Contact for Pricing
Overview
- 25kV voltage rating for medium-voltage applications
- One 200 Amp and two 600 Amp bushing well interfaces
- Right parking stand for secure installation and maintenance
- Designed for utility, industrial, and commercial power distribution
- Manufacturer: ABB - Installation Products, SKU: J4-6226-25-R
Specifications
Application | Suited for Subsurface, Vault or Padmount Applications and can be used for Sectionalizing, Looping, Tapping and Equipment Bypass |
Connection | Push-In |
Current Rating | 200A, 600A, 200A |
Material | EPDM-Rubber and Stainless Steel Mounting Brackets |
Mounting | Right Parking Stand |
Size | Overall Length 20.5 inches, Width 6.75 inches |
Special Features | 4 inch Center Spacing |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Multi-Point Junction - 4 Points |
Voltage Rating | 25kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

J6-622226-25
6 Point Junction, with one 600 Amp Bushing Interfaces, four 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, No Tilt Mounting.
J4-6226-25-N
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 25kV, No Parking Stand.
J4-6226-15
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 15kV, No Tilt Mounting.
J4-6226-15-TMA
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 15kV, Tilt Mounting Adapter.
J5-22222-15-CS1185
Multi-Point Junction - 5 Points. 15kv, (5) 200-Amp Bushing Well Interfaces. Any Customer Modification - CS1185 - 600/200 Amp junction with short bracket, no parking stands and bushing inserts installed. (1601A4(1) inserts installed).
J3-266-25-N
3 Point Junction, with one 200 Amp Bushing Well Interface and two 600 Amp Bushing Interface, 25kV, No Parking Stand.
J3-226-35
3 Point Junction, with two 200 Amp Bushing Well Interfaces and one 600 Amp Bushing Interface, 35kV, No Tilt Mounting.
J3-626-15-N
3 Point Junction, with one 600 Amp Bushing Interface, one 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 15kV, No Parking Stand.Frequently Asked Questions
What are the voltage classes for this junction?
The multipoint junctions are available for 15kV, 25kV, and 35kV voltage classes.
What is the maximum operating voltage for a 25kV class junction?
For a 25kV voltage class junction, the maximum phase-to-ground operating voltage is 16.2kV.
How many points can the junction have?
The junction can be configured with 2, 3, 4, 5, or 6 points.
What are the available interface types for the junction?
The junction supports 200 Amp deepwell interfaces and 600 Amp bushing interfaces. Blank positions are also an option.
What is included in a standard junction kit?
Each kit contains a basic molded junction, mounting hardware, two tubes of lubricant, installation instructions, and a protective cap.
What is the maximum operating voltage for a 35kV class junction?
For a 35kV voltage class junction, the maximum phase-to-ground operating voltage is 21.1kV.
What is the maximum operating voltage for a 15kV class junction?
For a 15kV voltage class junction, the maximum phase-to-ground operating voltage is 8.3kV.
What types of connectors are compatible with this junction?
The junction provides mating for Elastimold Elbow connectors, both 600 Amp and 200 Amp.
What are the available interface spacing options?
The junctions offer standard 4-inch spacing or an optional 6.5-inch spacing for interfaces.
Where can these multipoint junctions be installed?
ELASTIMOLD junctions are designed for subsurface, vault, or padmount applications.
How to Install a J4-6226-25-R Four-Point Deadbreak Junction (Universal Mount)
This guide provides step-by-step instructions for installing a J4-6226-25-R four-point deadbreak junction using the universal mount method, including mounting, assembly, grounding, and initial setup. Ensure all apparatus is de-energized before beginning installation.
Estimated time: 1h
Tools needed:
Wrench set (for 3/8" and 1/2" hex nuts/screws), Drill (if mounting surface not pre-drilled), Wire strippers, Measuring tape or ruler, Marking tool (pencil or marker)
Supplies needed:
J4-6226-25-R Deadbreak Junction, Mounting Hardware Prepack (includes base bracket, base plate, universal brackets, and associated fasteners), Suitable fasteners (user-supplied, for attaching universal brackets to mounting surface), Grounding wire (No. 2 solid to 1/0 stranded), ELASTIMOLD approved lubricant, Insulated caps (for unused bushings, if applicable)
- Ensure Safety and Determine Mounting Location
DANGER: All apparatus must be de-energized during installation or removal of parts. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Determine the desired location for the junction assembly. Use the base plate as a template, place it on the mounting surface, and mark all slot locations.
- Attach Initial Universal Brackets to Surface
Attach two (2) universal brackets to the flat mounting surface using suitable fasteners (supplied by user). Tighten these fasteners securely to prevent any movement during operation.
- Attach Remaining Universal Brackets
Attach the remaining two (2) universal brackets to the two (2) universal brackets already mounted on the surface. Position them at the desired angle using the supplied 3/8" hex head cap screws, external tooth lock washers, and 3/8" hex nuts. Tighten securely.
- Assemble Junction to Base Bracket and Base Plate
Assemble the deadbreak junction to the base bracket assembly and base plate. Use two (2) 1/2" hex head cap screws, two (2) 1/2" split lock washers, and two (2) 1/2" hex nuts, attaching them to the center mounting holes on the bracket assembly. Tighten all components securely.
- Attach Junction Assembly to Universal Brackets
Attach the fully assembled deadbreak junction to the universal brackets using the supplied 1/2" split lock washers, 1/2" hex nuts, and 1/2" hex head cap screws. Tighten securely. Ensure the parking stand is in the upright position.
- Ground the Assembly
The base bracket assembly and the junction's black conductive jacket must be grounded. Connect a grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket. Ensure a secure connection to an appropriate earth ground.
- Prepare Operating Interfaces
Remove all protective shipping caps from the operating interfaces. Clean each interface thoroughly and lubricate them with an ELASTIMOLD approved lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful to this product or its mating product(s).
- Install Insulated Caps (if applicable)
If not all operating interfaces will be utilized, install appropriate HV insulated caps on any unused bushing(s) before energizing the circuit. Do not use the protective shipping caps for this function, as they are not insulated.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.