-TMA

4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 35kV, Tilt Mounting Adapter.
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 35kV, No Tilt Mounting.

J4-6226-35

4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 35kV, No Tilt Mounting.
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 25kV, No Tilt Mounting.

J4-6226-25

4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 25kV, No Tilt Mounting.
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 25kV, Right Parking Stand.

J4-6226-25-R

4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 25kV, Right Parking Stand.

Frequently Asked Questions

What industry standards do these junctions meet?

The junctions meet ANSI/IEEE Standard 386, Latest Revision.

What interface options and spacing are available?

Units offer 200A deepwell or 600A bushing interfaces with modular design flexibility. Spacing options are standard 4'' or optional 6.5''.

What connectors are compatible with these junctions?

The junctions provide mating for Elastimold Elbow connectors, both 600 Amp and 200 Amp.

What are the momentary and fault close ratings?

For 600 Amp, it's 25kA Sym for 10 cycles. For 200 Amp, it's 10kA Sym for 10 cycles.

What are the continuous current ratings?

The junctions have continuous current ratings of either 600 Amp or 200 Amp.

What are the maximum operating voltages for each class?

Max phase-to-ground operating voltages are 8.3kV for 15kV class, 16.2kV for 25kV class, and 21.1kV for 35kV class.

What voltage classes are available for the junctions?

The junctions are available in 15kV, 25kV, and 35kV voltage classes.

What connectors are compatible with these junctions?

The junctions provide mating for Elastimold Elbow connectors, both 600 Amp and 200 Amp.

What voltage classes are available for the junctions?

The junctions are available in 15kV, 25kV, and 35kV voltage classes.

What are the maximum operating voltages for each class?

Max phase-to-ground operating voltages are 8.3kV for 15kV class, 16.2kV for 25kV class, and 21.1kV for 35kV class.

How to Install the J4-6266-15 Deadbreak Junction (Universal Mount)

This guide provides step-by-step instructions for the safe installation and initial setup of the J4-6266-15 Two-, Three-, or Four-Point Deadbreak Junction using the Universal Mount method. It covers mounting, assembly, grounding, and preparing operating interfaces.

Estimated time: 45m

Tools needed:

Wrenches (for 3/8" and 1/2" hex nuts/screws), Wire Strippers, Crimping Tool, Multimeter

Supplies needed:

Suitable Fasteners (for mounting brackets to surface), Grounding Wire (No. 2 solid to 1/0 stranded), ELASTIMOLD Approved Lubricant, HV Insulated Caps (for unused bushings, if applicable), 3/8" Hex Head Cap Screws, External Tooth Lock Washers, 3/8" Hex Nuts, 1/2" Hex Head Cap Screws, 1/2" Split Lock Washers, 1/2" Hex Nuts

  1. Ensure De-energization and Safety

    Verify that all apparatus is de-energized before beginning installation or removal of any parts. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. Failure to follow these instructions may result in serious injury or death.

  2. Determine Mounting Location and Mark

    Select the desired location for the junction assembly. Use the base plate as a template, position it on the mounting surface, and accurately mark all slot locations for drilling or fastener placement.

  3. Attach Initial Universal Brackets

    Secure two (2) universal brackets to the marked flat surface using suitable fasteners. Tighten these fasteners securely to prevent any movement of the brackets during operation.

  4. Assemble Remaining Universal Brackets

    Attach the remaining two (2) universal brackets to the two brackets already mounted on the surface. Position them at the desired angle and secure them using the supplied 3/8” hex head cap screws, external tooth lock washers, and 3/8” hex nuts. Tighten securely.

  5. Assemble Junction to Base Bracket and Plate

    Connect the deadbreak junction to the base bracket assembly and base plate. Use two (2) 1/2” hex head cap screws, two (2) 1/2” split lock washers, and two (2) 1/2” hex nuts, attaching them to the center mounting holes on the bracket assembly. Ensure all connections are tightened securely.

  6. Mount Junction Assembly to Universal Brackets

    Attach the complete deadbreak junction assembly to the universal brackets using the supplied 1/2” hex head cap screws, 1/2” split lock washers, and 1/2” hex nuts. Tighten all hardware securely and ensure the parking stand is in the upright position.

  7. Ground the Assembly

    Ground the base bracket assembly and the junction’s black conductive jacket. Connect a grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket and ensure it is securely fastened to an earth ground.

  8. Prepare Operating Interfaces

    Remove all protective shipping caps from the operating interfaces and thoroughly clean them. Lubricate each interface with an ELASTIMOLD approved lubricant. Do not use substitute lubricants, as they may damage the product.

  9. Install Insulated Caps (if necessary)

    If any operating interfaces are not utilized, install appropriate HV insulated caps on these unused bushings before energizing the circuit. Do not use the protective shipping caps for this purpose, as they are not insulated.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.