UPC: 783786717682
Documents & Media
Contact for Pricing
Minimum Qty: 25
Multiplier: 25
*Contact for lower quantities*
Overview
- Y-Type Mechanical Fuse and Disconnect Kit
- Non-fused design for specific applications
- Crimped lug connectors for secure termination
- Accommodates stranded copper wire size 2 AWG run
- Includes specific installing dies (3/8, 10, TL-TN, 33)
Specifications
Amperage Rating | 30 A |
Application | Rated 600V, 30 Amps Maximum, perfect for heavy-duty applications |
Color | Black |
Conductor Range | #2 Copper AWG |
Connection | Compression |
Environmental Conditions | WaterTight |
Insulation | True |
Length | 9-3/4 in |
Material | Copper Connector, EPDM-Rubber Housing |
Number of Conductors | 3 |
Special Features | EPDM Flood-Seal Housing ensures a fully insulated, watertight, and submersible connection. Safe separations to ensure fuse or connecting link stays in load side when separated. Dual-Rated. Approved for a wide range of aluminum or copper connections |
Type | Break-Away Streetlight Kits |
Voltage Rating | 600V |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.5800 L |
Package Weight (Metric) | 0.2630 kg |

1SNK705010R0000
Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.
ACS380-040S-07A2-4
ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module
XT2NU3090BFF000XXX
C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A
NNC75X75WH2
The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.Frequently Asked Questions
What type of connector does the ABB DYC 2 kit use?
The ABB DYC 2 kit features crimped lug connectors for secure wire termination.
What wire size is compatible with the ABB DYC 2 run conductor?
The ABB DYC 2 kit is designed for stranded copper wire size 2 AWG for the run conductor.
Is the ABB DYC 2 kit fused or non-fused?
The ABB DYC 2 kit is a non-fused mechanical fuse and disconnect kit.
What are the included installing dies for the DYC 2 kit?
The ABB DYC 2 kit includes installing dies 3/8, 10, TL-TN, and 33.
What is the intended application for the ABB DYC 2 kit?
The ABB DYC 2 kit is designed for street and highway lighting applications.
How to Install the DYC/DYA Street Lighting Kit
This guide provides step-by-step instructions for the safe and proper installation of the DYC (copper) or DYA (aluminum) Y-Type street lighting kit, including cable preparation, component assembly, and wiring connections. CAUTION: Product must be installed by a qualified electrician in accordance with national and local electrical codes. Identify LINE and LOAD sides of wiring and molded connector bodies before beginning installation.
Estimated time: 1h 30m
Tools needed:
Measuring tool, Cable cutting tool, Wire strippers, Crimping tool (e.g., T&B WT111M or TBM45S with appropriate die), Wood dowel, Wire brush (for aluminum installations)
Supplies needed:
Y-Type housing (A), Load side (Plug) housing (B), Line end insert (C), Fuse holder (D), Connecting link (E) (DYA & DYC only), Fuse (F) (13/32 inch x 1 1/2 inch, 600 Volt 30 Amp max, not included), 1 Nut, 1 Bolt, 2 Belleville washers & 2 Lugs (G), Lubricant, Load side cable, Run connection cable, HM53 inhibitor or equivalent (for aluminum installations)
- Prepare Load Side Housing
WARNING: Risk of shock, disconnect power before installation. Measure the cable diameter. Refer to Table 1 in the documentation and select the corresponding section on the load side (plug) housing. Cut off the remaining sections of the housing to match the size referenced in the Range column.
- Prepare Load Side Cable
Thoroughly clean approximately 8 inches along the load side cable end. Apply lubricant and insert the cable through the small hole in the load side (plug) housing. Push the cable through a sufficient distance to permit 3/8 inch for stripping of insulation. Strip the insulation a distance of 3/8 inch. CAUTION: Do not over strip.
- Crimp Fuse Holder to Cable
Insert the stripped cable into the crimp barrel of the fuse holder. Crimp the connection using a suitable crimping tool and die, referring to Table 2 in the documentation for suggested tools and dies based on conductor size.
- Assemble Fuse Holder into Load Side Housing
Apply lubricant lightly to the outside of the fuse holder. Place the wood dowel into the fuse holder socket and position the free end of the dowel against a firm surface. Push the load side (plug) housing forward until the fuse holder snaps into its locked position. Wipe off any excess lubricant.
- Insert Fuse or Connecting Link
Insert a 13/32 inch by 1 1/2 inch fuse (600 Volt 30 Amp maximum) or the connecting link (E) into the load side (plug) housing. WARNING: DO NOT use a glass body fuse.
- Prepare Y-Type Housing and Run Cable (for run connection)
For a run connection, select and cut the correct cut-off ring on the Y-Type housing (A) for the cable being used. Cut and bevel the cable insulation. Apply lubricant to the end of the cable and the cut opening of the housing. Slide the cable through until it extends 2 to 3 inches beyond the housing. Strip the insulation to fit the compression lugs.
- Crimp Lugs and Apply Inhibitor (if aluminum)
Crimp the lugs onto the stripped cable ends using a proper crimping tool, ensuring the pad portions of the lugs are back to back. If using aluminum cable, wire brush the pads of the lugs, then apply HM53 inhibitor or an equivalent product to the pads. Wipe off any excess inhibitor.
- Assemble Line End Insert
Assemble the line end insert (C) as shown in the illustration. Tighten the bolted assembly (G) securely.
- Assemble Line End Insert into Y-Type Housing
Apply lubricant to the line end insert as shown in the illustration. Slide the Y-Type housing (A) up to the bottom of the line end insert. Push the line end insert into the opening of the Y-Type housing. While pulling on the cables and holding onto the Y-Type housing, slide the housing toward the line end insert. Push the line end insert until it is fully seated in the housing.
- Connect Load Side to Line End
Lubricate both the male and female components of the connection. Insert the load side (plug) housing (B), which contains the installed link or fuse clip, into the line end insert (C).
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.