Contact for Pricing
Overview
- Durable galvanized steel construction for corrosion resistance
- 3-inch drill size and 16-inch length for ample wiring space
- Includes 1/2-inch and 3/4-inch knockouts for conduit flexibility
- 7-inch diameter brown non-metallic cover for a flush finish
- Ideal for commercial and industrial electrical installations
Specifications
Application | For above-grade, fire rated concrete floors |
Color | Brown |
Knockouts | True |
Material | Phenolic/Galvanized Steel |
Special Features | Provides an economical solution for installing a duplex receptacle in an existing floor |
Standard | UL E2969 |
Standard | UL E2969 / UL E2969 |
Type | Poke Through Systems |
Package Dimensions (L x W x H) | 17.25 IN x 5.5 IN x 5.75 IN |
Package Dimensions (L x W x H) | 43.815 cm x 13.97 cm x 14.605 cm |
Package Weight (Imperial) | 4.250 L |
Package Weight (Metric) | 1.928 kg |

FPT442-SW-BRN
Poke-Through Cover, 7 Inch Diameter with 1/2 Inch and 3/4 Inch Threaded Hubs, Non-Metallic with Brown Finish.
FPT442-SW-BLK
Poke-Through Cover, 7 Inch Diameter with 1/2 Inch and 3/4 Inch Threaded Hubs, Non-Metallic with Black Finish
FPT448-SW-GRY
Poke-Through Furniture Feed Base Unit, 3 Inch Drill Size, 16 Inch Length, 1/2 Inch and 3/4 Inch Knockouts, Galvanized Steel, with Gray Non-Metallic Cover with 7 Inch Diameter
FPT445-SW-IVY
Poke-Through Flush Base Unit, 3 Inch Drill Size, 16 Inch Length, 1/2 Inch and 3/4 Inch Knockouts, Galvanized Steel, with Ivy Non-Metallic Cover with 7 Inch Diameter
FPT421
Poke-Through Pedestal, 3 Inch Drill Size, Height 2-5/8 Inches x Width 4 Inches x Depth 4-7/8 Inches, Accepts 4 Device Plates
FFPT4-C
Furniture Feed Poke-Through Base Unit with (2) conduit hubs-3/4 Inch. for power and 1-1/4 Inch. for communications.
FPT3-2P-2C
Poke-Through Base Unit, 3 Inch Drill Size, 16-1/4 Inch Length, 1/2 Inch and 3/4 Inch Knockouts, Galvanized Steel, with 1 20A Duplex Receptacle and 2 Data JacksFrequently Asked Questions
What is the core drill size for FPT445-SW-BRN?
The core drill size for the FPT445-SW-BRN is 3 inches.
What finishes are available for FPT445-SW-BRN?
The FPT445-SW-BRN is available with a brown non-metallic cover finish.
What materials are used in FPT445-SW-BRN?
The FPT445-SW-BRN features a base made of die-cast zinc and galvanized steel, with a cover available in solid aluminum.
What type of receptacle does FPT445-SW-BRN include?
The FPT445-SW-BRN includes a 20 A duplex receptacle, pre-wired with pigtail ends in a junction box.
What is the capacity of the FPT445-SW-BRN?
The FPT445-SW-BRN has a capacity of 1 duplex receptacle and 2 data jacks.
What is the maximum allowable copper area for communications?
The maximum allowable copper cross-sectional area for communications cabling in the FPT445-SW-BRN is 0.01536 sq. in.
What is the purpose of the junction box in FPT445-SW-BRN?
The junction box in the FPT445-SW-BRN features (5) 1/2" and (5) 3/4" knockouts for wiring connections.
What is the installation spacing requirement?
The installation spacing for the FPT445-SW-BRN requires a minimum of 2 feet on center.
How many poke-throughs can be installed per floor area?
There should not be more than one poke-through per 65 sq. ft. of floor area in each span.
Are there any safety warnings for FPT445-SW-BRN?
Safety warnings include ensuring proper installation to prevent electrical hazards and following local electrical codes.
How to Install the FPT445-SW-BRN Poke-Through Fitting
This guide provides step-by-step instructions for installing the FPT445-SW-BRN poke-through fitting, ensuring proper wiring and sealing for electrical and data connections.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Pliers, Multimeter
Supplies needed:
Mounting screws, Putty, Silicone sealant, Gasket, Grommet
- Prepare the Installation Site
Ensure that all electrical power is disconnected. Core a 3" diameter hole through the floor and insert the through-floor fitting, making sure the locating bracket is flush with the concrete floor.
- Feed Wires and Secure the Fitting
Feed the power wires into the power side of the poke-through, leaving a maximum of 4" of wire above the floor. Fill the inside of the poke-through device with the supplied putty around all wires and attach the device to the mounting plate.
- Install the Power Divider and Tele/Data Cables
Hook the tele/data cables around the notch in the poke-through device. Insert the power divider into the top of the poke-through device, ensuring that power wires are separated from tele/data cables.
- Attach the Mounting Plate
Replace the 1/4" thick carpet and cut a 5-1/4" hole in the carpet over the poke-through. Feed the tele/data cables into the mounting plate and attach the mounting plate to the poke-through with the provided screws.
- Seal and Secure the Cover
Install the gasket between the cover and base plate. If tele/data cables are used, cut holes in the gasket for the cables. Attach the cover to the base plate with the provided screws, ensuring a maximum torque of 8 lbs.-in.
- Apply Sealant for Water Exclusion
Apply a continuous bead of silicone sealant around the mounting plate underneath the base plate to ensure scrub-water exclusion. Attach the base plate to the mounting plate with the furnished screws.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.