ABB - Installation Products J4-6226-25 - 4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 25kV, No Tilt Mounting.

ABB Installation Products J4-6226-25 4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing…

UPC: 783786241576


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB J4-6226-25 is a 25kV voltage class, 4-point molded multipoint junction designed for medium-voltage power distribution. This unit features a fully shielded, fully submersible molded rubber housing constructed from 100% peroxide-cured EPDM insulation and conductive materials. It provides mating for both 600 Amp and 200 Amp Elastimold Elbow connectors, increasing flexibility and operative ability by saving space in crucial areas. The junction box includes one 200 Amp bushing well interface and two 600 Amp bushing interfaces, with no tilt mounting bracket included. Engineered to meet ANSI/IEEE Standard 386, the J4-6226-25 offers robust performance specifications for the 25kV voltage class: 16.2kV maximum phase-to-ground operating voltage, 140kV BIL impulse withstand (1.2 x 50 microsecond wave), 45kV AC one-minute withstand, and 84kV DC 15-minute withstand. It supports 600 Amp continuous operation with a 25kA Sym momentary and fault close rating for 10 cycles, or 200 Amp continuous operation with a 10kA Sym rating for 10 cycles. Applications for this junction include subsurface, vault, or padmount installations for sectionalizing, looping, tapping, and equipment bypass. The modular design allows for customization of interface combinations. Brackets are constructed from 304 stainless steel to prevent rusting and corrosion. The SKU J4-6226-25 signifies a 4-point junction, with 200 Amp deepwell interfaces (indicated by '2') and 600 Amp bushing interfaces (indicated by '6') on specific ways, a 25kV voltage class, and no tilt mounting bracket (indicated by blank option).
  • 25kV Voltage Class, 4-Point Molded Multipoint Junction
  • Includes one 200 Amp Bushing Well Interface and two 600 Amp Bushing Interfaces
  • Fully shielded, fully submersible molded rubber housing
  • Meets ANSI/IEEE Standard 386 with 140kV BIL and 45kV AC withstand
  • Supports 600A continuous operation (25kA Sym fault close) or 200A continuous (10kA Sym fault close)

Specifications

Application
Suited for Subsurface, Vault or Padmount Applications and can be used for Sectionalizing, Looping, Tapping and Equipment Bypass
Connection
Push-In
Connection Type
Bushing Well
Current Rating
200 A / 600 A
Material
Aluminum
Material
EPDM-Rubber and Stainless Steel Mounting Brackets
Mounting
No Tilt Mounting Bracket
Mounting Type
No Tilt Mounting
Size
Overall Length 23 inches, Width 6-3/4 inches
Special Features
4 inch Center Spacing
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Multi-Point Junction - 4 Points
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
20.5700 L
Package Weight (Metric)
9.3310 kg
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 15kV, No Tilt Mounting.

J4-6226-15

4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 15kV, No Tilt Mounting.
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 25kV, Right Parking Stand.

J4-6226-25-R

4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 25kV, Right Parking Stand.
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 25kV, No Parking Stand.

J4-6226-25-N

4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 25kV, No Parking Stand.
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 15kV, Tilt Mounting Adapter.

J4-6226-15-TMA

4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 15kV, Tilt Mounting Adapter.
Multi-Point Junction - 5 Points. 15kv, (5) 200-Amp Bushing Well Interfaces. Any Customer Modification - CS1185 - 600/200 Amp junction with short bracket, no parking stands and bushing inserts installed. (1601A4(1) inserts installed).

J5-22222-15-CS1185

Multi-Point Junction - 5 Points. 15kv, (5) 200-Amp Bushing Well Interfaces. Any Customer Modification - CS1185 - 600/200 Amp junction with short bracket, no parking stands and bushing inserts installed. (1601A4(1) inserts installed).
3 Point Junction, with one 200 Amp Bushing Well Interface and two 600 Amp Bushing Interface, 25kV, No Parking Stand.

J3-266-25-N

3 Point Junction, with one 200 Amp Bushing Well Interface and two 600 Amp Bushing Interface, 25kV, No Parking Stand.
3 Point Junction, with two 200 Amp Bushing Well Interfaces and one 600 Amp Bushing Interface, 35kV, No Tilt Mounting.

