ABB Installation Products FYC 2/0 Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with…
UPC: 783786727551
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Fused disconnect functionality for circuit protection and isolation in outdoor lighting systems
- Supports 2/0 AWG stranded copper conductors for run and tap connections
- Includes crimped lug connectors for secure, permanent wire termination
- Includes dies for installation: 9/16 inch, 13 mm, TS, and 45
- Y-type configuration for single incoming run to fused branch circuit
Specifications
Amperage Rating | 30 A |
Application | Rated 600V, 30 Amps Maximum, perfect for heavy-duty applications |
Color | Black |
Conductor Range | 2/0 STR AWG |
Connection | Compression |
Connection Type | Crimped Lug Connectors |
Environmental Conditions | WaterTight |
Insulation | True |
Length | 9-3/4 in |
Material | Copper |
Material | Aluminum and Copper, EPDM-Rubber Housing |
Number of Conductors | 3 |
Series | Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type |
Series | Flood-Seal |
Size | 2/0 AWG |
Special Features | EPDM Flood-Seal Housing ensures a fully insulated, watertight, and submersible connection. Safe separations to ensure fuse or connecting link stays in load side when separated. Dual-Rated. Approved for a wide range of aluminum or copper connections |
Type | Break-Away Streetlight Kits |
Voltage Rating | 600V |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

FYA 2/0
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, fused, wire size stranded 2/0, aluminum run copper tap fused, installing dies 58,297,245,5/8-1
FYC 6
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, fused, wire size stranded 6 ,copper run, copper tap fused, installing dies J,7,TE,24
FYC 1/0
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, fused, wire size stranded 1/0, copper run ,copper tap fused, installing dies 1/2,12,TQ,42
FYC 1
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, fused, wire size stranded 1 copper run ,copper tap fused, installing dies 3/8,11K,TB,37
FYC 2
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, fused, wire size stranded 2, copper run, copper tap fused, installing dies 3/8,10,TL-TN,33
FYC 8
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, fused, wire size stranded 8 ,aluminum run copper tap fused, installing dies 1/4,6,TC,21How to Install the FYC/DYC Street Lighting Kit
This guide provides step-by-step instructions for the assembly and wiring of the FYC/DYC (copper) or FYA/DYA (aluminum) street lighting kit. Ensure power is disconnected and installation is performed by a qualified electrician in accordance with national and local electrical codes.
Estimated time: 1h
Tools needed:
Measuring tool, Wire strippers, Crimping tool (with appropriate dies from Table 2), Wood dowel, Wire brush (for aluminum cable/lugs), Wrench or socket (for bolted assembly)
Supplies needed:
Load side cable, Run connection cable, Lubricant, Fuse (13/32" x 1 1/2", 600V 30A max, non-glass body) or Connecting link, Nut, Bolt, Belleville washers, Lugs, HM53 inhibitor or equivalent (for aluminum cable/lugs)
- Prepare Load Side Housing
Measure the cable diameter. Refer to Table 1 in the documentation to select the corresponding section on the load side (plug) housing. Cut off the remaining sections of the housing to the size referenced in the Range column of Table 1.
- Prepare Load Side Cable
Thoroughly clean approximately 8 inches along the load side cable end. Apply lubricant and insert the cable through the small hole in the load side (plug) housing. Push the cable through a sufficient distance to permit 3/8 inch for stripping of insulation. Strip the insulation a distance of 3/8 inch as shown in the documentation.
- Crimp Fuse Holder to Cable
Insert the stripped cable into the crimp barrel of the fuse holder. Crimp the cable into the fuse holder. Refer to Table 2 in the documentation for suggested tool and die types based on conductor size.
- Assemble Fuse Holder into Load Side Housing
Apply lubricant lightly to the outside of the fuse holder. Place the wood dowel into the socket and position the free end of the dowel against a firm surface. Push the load side (plug) housing forward until the fuse holder snaps into position. Wipe off any excess lubricant.
- Insert Fuse or Connecting Link
Insert a 13/32 inch by 1 1/2 inch fuse (600 Volt 30 Amp max.) or a connecting link into the load side (plug) housing. WARNING: DO NOT use a glass body fuse.
- Prepare Y-Type Housing and Run Cable
For run connection: Select and cut the correct cut-off ring on the Y-Type housing for the cable being used. Cut and bevel the cable insulation. Apply lubricant to the end of the cable and the cut opening of the housing. Slide the cable through until it extends 2 to 3 inches beyond the housing. Strip the insulation to fit compression lugs. CAUTION: Do not over strip.
- Crimp Lugs and Prepare for Aluminum (if applicable)
Crimp the lugs with the proper crimping tool. Ensure the pad portions of the lugs are back to back. For aluminum only: Wire brush the pads of the lugs, apply HM53 inhibitor or equivalent on pads, and wipe off any excess inhibitor.
- Assemble and Tighten Bolted Assembly
Assemble the insert using the provided nut, bolt, Belleville washers, and lugs as shown in the illustration. Tighten the bolted assembly securely.
- Assemble Insert in Y-Type Housing
Apply lubricant as shown in the documentation. Slide the Y-Type housing up to the bottom of the line end insert. Push the line end insert into the opening of the Y-Type housing. While pulling on the cables and holding onto the Y-Type housing, slide the housing toward the line end insert. Push the line end insert until it is fully seated in the housing.
- Final Connection of Load Side to Line End
Lubricate the male and female components. Insert the load side (plug) housing, with the installed link or fuse clip, into the line end insert until it is securely connected.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.