J3-226-35

3 Point Junction, with two 200 Amp Bushing Well Interfaces and one 600 Amp Bushing Interface, 35kV, No Tilt Mounting.
3 Point Junction, with one 600 Amp Bushing Interface, one 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 15kV, No Parking Stand.

J3-626-15-N

3 Point Junction, with one 600 Amp Bushing Interface, one 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 15kV, No Parking Stand.

Frequently Asked Questions

What voltage classes do the junctions support?

The junctions support 15kV, 25kV, and 35kV voltage classes.

Which industry standard do these junctions meet?

The junctions meet ANSI/IEEE Standard 386, Latest Revision.

What is the maximum operating voltage for a 35kV class junction?

For the 35kV voltage class, the maximum phase-to-ground operating voltage is 21.1kV.

What is the maximum operating voltage for a 25kV class junction?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV.

What is the maximum operating voltage for a 15kV class junction?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.

What connectors are compatible with these junctions?

The junctions provide mating for Elastimold Elbow connectors, both 600 Amp and 200 Amp.

What are the primary applications for these junctions?

These junctions can be used for sectionalizing, looping, tapping, and equipment bypass.

Where can ELASTIMOLD junctions be installed?

ELASTIMOLD junctions are designed for subsurface, vault, or padmount applications.

What continuous current ratings are available?

The junctions are available with continuous current ratings of either 200 Amp or 600 Amp.

What interface spacing options are available?

The junctions are available with standard 4-inch spacing or an optional 6.5-inch spacing.

How to Install the J4-6226-25 Deadbreak Junction (Universal Mount)

This guide provides step-by-step instructions for installing the J4-6226-25 four-point deadbreak junction using the universal mount method. It covers mounting, grounding, and initial preparation for interfacing with ELASTIMOLD deadbreak connectors.

Estimated time: 1h

Tools needed:

Wrench set, Wire strippers, Multimeter

Supplies needed:

Suitable fasteners, Grounding wire (No. 2 solid to 1/0 stranded), ELASTIMOLD approved lubricant, HV insulated caps

  1. Ensure De-energization and Inspect Parts

    DANGER: All apparatus must be de-energized during installation or removal of parts. Verify the circuit is de-energized using appropriate safety procedures and equipment. Inspect all junction parts for damage, correct rating, and compatibility with mating parts before beginning installation. Failure to follow these instructions will result in damage to the product and serious or fatal injury.

  2. Prepare Mounting Location

    Determine the desired location for the junction assembly on a flat surface. Use the base plate as a template to mark the four slot locations on the mounting surface.

  3. Mount Initial Universal Brackets

    Attach two (2) universal brackets to the marked slot locations on the flat surface using suitable fasteners. Tighten these fasteners securely to prevent any movement during operation.

  4. Assemble Remaining Universal Brackets

    Attach the remaining two (2) universal brackets to the two brackets already mounted on the surface. Position them at the desired angle using the supplied 3/8” hex head cap screws, external tooth lock washers, and 3/8” hex nuts. Tighten securely.

  5. Assemble Junction to Base Bracket and Plate

    Assemble the deadbreak junction to the base bracket assembly and base plate. Use the supplied two (2) 1/2” hex head cap screws, two (2) 1/2” split lock washers, and two (2) 1/2” hex nuts, attaching them to the center mounting holes on the bracket assembly. Tighten securely.

  6. Attach Junction Assembly to Universal Brackets

    Attach the complete deadbreak junction assembly (with base bracket and plate) to the universal brackets using the supplied 1/2” hex head cap screws, 1/2” split lock washers, and 1/2” hex nuts. Ensure the parking stand is in the upright position and tighten all hardware securely.

  7. Ground the Junction Assembly

    The base bracket assembly and the junction’s black conductive jacket must be grounded. Connect a grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket for this purpose. Ensure a secure and reliable ground connection.

  8. Prepare Operating Interfaces

    Remove all protective shipping caps from the operating interfaces. Clean each interface thoroughly and lubricate them with an ELASTIMOLD approved lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful to the product or its mating components.

  9. Install Insulated Caps on Unused Bushings

    If not all operating interfaces will be utilized, install appropriate HV insulated caps on any unused bushing(s) before energizing the circuit. Do not use the protective shipping caps for this function, as they are not insulated.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.